7-4. STANDARD OPERATION DATA
Capacity
SHF
Input
Rated frequency
Indoor unit
Power supply (V, phase, Hz)
Input
Fan motor current
Aux. heater current
Outdoor unit
Power supply (V, phase, Hz)
Input
Comp. current
Fan motor current
Condensing pressure
Suction pressure
Discharge temperature
Condensing temperature
Suction temperature
Comp. shell bottom temp
Ref. pipe length
Refrigerant charge (R410A)
Intake air temperature
Discharge air temperature
Fan speed (High)
Airflow (High)
Intake air temperature
Fan speed
Airflow
Unit
Btu / h
—
kW
Hz
kW
A
A
kW
A
A
PSIG
PSIG
˚F
˚F
˚F
˚F
ft.
—
˚F
˚F
˚F
˚F
rpm
CFM
˚F
˚F
rpm
CFM
Cooling
9,000
0.71
0.690
50
0.674
2.80 / 2.53
363
144
145
107
55
140
80
67
57
56
1,080
275 (Wet)
95
–
840
1,094
Cooling
12,000
0.70
1,170
76
1.149
5.08 / 4.59
395
124
169
112
54
163
80
67
56
54
1,220
318 (Wet)
95
–
840
1,094
Heating
10,900
–
0.860
61
0.844
3.63 / 3.28
368
109
153
108
37
147
70
60
105
71
1,080
307
47
43
840
1,094
Heating
13,600
–
1,160
76
1.139
5.03 / 4.54
393
103
164
113
35
158
70
60
108
72
1,220
353
47
43
840
1,094
DB
WB
DB
WB
DB
WB
Item
Model
Total
Electrical
circuit
Refrigerant
circuit
Indoor
unit
Outdoor
unit
MSZ-A09NA
MSZ-A09NA
208/230, 1, 60
0.016
0.18 / 0.16
–
MUZ-A09NA
208/230, 1, 60
0.37 / 0.34
25
2lb.5oz.
MSZ-A12NA
MSZ-A12NA
208/230, 1, 60
0.021
0.23 / 0.21
–
MUZ-A12NA
208/230, 1, 60
0.37 / 0.34
25
2lb.5oz.