10 - 10 10 - 10
MELSEC-F
10 USING THE E-MAIL FUNCTION
POINT
If the inquiry time interval from the PLC or other module to the server is short
because of the POP3 server specifications, access may be restricted (lock status)
on the server side.
Check the POP3 server specifications, and set the inquiry time interval accordingly.
(It is recommended to set the value of the inquiry time interval to the default (5
minutes) or more.)
(b) Mail server name
Set the domain name or IP addresses of the mail servers designated by the
system administrator, used by the local station's Ethernet module.
1) Designate the domain name of the mail server.
2) Select the input format (decimal/hexadecimal) of the IP addresses.
3) Set the IP address of the outgoing mail server (SMTP).
4) Set the IP address of the incoming mail server (POP3).
POINT
• The SMTP server delivers (transfers) e-mails between mail servers.
• The POP3 server transfers received e-mails addressed to users to the
corresponding users.
• The mail server names must be designated in order to use the e-mail function.
(See POINT of (1).)
NOTE
To adjust the settings in FX Configurator-EN (GX Developer), select [Email Settings]
from the initial screen and adjust the settings from the email settings screen.