18
9
CONNECTING CABLE
✽
1 : In case that cable with stripe of yellow and green is available.
✽
2 : In the flat cables are connected as this picture, they can be used up to 80m.
✽
3 : In case of regular polarity connection (S1-S2-S3), wire size is 1.5mm
2
.
✽
4 : In case of regular polarity connection (S1-S2-S3).
The cable shall not be lighter than design 245 IEC or 227 IEC.
The cable length may vary depending on the condition of installation, humidity or materials, etc.
Cross section
of cable
Round
2.5
2.5
1.5
2.5
3
3
4
4
(50)
✽
1
(45)
✽
3
60
✽
4
Not
applicable
✽
2
Flat
Flat
Round
Wire size
(mm
2
)
Number
of wires
Clockwise : S1-S2-S3
Clockwise : S1-S2-S3-Open
Connect S1 and S3 to the opposite angle
Not applicable
(Because center wire has no cover finish)
From left to right : S1-Open-S2-S3
Polarity
L(m)
(3C Flat cable
✕
2)
S1 S2 S3
For 220-240V 50Hz
OC294-C-1.qxp 04.10.7 5:11 PM Page 18