background image

This manual confers no industrial property rights or any rights of any other kind, 
nor does it confer any patent licenses. Mitsubishi Electric Corporation cannot be 
held responsible for any problems involving industrial property rights which may 
occur as a result of using the contents noted in this manual.

Warranty

Mitsubishi will not be held liable for damage caused by factors found not to be 
the cause of Mitsubishi; machine damage or lost profits caused by faults in the 
Mitsubishi products; damage, secondary damage, accident compensation 
caused by special factors unpredictable by Mitsubishi; damages to products 
other than Mitsubishi products; and to other duties.

For safe use

This product has been manufactured as a general-purpose part for general 
industries, and has not been designed or manufactured to be incorporated in 
a device or system used in purposes related to human life.
Before using the product for special purposes such as nuclear power, electric 
power, aerospace, medicine or passenger movement vehicles, consult with 
Mitsubishi Electric.
This product has been manufactured under strict quality control. However 
when installing the product where major accidents or losses could occur if the 
product fails, install appropriate backup or failsafe functions in the system.

HEAD OFFICE

HIMEJI WORKS

 : TOKYO BUILDING, 2-7-3 MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, 
   JAPAN
 : 840, CHIYODA CHO, HIMEJI, JAPAN

Side

B

Side

A

Side

B

JAPANESE

ENGLISH

JY997D16401B

Safety Precaution

 

(Read these precautions before use.)

This manual classify the safety precautions into two categories: 

 and 

.

Depending on circumstances, procedures indicated by 

 may also be

linked to serious results.
In any case, it is important to follow the directions for usage.

Associated Manuals

How to obtain manuals

For the necessary product manuals or documents, consult with the Mitsubishi
Electric dealer from where you purchase your product.

Applicable Standard

FX

3U

-2HSY-ADP complies with EC directive (EMC Directive) and UL standards

(UL, cUL). Further information can be found in the following manual.

→ 

→ 

→ 

→ 

Refer to FX

3U

 Series Hardware Manual (Manual No. JY997D18801)

Indicates that incorrect handling may cause hazardous
conditions, resulting in death or severe injury.

Indicates that incorrect handling may cause hazardous
conditions, resulting in medium or slight personal injury
or physical damage.

Manual name

Manual No.

Description

FX

3U

 Series 

User’s Manual 
- Hardware Edition

JY997D16501

MODEL CODE: 

09R516

Expl ain s FX

3 U

 Se r ies PL C

specification details for I/O,
w i r i n g ,   i n s t a l l a t i o n ,   a n d
maintenance.

FX

3U

/FX

3UC

 Series 

Programming Manual 
-   B a s i c   &   A p p l i e d
Instruction Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC programming
for basic/applied instructions
and devices.

FX

3U

/FX

3UC

 Series 

User’s Manual 
- Positioning Control
Edition

JY997D16801

MODEL CODE: 

09R620

Describes positioning control
and programming using FX

3U

/

FX

3UC

 Series PLC 

1. Outline

The FX

3U

-2HSY-ADP high-speed output special adapter (hereinafter called high-speed

output special adapter) is a special adapter dedicated to FX

3U

 Series PLC. It outputs

pulse signals of a differential line driver system for applicable Servo Amplifiers (or Drive
Unit) of an AC servomotor or stepper motor.
Up to two units of this special adapter can be connected to the main unit per system.

→ 

→ 

→ 

→ 

For system configuration, refer to the FX

3U

 Series

User's Manual - Hardware Edition.

1.1 Incorporated Items

Check if the following product and items are included in the package:

1.2 Output Number and Signal

When power is turned on, the output numbers and signals of the high-speed output
special adapters are allocated as shown in the table below in the order of it near the
main unit. 

*1 A function extension board is required to use the high-speed I/O special adapter

together with a communication/analog special adapter. 

→ 

→ 

→ 

→ 

For system configuration, refer to the FX

3U

 Series

User's Manual - Hardware Edition.

Caution

1) When a high-speed output adapter is connected, the same output number is

allocated to both the main unit and this adapter. Use either output terminal and do
not wire to the unused output terminal.
The outputs from the high-speed output special adapter and main unit are
operated as below: 

*1 The output frequency of transistor outputs in the main unit is a maximum of

100kHz. If the load is operated using pulses at a frequency more than 100kHz,
PLC may be damaged.

*2 PWM instruction has not supported the relay output for the reasons of the

response delay of the output, chattering of contact, the contact life, etc.

Products

Manual

Status of 

output form 

setting 

switch

Signal name

Output number

First unit

Second unit

1st axis

2nd axis

1st axis

2nd axis

FP

RP side

Forward pulse train (FP)

Y000

Y001

Y002

Y003

Reverse pulse train (RP)

Y004

Y005

Y006

Y007

SG

SG1

SG2

SG3

SG4

PLS

DIR side

Pulse train

Y000

Y001

Y002

Y003

Direction

Y004

Y005

Y006

Y007

SG

SG1

SG2

SG3

SG4

instructions

Output operation

High-speed 

output special 

adapter

Main unit

Transistor-

output type

Relay-output type

PLSY,PLSR,DSZR,
DVIT,TBL,ZRN,
PLSV,DRVI,DRVA

Operated

Operated

*1

While instruction is activated,
relevant output is ON. (LED is
also ON.)

PWM

Operated

Operated

Do not apply PWM instruction
fo r   re l ay- o u t p u t   t y p e   m a i n

unit.

*2

Other

Operated

Operated

Operated

SGB

Y5/7 -+

Y1/3 -+

Y4/6 -+

Y0/2 -+

Y4/6 Y5/7

Y1/3

Y0/2

POWER

FX   -2HSY-ADP

3U

FP  RP

PLS  DIR

SGA

This

manual

First unit

Second unit

High-

speed

input

special

adapter

Analog
special

function
adapter

Main unit

Expansion board

*1

High-

speed

output

special

adapter

High-

speed

output

special

adapter

High-

speed

input

special

adapter

Analog
special

function
adapter

Analog
special

function
adapter

2) During STOP or PLC power off modes, set the output form operation.

Do not set the output form operation during pulse train output.

1.3 External Dimensions, Part Names, and Terminal Layout 

[1]

DIN rail mounting groove (DIN rail: DIN46277)

[2]

High-speed I/O special adapter connector cover:
Remove this cover for connecting high-speed I/O special adapter on the left side.

[3]

Name plate

[4]

Special adapter slide lock: 
Used to connect special adapter on left side of this special adapter.

[5]

Special adapter connector cover:
Remove this cover for connecting special adapter on the left side.

[6]

Output terminal block (European type):
Connected to Servo Amplifier (or Drive Unit) to which pulse signal of differential
line driver system can be input.

[7]

Output form setting switch
Either "Forward pulse train (FP)/Reverse pulse train (RP)" or "pulse train +
direction" is selected. For setting, refer to the following manual.

→ 

Refer to FX

3U

 / FX

3UC

 Series User's Manual - Positioning Control Edition.

[8]

Output LED (red):
Lit when output turns ON (if output turns ON and OFF alternately at high speed,
LED flickers fast).

[9]

POWER LED (green):
Lit while power is properly supplied from main unit.

[10] Direct mounting hole:2 holes of 

φ

4.5 (0.18") (mounting screw: M4 screw)

[11] Special adapter fixing hook

[12] DIN rail mounting hook

[13] Special adapter connector:

Used to connect communication special adapter or analog special adapter to this
adapter on left side.

[14] High-speed I/O special adapter connector:

Used to connect high-speed I/O special adapter to this adapter on left side.

17.6 (0.70")

90 (3.55")

98 (3.86")

15.1 (0.60")

106 (4.18")

74 (2.92")

15.5 (0.62")

7 (0.28")

SGB

Y5/7 -+

Y1/3 -+

Y4/6 -+

Y0/2 -+

Y4/6 Y5/7

Y1/3

Y0/2

POWER

FX   -2HSY-ADP

3U

FP  RP

PLS  DIR

SGA

Name

Output number

First

unit

Second

unit

Name

Output number

First

unit

Second

unit

[13]

Output LED [8]

Y0/2

Y1/3

Y4/6

Y5/7

Y000

Y001

Y004

Y005

Y002

Y003

Y006

Y007

Terminal layout of [6] 

Y0/2+

Y0/2-

Y4/6+

Y4/6-

SGA

Y1/3+

Y1/3-

Y5/7+

Y5/7-

SGB

Y000+

Y000-

Y004+

Y004-

Y001+

Y001-

Y005+

Y005-

Y002+

Y002-

Y006+

Y006-

Y003+

Y003-

Y007+

Y007-

[14]

[1]

[2]

[3]

[4]

[5]

[6]

[10]

[9]
[8]

[11]

[10]

[12]

Unit     : mm (inches)
Weight: 80 g (0.18 lbs)

[7]

[7] Output mode setting switch

Name

Setting

Upper

Lower

FP RP side

PLS DIR

Fwd pulse train (FP)
Rev pulse train (RP)

Pulse train + direction

Special adapter 
connector cover [2] 
or [5] is removed 

SGA

SGB

SGA

SGB

2-

φ

4.5

Mounting holes

2. Installation

The product can be mounted on DIN rail (DIN46277) or mounted directly using
screws.
For installation/uninstallation and safety precautions, refer to the following manual,
too:

→ 

→ 

→ 

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition.

  

2.1 Connection to the FX

3U

 Series PLC

Refer to the procedure 2) for configuring a new system.

Refer to the procedure 1) for adding product to an existing system.

Procedure

1) Turn off the power.

Disconnect all the cables connected to the PLC main unit and special adapter. 
Dismount the main unit and special adapter mounted on DIN rail or mounted
directly using screws. 

2) Install an expansion board to the main unit.

For installation of expansion board, refer to the following manual:

→ 

→ 

→ 

→ 

Refer to the FX

3U

 Series User's Manual - Hardware Edition

3) Remove the high-speed I/O special adapter

connector cover (Right fig. A) and the special
adapter connector cover (Right fig. B) on the
main unit.
In case of connecting this product to a high-
speed I/O special adapter as an addition,
please replace the 'main unit' in the above
description with a 'special adapter' and
perform the procedure as indicated. (Please
replace the following procedures similarly.)

4) Slide the special adapter slide lock (Right

fig.C) of the main unit.

5) Connect the high-

speed I/O special 
adapter (Right 
fig.D) to the main 
unit as shown on 
the right.

6) Slide back the 

special adapter 
slide lock (Right 
fig.C) of the main 
unit to fix the high-
speed I/O special 
adapter (Right 
fig.C). 

Connection precautions

Install the expansion board to be used before connecting a special adapter. 

Install an expansion board when using a special adapter other than a high-
speed I/O special adapter in combination with a high-speed I/O special
adapter.

Connect all the high-speed I/O special adapters before connecting other
special adapters when they are used in combination.

Do not connect a high-speed I/O special adapter on the left side of a
communication or analog special adapter.

INSTALLATION 
PRECAUTIONS

Cut off all phases of the power source externally before starting the
installation or wiring work, thus avoiding electric shock or damages to the
product.

INSTALLATION 
PRECAUTIONS

Use the product in the environment within the general specifications
described in PLC main unit manual (Hardware Edition).
Never use the product in areas with dust, oily smoke, conductive dusts,
corrosive gas (salt air, Cl

2

, H

2

S, NH

3

, SO

2

, or NO

2

), flammable gas,

vibrations or impacts, or expose it to high temperature, condensation, or wind
and rain.
If the product is used in such a place described above, electrical shock, fire,
malfunction, damage, or deterioration may be caused.

When drilling screw holes or wiring, cutting chips or wire chips should not
enter ventilation slits.
Such an accident may cause fire, failure or malfunction.

Do not touch the conductive parts of the product directly, thus avoiding failure
or malfunction.

Fix the special adapter securely to the specified connector. 
Incorrect connection may cause malfunction.

RU

N

ST

OP

FX

FX

3U

3U

-48

MR

/ES

-48MR/ES

FX

FX

3U

3U

-48M

-48M

IN

10

1

FX

3U

-48

M

3)

4)

C

C

B

4)

4)

4)

A

RU

N

ST

OP

FX

FX

3U

3U

-48M

R/E

S

-48MR/ES

FX

FX

3U

3U

-48M

-48M

PO

WE

R

Y0/2

Y4/6

Y1/3

Y5/7

FP .

RP

FX

3U

-2H

SY-A

DP

FX

3U

-48

M

6)

D

C

C

5)

5)

5)

6)

6)

6)

3. Used cables and Tightening Torque on Terminal 

For connection example and wiring, refer to the following manual.

→ 

→ 

→ 

→ 

Refer to FX

3U

 Series User's Manual - Hardware Edition.

  

1) Wire size

To connect to the desired unit, use a shielded twisted pair cable having a
conductor(s) of size AWG22-20.

2) Applicable cable

3) Termination of cable end

Strip the coating of strand wire and twist the cable core before connecting it,
or strip the coating of single wire before connecting it.
An alternative connection is to use a ferrule with insulating sleeve. 

When using a stick terminal with insulating sleeve, choose a wire with proper
cable sheath referring to the above outside dimensions, or otherwise, the wire
cannot be inserted easily.
The tightening torque must be 0.22 to 0.25N

m.

WIRING 
PRECAUTIONS

Cut off all phases of power source externally, before installation or wiring
work in order to avoid electric shock or damage of product.

WIRING 
PRECAUTIONS

Never let cutting chips and wire chips enter the ventilation slits of this product
or PLC when performing wiring.
Otherwise, fire, failure or malfunction may occur.

Make sure to observe the precautions below in order to prevent any damage
to a machine or any accident which might be caused by abnormal data
written in the PLC due to the influence of noise:

1)Do not lay close or bundle with the main circuit, high-voltage power line, or

load line. 
Otherwise effects of noise or surge induction are likely to take place.
Keep a safe distance of more than 100 mm (3.94") from the above when
wiring.

2)Ground the shield wire or shield of a shielded cable at one point on the

PLC. However, do not ground at the same point as high voltage lines.

Observe the following items to wire the lines to the European terminal board.
Failing to do so may cause electric shock, short circuit, disconnection, or
damage of the product.

- The disposal size of the cable end should follow the dimensions described 

in this manual.

- Tighten to a torque should follow the torque described in this manual.

- Twist the end of strands and make sure there is no loose wires. 

- Do not solder-plate the electric wire ends.

- Connect only the electric wires of regulation size.

- Fix the electric wires so that the terminal block and connected parts of 

electric wires are not directly stressed.

Type

Wire size

Single-wire

0.3mm

2

 to 0.5mm

2

 (AWG22 to 20)

2-wire

2 pieces of 0.3mm

2

 (AWG22)

Manufacturer

Model

Caulking tool

Phoenix Contact Co., Ltd.

AI 0.5-8WH

CRIMPFOX UD6

9mm

(0.35")

- Strand wire/single wire

8mm

(0.31")

Contact area

14mm(0.55")

2.6mm(0.1")

Insulation sleeve

- Stick terminal with insulating sleeve

4. Specification 

 

4.1 Applicable PLC

The version number can be checked by monitoring D8001 as the last three digits
indicate it.

Note

Cannot be connected to FX

3UC

-32MT-LT.

4.2 General Specifications

For general specifications, refer to the manual of the PLC main unit.
The items other than the following are equivalent to those of the PLC main unit.

→ 

→ 

→ 

→ 

Refer to FX

3U

 Series User's Manual - Hardware Edition.

4.3 Power Supply Specification

4.4 Performance Specification

STARTUP AND 
MAINTENANCE 
PRECAUTIONS

Do not disassemble or modify the unit.
Doing so may cause failure, malfunction or fire.
* For repair, contact your local Mitsubishi Electric distributor.

Do not drop the product or do not exert strong impact, doing so may cause
damage.

DISPOSAL 
PRECAUTIONS

Please contact a company certified in the disposal of electronic waste for
environmentally safe recycling and disposal of your device.

TRANSPORT AND 
STORAGE PRECAUTIONS

During transportation avoid any impact as the product is a precision instrument.
Check the operation of the product after transportation.

Model name

Applicability

FX

3U

 Series PLC

Ver. 2.20 (from the first product) and later

Item

Specification

Dielectric 
withstand voltage

500V AC for one minute Conforming to JEM-1021

Be twe en out pu t t er min al of high -
speed output special adapter and
ground terminal of PLC main unit

Insulation 
resistance

5M

 or more by 500V

DC megger

Item

Specification

Output circuit 
driving power supply 

60mA for 24V DC
Internally supplied from the main unit service power supply.

Adapter driving 
power supply

30mA for 5V DC
5V DC power is supplied internally from the main unit.

Item

Specification

Number of 
controlled axis

Independent two axes

Output points

4 points (Not counted among the total I/O points of the PLC.)

Output system

Differential line driver (Equivalent to AM26C31)

Output form

Forward pulse train, reverse pulse train, or pulse train +
direction

Load current

25 mA or less

Maximum output 
frequency

200 kHz

Insulation

External cables of output area are insulated from PLC by
photo coupler or transformer.

SG are insulated from each other by transformer.

Wiring length

Maximum 10m (32' 9")

4.5 Output Interface Internal Circuit

For connection example and wiring, refer to the following manual.

→ 

→ 

→ 

→ 

Refer to FX

3U

/FX

3UC

 Series User's Manual - Positioning Control Edition

Grounding

Ground properly with reference to the Servo Amplifier (or Drive Unit) manual. If
not indicated, ground as below.

- Grounding (when not indicated)

- The grounding resistance should be 100

 or less.

- Independent grounding should be performed for best results.

When independent grounding is not performed, perform "shared 
grounding" of the following figure.

→ 

→ 

→ 

→ 

For details, refer to the FX

3U

 Series User's

Manual - Hardware Edition.

- The grounding wire size should be AWG 14 (2 mm

2

) or larger.

- The grounding point should be close to the PLC, and all grounding wire

should be as short as possible.

High-speed output special

adapter

Servo Amplifier

(or Drive Unit)

SGA

*1  Y00    indicates output number of the high-speed output special adapter.
*2  'SGA' is insulated from 'SGB'.
*3  Ground properly with reference to the Servo Amplifier (or Drive Unit) manual. If not
      indicated, ground as below.

Y00   +

Y00   -

*1

*1

*2

*3

SGB

Y00   +

Y00   -

*1

*1

*2

Servo Amplifier

(or Drive Unit)

*3

Grounding

(Ground resistance:

 100

 or less)

Grounding

(Ground resistance:

 100

 or less)

SGA

SGB

5V

5V

Equivalent

to

AM26C31

Equivalent

to

AM26C31

PLC

Another

equipment

PLC

Another

equipment

PLC

Another

equipment

Shared grounding

Good condition

Common grounding

Not allowed

Independent grounding

Best condition

FX

3U

-2HSY-ADP

INSTALLATION MANUAL

This manual describes the part names, dimensions, mounting, and
specifications of the product. Before use, read this manual and manuals of
relevant products fully to acquire proficiency in handling and operating the
product. Make sure to learn all the product information, safety information, and
precautions.
And, store this manual in a safe place so that you can take it out and read it
whenever necessary. Always forward it to the end user.
Registration
The company name and the product name to be described in this manual are
the registered trademarks or trademarks of each company.

Effective Dec. 2005
Specifications are subject to change without notice.

 2005 Mitsubishi Electric Corporation

Manual Number

JY997D16401

Revision

B

Date

December 2005

Reviews: