'09•SRK-DB-087D
5 PIPING SYSTEM
Models SRK20ZJ-S, 25ZJ-S
Model SRK35ZJ-S
Humidity
sensor
(HD)
5. RANGE OF USAGE & LIMITATIONS
SRK10YJV-S, 13YJV-S
Net capacity = Capacity shown on specification
Correction factors as follows.
(1) Coefficient of cooling capacity in relation to temperatures
Cooling
22
20
18
16
14
0.6
0.7
0.8
0.9
1.0
1.2
1.1
1.3
0
-5
-10
-15
Applicable range
Depends on installed situation
24
26
20
25
30
35
40
46
ISO-T1 Standard Condition
Cooling operation
Outdoor air
D
.B
.
temperatur
e
(°C
D
. B
.)
Coefficient of cooling
capacity in
relation to temperature
Indoor air W.B. temperature °C W.B.
+