'09•SRK-DB-087D
(b) Sleep timer operation
(7)
ޓ
Timer operation
(a) Comfortable timer setting (ON timer)
(c) OFF timer operation
(8)
ޓ
Installation location setting
(a) Setting
1) If the air conditioning unit is running, press the ON/OFF button to stop.
2) Press the AIR FLOW
(UP/DOWN) button and the
AIR FLOW
(LEFT/RIGHT) button together for 5 seconds
or more.
3) Setting the air-conditioning installation location.
4) Press the ON/OFF button.
Airflow range
Airflow range
Airflow range
(Left End Installation)
(Center Installation)
(Right End Installation)
(Center Installation)
(Right End Installation) (Left End Installation)
,
27.5
25.5
19.5
18
30
(9) Outline of cooling operation
(a) Operation of major functional components in Cooling mode
(b) Detail of control in each mode (Pattern)
1) Fuzzy operation
During the fuzzy operation, the air flow and the compressor command speed are controlled by calculating the difference
between the room temperature setting correction temperature and the suction air temperature.
ON
OFF
OFF
ON
OFF
(few minutes ON)
OFF
(few minutes ON)
ON
ON
ON
Thermostat ON
Thermostat OFF
Failure
Cooling
Compressor
Indoor fan motor
Outdoor fan motor
20~74rps
20~74rps
20~98rps
20~98rps
20~52rps
20~74rps
20~38rps
20~46rps
Model
Fan speed
SRK10YJV-S
SRK13YJV-S
Auto
MED
HI
LO
(10) Outline of automatic operation
(a) Determination of operation mode
The unit checks the indoor air temperature and the outdoor air temperature, determines the operation mode, and then begins in
the automatic operation.
Dehumidifying
Cooling
Indoor air temperature (˚C)
Outdoor air temperature (˚C)
(b)
The unit checks the temperature every hour after the start of operation and, if the result of check is not same as the previous op-
eration mode, changes the operation mode.
(c)
When the unit is started again within one hour after the stop of automatic operation or when the automatic operation is selected
during cooling or dehumidifying operation, the unit is operated in the previous operation mode.
(d)
Setting temperature can be adjusted within the following range. There is the relationship as shown below between the signals of
the wireless remote controller and the setting temperature.
Signals of wireless remote controller (Display)
–6
–5
–4
–3
–2
–1
±
0
+1
+2
+3
+4
+5
+6
Setting
Cooling
0
0
temperature
Dehumidifying
0
0
Summary of Contents for SRK10YJV-S
Page 2: ...TECHNICAL MANUAL...
Page 9: ...3 Wireless remote controller Unit mm 60 17 3 150...
Page 51: ...49...
Page 52: ...50 PARTS LIST INDOOR UNIT SRK10YJV S SRK13YJV S OUTDOOR UNIT SRC10YJV S SRC13YJV S...
Page 61: ...59 CRBE0294 6 13 11 18 12 15 16 3 17 14 2 4 9 8 7 5 1 8 8 10 PANEL FAN ASSY...
Page 65: ...63 CRBE0294 6 13 11 18 12 15 16 3 17 14 2 4 9 8 7 5 1 8 8 10 PANEL FAN ASSY...
Page 69: ...RESIDENTIAL AIR CONDITIONING TECHNICAL MANUAL PARTS LIST...