—19—
POWER SUPPLY
220-240V 50Hz
2
1
TB5 (M-NET)
(*1)
Optional Remote controller
A
B
S
(PZ-60DR-E)
*When the optional Remote Controller PZ-60DR-E
cable
(non-polar)
24VDC 2A 5VDC 100mA
MAX 240VAC 2A MIN 220VAC 100mA
L
L
N
N
M
1
M
2
PE
monitor output
Operation or Delay1
LS
TR
TM1
CN1
CN2
CN7
BLUE
BROWN
YELLOW
RED
BROWN
RED
BLUE
BLUE
EXHAUST
FAN MOTOR
SUPPLY
FAN MOTOR
WHITE
ORANGE
YELLOW
GREY
BLACK
C
C
SA2
SA1
SW2
SW5
SW1
CN6
ORANGE
ORANGE
TH1 (OA)
TH2 (RA)
ORANGE
ORANGE
ORANGE
ORANGE
TM2
BROWN
PZ-
60DR-E
Transmission
TB5
TM3
TAB3
TAB5
CN10
CN9
TAB1
TAB2
Isolator
X12 X11
CN32
X10
S
B
A
9
2
1
CN5
3
2
1
6
7
8
10
CN16
TM4
RED
BROWN
output 7 , 8
Malfunction monitor
monitor output 6 , 7
By-pass or Delay2
MAX 240VAC 1A
12V or 24V DC
Mr.Slim
(non-polar)
2nd remote controller
(Max. two remote controllers installable)
2nd LOSSNAY unit (Up to max 15 units)
MELANS cable
transmission
M-NET
Shield Wire
24VDC 1A
MAX 240VAC 1A
5VDC 100mA
MIN 220VAC 100mA
Unchanged a-contact
1
3
External control input
TM4
(Max. two remote controllers
2nd remote controller
Shield Wire
cable
transmission
M-NET
2nd or later main units
installable)
(*1)PZ-41SLB-E and PZ-52SF-E cannot
be used when using PZ-60DR-E.
is used as the M-NET System, connect it to
of TM4 terminal block, and connect M-NET
transmission wire to , on TB5 terminal
block.
1
2
A
B
GM
CN16
(Unchanged a-contact)
HI
LO
EXTRA-LO
BY-PASS
(*1)
With this product, the wiring installation method will
vary according to the design of the system.
Perform electrical installation to meet local electrical regulations.
.Always use double insulated PVC cable for the transmission cables.
.Wiring work must be performed by qualified professionals.
.All supply circuits must be disconnected before obtaining access to the terminal devices.
NOTE 1.TM1, TM2, TM3, TM4, TB5 shown
in dotted lines are field work.
2.Isolator should be provided by the customer.
3.Be sure to connect the grounding wire.
*Attention
BROWN
RED
ORANGE
YELLOW
GREEN
4. Electrical wiring diagrams
LGH-15RX
5
-E, LGH-25RX
5
-E, LGH-35RX
5
-E, LGH-50RX
5
-E, LGH-65RX
5
-E, LGH-80RX
5
-E, LGH-100RX
5
-E
Definition of Symbols
M1:
Motor for exhaust fan
CN1:
Connector (Transformer primary)
M2:
Motor for supply fan
CN2:
Connector (Transformer secondary)
C:
Capacitor
CN5:
Connector (Thermistor)
GM:
Motor for By-pass operation
CN6:
Connector (Microswitch)
LS:
Microswitch
CN7:
Connector (Motor for By-pass operation)
TH1:
Thermistor for outside air
TAB3:
Tab connector(Fan motor)
TH2:
Thermistor for return air
TAB5:
Tab connector (Fan motor)
SW1:
Switch (Main/Sub change)
CN9:
Connector (Fan motor)
SW2, 5:
Switch (Function selection)
CN10:
Connector (Fan motor)
TM1:
Terminal block (Power supply)
CN16:
Connector (High/Low/Extra Low/By-pass switch)
TM2:
Terminal block (External control input)
CN32:
Connector (Remote control selection)
TM3:
Terminal block (Monitor output)
SA1:
Address setting rotary switch (10 digit)
TM4 :
Terminal block (Transmission cable and monitor output)
SA2:
Address setting rotary switch (1 digit)
TB5 :
Terminal block (M-NET Transmission cable)
SYMBOL
: Indicates terminal block.
TAB1,TAB2:
Connector (Power supply)
: Connector.
TR:
Control circuit transformer
: Board insertion connector or fastening
X10,X11,X12:
Relay contact
connector of control board.
*Specifications may be subject to change without notice.
Summary of Contents for LGH-100RX5-E
Page 4: ...4 2 Specifications...
Page 5: ...5...
Page 6: ...6...
Page 7: ...7...
Page 8: ...8...
Page 9: ...Unit mm LGH 15RX5 E 3 Outside dimensions 9...
Page 10: ...Unit mm LGH 25RX5 E 10...
Page 11: ...Unit mm LGH 35RX5 E 11...
Page 12: ...12 Unit mm LGH 50RX5 E...
Page 13: ...Unit mm LGH 65RX5 E 13...
Page 14: ...14 Unit mm LGH 80RX5 E...
Page 15: ...Unit mm LGH 100RX5 E 15...
Page 16: ...16 Unit mm LGH 150RX5 E...
Page 17: ...Unit mm LGH 200RX5 E 17...