10
Single, 50Hz, 220-230-240V
Munsell 3Y 7.8/1.1
Linear Expansion Valve
Hermetic
ANV33FDAMT
Line start
HP switch, LP switch, Discharge thermo
—
Plate fin coil
Propeller fan
o
2
0.060 +0.060
100(3,530)
Reverse cycle
50
52
950(37-3/8)
330+30(13+1-3/16)
1,350(53-1/8)
121(267)
R410A
5.5(12.1)·····RP5, 6VHA
5.0(11.0)·····RP5, 6VHA
1
1.40(MEL56)
9.52(3/8)
15.88(5/8)
Flared
Flared
Max. 30m
Max. 75m
A
kW
W
kW
K
/min(CFM)
dB
dB
mm(in.)
mm(in.)
mm(in.)
kg(lbs)
kg(lbs)
L
mm(in.)
mm(in.)
Power supply (phase, cycle, voltage)
Running current
External finish
Refrigerant control
Compressor
Model
Motor output
Starter type
Protection devices
Crankcase heater
Heat exchanger
Fan
Fan(drive)
o
No.
Fan motor output
Airflow
Defrost method
Noise level
Dimensions
Weight
Refrigerant
Charge
Oil (Model)
Pipe size O.D.
Connection method
Between the indoor &
outdoor unit
Function
Cooling
Heating
W
D
H
Liquid
Gas
Indoor side
Outdoor side
Height difference
Piping length
Notes1. Rating Conditions (ISO T1)
Cooling : Indoor : D.B. 27˚C(80˚F), W.B. 19˚C(66˚F) Outdoor : D.B. 35˚C(95˚F), W.B. 24˚C(75˚F)
Heating : Indoor
: D.B. 20˚C(68˚F)
Outdoor : D.B. 7˚C(45˚F), W.B. 6˚C(43˚F)
Refrigerant piping length (one way) : 5m (16ft)
3. Guaranteed voltage
198~264V, 50Hz
4. Above data based on indicated voltage
Indoor Unit
1 phase 230V 50Hz
Outdoor Unit 1 phase 230V 50Hz
5. Refer to the service manual of indoor unit for tha indoor unit's specifications.
2. Guaranteed operating range
Upper limit
Lower limit
Upper limit
Lower limit
Indoor
D.B. 35˚C, W.B. 22.5˚C
D.B. 19˚C, W.B. 15˚C
D.B. 28˚C
D.B. 17˚C
Outdoor
D.B. 46˚C
D.B. -5˚C
D.B. 21˚C, W.B. 15˚C
D.B. -11˚C, W.B. -12˚C
Cooling
Heating
Service Ref.
Cooling
15.80
2.4
Heating
17.50
Cooling
20.73
2.9
Heating
20.37
OUTDOOR UNIT
REFRIGERANT PIPING
PUHZ-RP6VHA
PUHZ-RP6VHA
1
PUHZ-RP5VHA
PUHZ-RP5VHA
1
OC294-C-1.qxp 04.10.7 5:10 PM Page 10