'14•SRK-T-164
(6)
3D auto operation
(a)
(i)
(ii)
(b)
Cooling
Air flow selection
Operation mode
AUTO
HI
MED
LO
Indoor temp. – Setting temp. >5°C
Indoor temp. – Setting temp. 5°C
HIGH POWER
AUTO
HI
MED
LO
<=
Flap
Louver
Cooling
Up/down Swing
Wide (Fixed)
Flap
Louver
Cooling
Left/right Swing
Horizontal blowing (Fixed)
Flap
Louver
Cooling
Up/down Swing
Center (Fixed)
Wide (Fixed)
Flap
Louver
Cooling
Horizontal blowing (Fixed)
Operation mode
Indoor temp. – Setting temp. 2°C
Cooling
Air flow direction contorol
2°C < Indoor temp. – Setting temp. 5°C
Indoor temp. – Setting temp. > 5°C
The control in 4) continues.
Control returns to the control in 2).
Control returns to the control in 1).
<=
<=
Wide (Fixed)
Flap
Louver
Horizontal blowing (Fixed)
1)
2)
3)
4)
5)
3