Mitsubishi ME96SSR-MB User Manual Download Page 32

3. Setting

                                                                                                                                         

 

 

3.7 Setting Menu 6: Setting the Analog Output

                                                                                               

 

 

 

 

 

 

 

 

 

 

 

- 31 - 

 

 

According to the setting flow (page 14), save the changed 
contents, or continue to the other setting menu.

 

Setting menu

 

SET

Set analog output for when full scale is over the limit

.

The same in all the CH

) 

Setting value

 

Description

 

oFF 

(No limit)

 

For the span value, the maximum output

 

is +5% and the minimum output is -5%.

 

on 

(Limited)

 

For the span value, the maximum output

 

is +1% and the minimum output is -1%.

 

 
 
 
 
 
 
 
 
 

Note: W hen the output items for all analog output are set to "non," this setting is skipped.

 

Analog output limit

 

20 mA

oFF

:+

5%

on

  :+

1%

oFF

:-

5%

on

  :-

1%

4 mA

Summary of Contents for ME96SSR-MB

Page 1: ...ument Types ME96SSR MB User s Manual Detailed Edition Before operating the instrument you should first read thoroughly this operation manual for safe operation and optimized performance of the product...

Page 2: ...tput Communication ME 4210 SS96 4 circuits 2 points 1 point ME 0040C SS96 4 points CC Link ME 0052 SS96 5 points 2 points Note ME 4201 NS96 ME 0052 NS96 and ME 0040C NS96 can not use in the ME96SSH MB...

Page 3: ...munication CC Link communication are able to transmit the measured data to superior monitoring devices CC Link communication When the ME 0040C SS96 optional plug in module is installed The instruments...

Page 4: ...ting Menu 8 Special Settings Setting Operating Time Phase Display IEC mode 33 3 10Setting Value Confirmation Menus 1 9 Confirming the Settings in the Setting Menus 1 8 and Test Mode in Setting Menu 9...

Page 5: ...peration of digital input output status 57 Releasing the digital input latch 57 Preventing maximum value update by motor starting current 58 Password protection setting 58 6 Other 6 1 Display Pattern...

Page 6: ...ormal service conditions as following points Ambient temperature 5 to 55 C Average day temperature 35 C or less Humidity 0 85 RH non condensing Altitude 2000m or less Pollution Degree 2 or less Note 1...

Page 7: ...w 600V or 600A power lines 30cm or more Other power lines 60cm or more C A U T I O N Matters concerning the precaution before use Use the instrument in the specified usage environment and conditions T...

Page 8: ...tc Repair shall be charged for the following cases even during the gratis warranty period Failures occurring due to your improper storage or handling carelessness or fault Failures due to faulty workm...

Page 9: ...mounted on panel of a cabinet Therefore the construction of a cabinet is important not only for safety but also for EMC The instrument is examined by the following conditions Conductive cabinet is us...

Page 10: ...e 100 or less Operation buttons For details refer to page 11 Current Input terminals C1 C1 Input a circuit current C2 C2 Input a circuit current C3 C3 Input a circuit current Input output terminals ME...

Page 11: ...ated with otherwise indicated with 8 Phase status They show the phase for each of the digital displays 9 Digital display Measured values displayed in digital 10 Unit Units of measuring value displayed...

Page 12: ...ctive in setting backlight flicker Measured value is reset Canceling the alarm etc The latching data of digital input on the display is canceled Available only for contact point input screen The displ...

Page 13: ...he settings to the factory defaults P 13 to P 34 P 36 to P 40 Setting Value confirmation mode Test Mode This mode is for confirming the setting values for each setting item In this mode settings canno...

Page 14: ...et to the default settings Refer to page 36 Frequency Measurement Display Setting Menu End End Display CANCEL Display Automatic migration Cancel the settings Save the setting Instrument restart or Fac...

Page 15: ...go back to the operationmode Press it Select CANCEL or Press it Cancel the settings Press it Skip remaining setting items during setting Press it for 1 second Set values return to the factory default...

Page 16: ...is no display pattern that you want from P01 to P13 select the special display pattern P00 to configure the screen freely For more information about setting the special display pattern P00 refer to p...

Page 17: ...ansformers 1 For direct input without VT Set the direct voltage a For 3 phase 4 wire phase to neutral voltage phase to phase voltage b For 3 phase 3 wire 2CT 3CT or 1 phase 2 wire c For 1 phase 3 wire...

Page 18: ...eview the setting value and set it once Again When over 100V set over upper 3 digits setting the display appear switching upper 3 digits setting Press at the lowest digit the setting step will shift t...

Page 19: ...ot be reset According to the setting flow page 14 save the changed contents or continue to the other setting menu Setting menu Set the time constant for current demmand For the demand time period refe...

Page 20: ...ress number When the CC Link communication is selected in Communication method selection this display will be skipped Selectable addresses 1 to 255 MODBUS RTU address Select either of CC Link communic...

Page 21: ...become effective When the ME 0040C SS96 optional plug in module is not installed or the CC Link communication is not selected in Communication method selection this display will be skipped Communicat...

Page 22: ...SET DISPLAY Set the voltage maximum scale If you have not set voltage to Display pattern this display will be skipped Maximum scale value Voltage maximum scale Note The maximum scale value becomes th...

Page 23: ...ed contents or continue to the other setting menu Setting menu Set the combinations of imported exported and lag lead for active energy and reactive energy you want to display and set the measurement...

Page 24: ...r setting menu Setting menu The display update time for the measured value can be change If the display switches too quickly for you to read the displayed value set it to 1 0 second Normally leave thi...

Page 25: ...ept 3 phase 4 wire Alarm item 1 Note 1 Measurement items that are not selected in the display pattern can be selected Note 2 DA Current demand DAN N phase current demand V L N Phase to neutral voltage...

Page 26: ...pper lower limit alarm for the 12 phase and 13 phase Alarm value 1 SET DISPLAY Set the measurement element assigned to the upper lower limit alarm items 2 to 4 Elements that are set elsewhere cannot b...

Page 27: ...rent value Set the value for detecting the motor starting current Setting range Setting step Note 3 to 5 to 120 1 This is the percentage for the maximum scale value for the current 0 step 2 Motor star...

Page 28: ...below according to total load power kW In the following cases this display will be skipped ME 4210 SS96 optional plug in module is not installed Not set PULSE to Pulse Alarm output 1 Set non to Pulse...

Page 29: ...ditions for the receiver In the following cases this display will be skipped ME 4210 SS96 optional plug in module is not installed Not set PULSE to Pulse Alarm output 1 and Pulse Alarm output 2 Set no...

Page 30: ...A1 Demand AN Demand A2 Demand AAVG V1N CH2 V2N V12 VAVG W CH3 var PF CH4 Hz Harmonic A1 Harmonic A2 Harmonic V1N Harmonic V2N non A1 CH1 AN A3 AAVG Demand A1 Demand AN Demand A3 Demand AAVG V1N CH2 V3...

Page 31: ...or PF are set as output items it moves to the next analog output settings 2 Detailed setting values are according to the values shown in the table on pages 62 to 64 0 STEP 100 Rating 10 STEP About 40...

Page 32: ...for when full scale is over the limit The same in all the CH Setting value Description oFF No limit For the span value the maximum output is 5 and the minimum output is 5 on Limited For the span valu...

Page 33: ...f periodic active energy Non Not switched COM Communication control d in1 Digital input DI1 d in2 Digital input DI2 non COM d in1 d in2 Note When the ME 4210 SS96 optional plug in module is installed...

Page 34: ...Displayed Set the setting menu number to 8 as shown in the right figure Setting menu SET RESET SET DISPLAY SET DISPLAY SET DISPLAY SET DISPLAY Select the target for counting Operation time from the a...

Page 35: ...the setting flow page 14 save the changed contents or continue to the other setting menu Setting menu SET DISPLAY SET Set the mode for reactive power power factor etc arithmetic expression and code t...

Page 36: ...ET The screen transitions and operations are the same as for Setting Menus 1 to 8 Refer to Setting Menus 1 to 8 pages 15 to 34 Note Settings cannot be changed in the Setting value confirmation mode Se...

Page 37: ...shold for counting Operation time Current Maximum minimum value Current demand Maximum minimum value Voltage Maximum minimum value Active power Maximum minimum value Reactive power Maximum minimum val...

Page 38: ...g method DISPLAY Upper stage item 1 Middle stage item 2 Lower stage item 3 Upper stage item 4 Middle stage item 5 Lower stage item 6 Upper stage item 7 Middle stage item 8 Lower stage item 9 Upper sta...

Page 39: ...et to no display automatically SET SET SET SET SET SET SET SET SET SET Returns to the setting for the upper stage of the display 4 1 DISPLAY VT direct voltage hereafter same as the setting menu 1 Note...

Page 40: ...1 and then press S E T Setting menu Press simultaneously for 2seconds RESET SET The factory default setting is 3 phase 4 wire so just press SET Phase wire system SET Setting is P01 so just press SET...

Page 41: ...U baud rates 40 The factory default setting is EVEn even so just press SET MODBUS RTU parity SET The factory default setting is 1 so just press SET MODBUS RTU stop bit SET Set the setting menu number...

Page 42: ...s 4 Analog output operation test For functions with analog output it is possible to confirm analog output operation without measurement voltage current input Use this for confirming connection with th...

Page 43: ...using the ME 4210 SS96 alarm contact will remain open It is possible to monitor the digital input status Display screen Button operation Operation Function Press Switches the display screen Press Swi...

Page 44: ...n to the operation mode Test menu SET SET Execute the alarm output digital output CH2 operation test The test method is the same as Alarm output Digital output CH1 operation test Alarm output Digital...

Page 45: ...adjustment for analog output CH2 to CH4 The adj ustment method is the same as Analog Output CH1 Zero Adj ustment Analog output CH2 to CH4 zero adjustment Execute span adjustment for analog output CH1...

Page 46: ...on test 0 25 50 75 100 Note The analog output item set up with Setting the Analog Output Setting Menu 6 is displayed Upper Analog output 1 Middle value Lower Setting analog output item and the measure...

Page 47: ...End as the test menu number and then press You will return to the operation mode Test menu SET SET SET SET DISPLAY Pulse output CH1 operation test 0 1 2 49 50 pulse RESET RESET Note1 When Pulse Alarm...

Page 48: ...er of screens Screen number display DISPLAY DISPLAY DISPLAY DISPLAY Screen 4 of 4 Upper Current Middle Not displayed Lower N phase current 47 Switch phase By pressing the current phase and the voltage...

Page 49: ...same In the case of 3 measuring items of screen are same the bar graph of average value or total value appear instead of Upper Middle and Lower The bar graph cannot be displayed in the following case...

Page 50: ...re Display Pattern P01 without additional screens DISPLAY Press for 2 seconds Changes automatically Changes automatically Changes automatically Changes automatically Displays for 5 seconds Displays fo...

Page 51: ...current Current total phase 2 3 Current total phase 1 Current 1st phase2 3 Current 1st phase 1 Current 13th phase2 3 Current 13th phase 1 Appears 3rd 5th 7th 9th 11th in order PHASE DISPLAY Harmonic c...

Page 52: ...ethod display pattern setting and additional screens are not displayed Press 3 phase 4 wire A and DA switch as V switches as W var VA PF switch as AN DAN and Hz do not have phase switching 3 phase 3 w...

Page 53: ...ing value of the VT primary voltage and the CT primary current are large the lower digits less than a measurement range display 0 Wh and varh zero reset When and are pressed simultaneously for 2 secon...

Page 54: ...comes 2 quadrant counting regardless of Expanded counting in the Setting Menu 3 If setting of Expanded counting is selected for 4 quadrant counting and setting of IEC mode is ON the screens of exporte...

Page 55: ...I about three times more than the time to is needed The demand value is the measurement display value with the above time characteristics and it shows the overall average within the demand time The d...

Page 56: ...If it does not exist on the display screen it does not flicker Alarm status Digital value Unit Phase Alarm generation Flickering Flickering Flickering Alarm retention On Flickering Flickering Alarm ca...

Page 57: ...output collectively with either of them Pulse output Pulse output No alarm No alarm Display of periodic active energy The ability to measure the active energy divided into two time segments enables i...

Page 58: ...be reset to zero also via communication In this case the password is not necessary RESET Display and operation of digital input output status The digital status can be displayed by inputting the switc...

Page 59: ...you enter the password Default password is 0000 If you enter the wrong password to return to the password input display the highest digit blink By pressing at the highest digit to return to the operat...

Page 60: ...V2N P06 Lower A3 V3N V AN ditto ditto ditto ditto ditto ditto ditto ditto ditto Upper A A1 V1N A Middle V A2 V2N P07 Lower W A3 V3N AN ditto ditto ditto ditto ditto ditto ditto ditto ditto Upper A A A...

Page 61: ...A1 DA1 V12 Middle DA DA A2 DA2 V23 P10 Lower V W A3 DA3 V31 ditto ditto ditto ditto ditto ditto ditto ditto Upper A A DA1 V12 Middle DA V DA2 V23 P11 Lower Wh Wh DA3 V31 Wh Wh Exported ditto ditto dit...

Page 62: ...right Note2 For convenience of scale this is rounded off to the nearest whole number Specific power value for scale calculation Phase line type CT Secondary Rated voltage Specific power value 100 110...

Page 63: ...3 Current maximum scale value 3 3 STEP A unit STEP A unit kA unit STEP kA unit 1 1A 51 180A 101 25kA 2 1 2A 52 200A 102 30kA 3 1 5A 53 220A 103 32kA 4 1 6A 54 240A 104 36kA 5 1 8A 55 250A 105 40kA 6 2...

Page 64: ...800V 109 720kV 10 36V 60 5000V 110 750kV 11 40V 61 6000V 111 800kV 12 45V 62 6400V 112 900kV 13 48V 63 7 2kV 113 960kV 14 50V 64 7 5kV 114 1000kV 15 60V 65 8kV 115 1200kV 16 64V 66 9kV 116 1500kV 17 7...

Page 65: ...kW 166 120MW 17 45W 67 6400W 117 900kW 167 150MW 18 48W 68 7200W 118 960kW 168 160MW 19 50W 69 7500W 119 1000kW 169 180MW 20 60W 70 8000W 120 1200kW 170 200MW 21 64W 71 9kW 121 1500kW 171 220MW 22 72W...

Page 66: ...istortion ratio N phase 1 N phase 2 N phase 3 N phase Primary Max Phase 1 2 phase Primary 2 3 phase Primary Max Primary Max RMS value 3 1 phase 1 N phase Total 2 N phase Total 3 N phase Max Phase Tota...

Page 67: ...e n is 0A or the voltage of phase n is 0V where n 1 2 or 3 When it is over the upper limit of the possible display range 9999 the upper limit of the possible display range 9999 is displayed Power fact...

Page 68: ...nt of the inverter secondary side output Please check the measured item The current measured by another measurement instrument such as a clamp meter is different from the current measured by this inst...

Page 69: ...Installation 1 Dimensions 68 With Optional Plug in Module ME96SSR MB...

Page 70: ...Installation 1 Dimensions Optional Plug in Module ME 4210 SS96 ME 0040C SS96 ME 0052 SS96 69...

Page 71: ...e LCD during mounting of the panel Before starting operation remove the sheet When removing the sheet the LCD may illuminate due to static electricity but this is not a product failure After a while t...

Page 72: ...ditions Single wire AWG22 to 16 Bar terminal can be not used in combination Option terminal Without screw Single wire Stranded wire AWG24 to 14 Stranded wire is bar terminal can be used in combination...

Page 73: ...s to the connection terminals are tight Electrical wires must be properly tightened to the connection terminal Otherwise heat and measurement errors may be caused Do not forget wiring of C1 C2 and C3...

Page 74: ...wire type max AC220V L N 440V L L Figure 4 DELTA max AC220V L L Figure 5 1 phase 2 wire type Note STAR max AC440V L L Figure 6 Note In case of a circuit which is wired from the delta connection of a...

Page 75: ...100 to 240V Fuses 0 5A Note 1 For low voltage circuits grounding the secondary side of VT and CT is not t necessary 3 phase 4 wire type With VT Auxiliary power supply AC100 to 240V or DC100 to 240V Fu...

Page 76: ...voltage circuits grounding the secondary side of VT and CT is not t necessary Note 2 Do not connect to NC terminal 3 phase 3 wire 3CT type With VT Auxiliary power supply AC100 to 240V or DC100 to 240...

Page 77: ...to 240V Fuses 0 5A Note 1 For low voltage circuits grounding the secondary side of CT is not t necessary 1 phase 2 wire type With VT Auxiliary power supply AC100 to 240V or DC100 to 240V Fuses 0 5A N...

Page 78: ...77 Installation 4 Wiring Diagram Optional Plug in Module ME 4210 SS96 Optional Plug in Module ME 0040C SS96 Optional Plug in Module ME 0052 SS96...

Page 79: ...ends of the MODBUS RTU link the 120 ohm resistance has to be attached This instrument can perform a 120 ohm termination by short circuiting the terminal of T R and Ter 3 The earthing has to be connect...

Page 80: ...r of display digits A DA V W var VA PF 4 digits Hz 3 digits Wh varh 9 digits 6 digits or 12 digits possible Harmonic total distortion ratio 3 digits Harmonic RMS value 4 digits Operation time 6 digits...

Page 81: ...MB ME96SSH MB ME96SSR MB ME96SSE MB Interface specifications LSPM 0075 4 Precautions for CC Link Communication Item Specifications CC Link station type Remote device station ver 1 remote device statio...

Page 82: ...2 non 5 2 1 Alarm value 2 5 3 Alarm item 3 non 5 3 1 Alarm value 3 5 4 Alarm item 4 non 5 4 1 Alarm value 4 5 5 Alarm delay time 5 6 Alarm cancel method 5 7 Back light flickers during alarms 5 8 Moto...

Page 83: ...KOREA CO LTD 3F 1480 6 Gayang Dong Gangseo Gu Seoul 157 200 Korea 82 2 3660 9644 Malaysia MITTRIC SDN BHD No 5 Jalan Pemberita U1 49 Temasya Industrial Park Glenmarie 40150 Shah Alam Selangor Malaysi...

Reviews: