- 15 -
converter output voltage
regenerative brake duty
electronic overcurrent protection load factor
output current peak value
input power
output power
frequency setting
peak voltage
terminal in
terminal out
4.5.3. Parameter Read
For parameter reading, all standard and special parameters are supported.
In addition, the parameters listed in the Option-specific Parameter section
of this specification are supported. Hidden parameters are not supported.
All available parameters are available all the time, regardless of special
settings which may be needed to read parameters using the PU or other
communications option cards (e.g. Prs. 61-64 and 201-230).
4.6.
Operation on Alarm Occurrence
The following table shows the behavior of inverter and network
communication operation on alarm occurrence.
operation mode
type of fault
item
net mode
external
mode
PU mode
inverter
inverter operation
stop
stop
stop
network
communication
continue
continue
continue
DeviceNet
inverter operation
stop *1
continue
continue
communicati
on
network
communication
continue *2
continue *2
continue
*2
*1: inverter operation stops if EPN signals option error to drive on expiration
of Inactivity/Watchdog timer of Connection Object.
*2: depends on the type of communication fault