(1) In any of the following cases, an operation error occurs, the error flag (SM0) turns ON, and an error code is stored into
SD0.
Program
E
xamp
l
e
(1) The following program performs a COS
-1
operation on the sign (positive when X0 is OFF, and negative when X0 is ON),
the BCD 1-digit integer part from X30 to X33 and the BCD 4-digit decimal fraction part from X20 to X2F, and outputs the
calculated angle in 4 BCD digits from Y40 to Y4F.
[Ladder Mode]
[List Mode]
Error
code
Error details
Q00J/
Q00/
Q01
QnH
QnPH QnPRH
QnU
LCPU
4100
The operation data specified in is not a BCD value.
The operation data specified in is not in the range from -1.0000 to
1.0000.
––
4101
The points of the device specified in exceed those of the
corresponding device.
––
––
––
––
S
S
S
Turns M0 ON
w
hen D1>1 or D1=1 and D2 0
Sets the decimal fraction part of a COS
v
alue ( )
Sets the sign of a COS
v
alue ( )
Sets the integer part of a COS
v
alue ( )
Executes COS-1 operation and outputs
the result of operation to Y40 to Y4F ( )
1
2
3
4
Step
I
nstruct
i
on
De
vi
ce