background image

  300 

300

1000

500 

(1000

)

300

1000 

(1500

)

300 

(500

)

1000 

(1500

)

1000 

(1500

)

1000 

(1500

) 300 

(500

)

500 

(1000

)

400 

(600

) 1000 

(2000

)

  300

1000 

(1500

)

500 

(800

)

150

1000 

(1500

)

400 

(600

)

2000 

(3000

)

300 

(500

)

Fig. 2-5

Fig. 2-6

Fig. 2-7

Fig. 2-8

Fig. 2-9

Fig. 2-10

Fig. 2-11

Fig. 2-12

Fig. 2-13

Fig. 2-14

Fig. 2-15

Fig. 2-16

Fig. 2-17

100 

(200

)

  300

100 

(200

)

150 

(250

)

150 

(250

)

1000 (1500)

300 (500)

300

500 

(1000

)

UNIT : mm

(  ) : HW112/140

W112

Max. 500

Max. 500

Max. 300

LVD.indd   5

2015/06/10   15:20:09

Summary of Contents for PUHZ-HW112YHA

Page 1: ...oor voordat u met het installeren van het buitenapparaat begint Het Engels is het origineel De andere taalversies zijn vertalingen van het origineel MANUAL DE INSTALACI N Para un uso correcto y seguro...

Page 2: ...hock or fire If the air to water heat pump needs to be repaired or moved ask an installer or an authorized technician After installation has been completed make sure that refrigerant does not leak If...

Page 3: ...risk of an electric shock For the power lines use standard cables of sufficient capacity Otherwise it may cause a short circuit overheating or fire When installing the power lines do not apply tensio...

Page 4: ...at right angle to the seasonal wind direction if possible Fig 2 4 B Wind direction A M10 3 8 bolt B Base C As long as possible D Vent E Set deep in the ground F Max 30 G Min 360 430 H Min 10 2 4 NECES...

Page 5: ...t water gauge pressure must be between 0 0 3 MPa Use the inlet water with a temperature lower than 55 C Note The water velocity in pipes should be kept within certain limits of material to avoid erosi...

Page 6: ...3 The figures are NOT always against the ground S3 terminal has 24 VDC against S2 terminal However between S3 and S1 these terminals are NOT electrically insulated by the transformer or other device...

Page 7: ...r the compressor starts to warm up once power is supplied After supplying power for the times indicated below re move the wires from the compressor and measure the insulation resistance again The insu...

Page 8: ...ni ej s przeznaczone do zastosowa w rodowisku mieszkalnym handlowym i lekko uprzemys owionym MITSUBISHI ELECTRIC PUHZ W50VHA2 PUHZ W50VHA2 BS PUHZ W112VHA PUHZ W112VHA BS PUHZ HW112YHA2 PUHZ HW112YHA2...

Page 9: ...wiadcza na swoj wy czn odpowiedzialno e klimatyzatory i pompy ciep a opisane poni ej s przeznaczone do zastosowa w rodowisku mieszkalnym handlowym i lekko uprzemys owionym MITSUBISHI ELECTRIC PUHZ W85...

Page 10: ...anv ndare i aff rer inom l tt industri och p lantbruk eller f r kommersiell anv ndning av lekm n NEDERLANDS Het Engels is het origineel De andere taalversies zijn vertalingen van het origineel VOORZIC...

Page 11: ...obsluhovat laici POLSKI J zykiem orygina u jest j zyk angielski Inne wersje j zykowe stanowi t umacze nie orygina u UWAGA Wyciek czynnika ch odniczego mo e spowodowa uduszenie Nale y zapewni wentylacj...

Page 12: ...1000 2000 300 1000 1500 500 800 150 1000 1500 400 600 2000 3000 300 500 Fig 2 5 Fig 2 6 Fig 2 7 Fig 2 8 Fig 2 9 Fig 2 10 Fig 2 11 Fig 2 12 Fig 2 13 Fig 2 14 Fig 2 15 Fig 2 16 Fig 2 17 100 200 300 100...

Page 13: ...ntact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commercial and light industrial environment The product...