'14•SRK-T-164
1. SPECIFICATIONS
Model
Item
SRK21CNS-S6
Indoor unit
SRK21CNS-S6
Outdoor unit
SRC21CNS-S6
Cooling capacity (1)
W
5300
Power supply
1 Phase, 220-240V, 50Hz
Operation
data (1)
Power
consumption
Cooling
kW
1.46
Running
current
Cooling
A
6.4
Inrush current
3.6
COP
Cooling
3.63
Noise
level
Cooling
Sound level
dB(A)
Hi : 47 Me : 42 Lo : 39
50
Power level
dB
60
65
Exterior dimensions (Height x Width x Depth)
mm
309 x 890 x 251
640 x 850 (+65) x 290
Exterior appearance
(Munsell color)
Fine snow
(8.0Y 9.3/0.1) near equivalent
Stucco white
(4.2Y 7.5/1.1) near equivalent
Net weight
kg
12
44.5
Refrigerant
equipment
Compressor type & Q'ty
—
PA190M2AS-4KTL1 (Rotary type) x 1
Motor (Starting method)
kW
—
PSC
Refrigerant oil
0.62 (ESTER OIL VG74)
Refrigerant (4)
kg
R410A 1.34 (Pre-Charged up to the piping length of 7.5m)
Heat exchanger
Louver fins & inner grooved tubing
Louver fins & inner grooved tubing
Refrigerant control
Capillary tubes + Electronic expansion valve
Deice control
Microcomputer control
Air handling
equipment
Fan type & Q'ty
Tangential fan x 1
Propeller fan x 1
Motor
W
30
40
Air flow
Cooling
m
3
/min
15
38
Fresh air intake
Not possible
—
Air filter, Quality / Quantity
Polypropylene net (washable) x 2
—
Shock & vibration absorber
—
Cushion rubber (for compressor)
Operation
control
Operation switch
Wireless remote control
—
Room temperature control
Microcomputer thermostat
—
Operation Display
RUN : Green, TIMER : Yellow, HI POWER : Green,
3D AUTO : Green
Safety devices
Compressor overheat protection,
Frost protection, Serial signal error protection, Fan motor error protection,
Installation
data
Refrigerant piping size (O.D)
mm
Liquid line:
φ
6.35 (1/4") Gas line:
φ
15.88 (5/8")
Connecting method
Flare connecting
Attached length of piping
m
Liquid line : 0.55
Gas line : 0.49
—
Insulation for piping
Necessary (Both sides), independent
Refrigerant line (one way) length
m
Max. 25
Vertical height difference between
outdoor unit and indoor unit
Max.15 (Outdoor unit is higher)
Max.15 (Outdoor unit is lower)
Drain hose
Connectable (VP 16)
—
Power cable
2m (3 Cores wih Earth)
Recommended breaker size
A
20
Connection wiring
Size x Core number
1.5mm
2
x 4 cores (Including earth cable)
Connecting method
Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Option parts
—
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature
Outdoor air temperature
Standards
DB
WB
DB
WB
Cooling
27˚C
19˚C
35˚C
24˚C
ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 230V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 7.5m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is 7.5m to 15m, additional refrigerant is not required.
The pipe length is 7.5m.
Summary of Contents for SRK19CNS-S
Page 2: ......
Page 3: ...14 SRK T 164 TECHNICAL MANUAL...
Page 12: ...10 14 SRK T 164 3 Wireless remote control Unit mm 60 17 3 150 Unit mm 60 17 3 150...
Page 40: ...38 14 SRK T 164 4 Troubleshooting procedure If the air conditioner runs NO YES 39...
Page 48: ...46 14 SRK T 164...
Page 53: ...51 14 SRK T 164 MEMO...
Page 59: ...57 14 SRK T 164 MEMO...
Page 62: ...60 14 SRK T 164 CRBE0393 14 2 5 3 6 7 8 9 11 13 4 17 12 15 15 16 15 15 10 1 18 PANEL FAN ASSY...