<List of system remote controller functions>
(*1) Refer to page 33.
(*2) This controller (system remote controller) is one of the system controllers.
(*3) Refer to page 29.
(*4) This controller does not have a clock function.
11-2. Main specifications
34
Function
Details
Initial
setting
functions
Operation
Group setting
Prohibit range
Set the unit (indoor unit, LOSSNAY remote controller, slave system controller)
group.
Set interlocking with the LOSSNAY and indoor unit.
Set the set temperature display to a Celsius or Fahrenheit display.
Maximum 50 units (Maximum 50 groups)
Set whether to prohibit operations for the remote control with this
controller.
0 to 16 units (The indoor unit and LOSSNAY cannot be registered
in the same group.)
The current time can be set collectively for system controllers and remote
controls provided with the time setting function.
The set temperature range can be set collectively for remote controls
provided with the set temperature range limit mode function.
Set the system remote controller's own address (Refer to the
Installation Manual.)
Set whether to prohibit operation with the local remote controller using this
controller or with another controller.
Interlocked unit setting
Master system controller
/slave system controller (*1)
Set the system controller as the master or slave.
Prohibit transmission/reception
"Celsius/Fahrenheit" display
0 to 2 units
Number of local remote
controllers in one group
0 to 16
Number of indoor units
linked with one LOSSNAY
System remote
controller own address
Set temperature
range limit mode
System (*3)
Others
Time setting (*4)
Indoor units, LOSSNAY
Number of indoor units and
LOSSNAY
0 to 4 units (Includes the number of local remote controllers for one
group.) 0 to 3 units in group having one local remote controller
Number of system controllers
controlling one group (*2)
System
limits
Number of
registered units
Item
Details
Power source
Power consumption
Working environment conditions
Weight
Outline dimensions
Temperature 0 to 40
o
C / 32 to 104
o
F, humidity 30 to 90%RH (with no dew condensation)
(H
x
W
x
D) 120
x
130
x
18
[mm]
/ 4
3
/
4 x
5
1
/
16 x 3
/
4[in]
1W
0.2
o
30VDC (supplied from indoor unit or power feed unit for transmission line (type: PAC-SC34KUA).
Summary of Contents for PAC-SF44SRA
Page 35: ...35 GB ...
Page 69: ...69 D ...
Page 103: ...103 F ...
Page 137: ...137 E ...
Page 171: ...171 I ...
Page 205: ...205 NL ...
Page 206: ...HEAD OFFICE MITSUBISHI DENKI BLDG 2 2 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN WT03804X01 ...