8 INSPECTION AND MAINTENANCE
Mitsubishi Diesel Engine S16R & S16R2 OPERATION & MAINTENANCE MANUAL
141
Pub. No. K29001-00320 Revision: 1
Fuel System - Check
• When handling fuel, refer to
• Devices and equipment outside the
scope of our supply are included in the
facility.
For the details, refer to such a
document as the specification sheet
prepared by the generator supplier.
• For the devices and equipment outside
the scope of our supply, refer the
corresponding manual of the generator
and the supplier's operation manual.
Fuel tank - Check and Service
Clean and drain water from the fuel tank.
• The fuel tank is outside the scope of
our supply.
For the details, refer to the
corresponding manual of the generator
and the supplier's operation manual.
■
Fuel Tank - Clean
1
Clean the fuel tank.
2
Refill fuel into the fuel tank, and
bleed the fuel system
■
Fuel Tank - Drain Water
Drain water from the fuel tank.
Keep away from fire, when working
with flammable substances such as
fuel.
* They may cause a fire.
If fuel leaks or splashes out from the
high pressure injection pipe, do not
touch the fuel.
* The fuel injection pipe delivers high pressure
fuel. If the fuel contacts your skin, it goes into
deep skin tissues and may result in gangrene.
Wipe off spilled flammable
substances such as fuel thoroughly
with a waste cloth.
* They may cause a fire.
When discarding a waste cloth used
to wipe off combustible material, put
it into a lidded can and obey the
Waste Management and Public
Cleansing Act to handle it as a special
industrial waste.
* It may cause a fire.
* It could lead to environmental pollution.
* If you violate rules, you may be subject to
penalties.
Tighten the fuel supply valve to the
engine firmly.
* Otherwise, fuel may leak out, which could
cause a fire.
After cleaning the fuel tank, do not
leave the used waste cloth in the fuel
tank.
* Otherwise, it may cause damage to the devices
in the fuel system.
When draining fuel through the drain
cock, always use a container which
can accept all the fuel in the tank.
* Otherwise, the drained fuel will overflow from
the container and may run to outside of the
facility.
* The fuel drained into the container shall be
discarded in accordance with the local laws and
regulations as well as the manufacturer's SDS.
When draining water from the fuel
tank, always use a container which is
suitable for the water quantity.
* Otherwise, the drained water will overflow from
the container and may run to outside of the
facility.
* The water drained into the container is
contaminated with fuel. Discard the water in
accordance with the local laws and regulations
as well as the manufacturer's SDS.
Drain water properly from the fuel
tank.
* If water, dust or other foreign particles are left,
they may mix with fuel, which could cause low
output power or damage to the devices in the
fuel system.