background image

9

7.  Press the appropriate Temperature set button 

3

 to set the desired 

temperature (at 

7

).

*  Each press changes the setting, in the following sequence: No 

display (no setting) 

 24 

 25 

 ... 

 29 

 30 

 12 

 ... 

 

23 

 No display.

  (Available range: The range for the setting is 12 °C to 30 °C. 

The actual range over which the temperature can be controlled, 
however, will vary according to the type of the connected unit.)

8.  After making the appropriate settings at Steps 5, 6 and 7, press the 

Filter   button 

4

 to lock in the values.

 

To clear the currently set values for the selected operation, press 
and quickly release the Check (Clear) button 

0

 once. 

*  The displayed time setting will change to “—:—”, and the On/Off 

and temperature settings will all disappear.

  (To clear all weekly timer settings at once, hold down the Check 

(Clear) button 

0

 for two seconds or more. The display will begin 

flashing, indicating that all settings have been cleared.)

 Note:
 

Your new entries will be cancelled if you press the Operation mode 
(Back) button 

2

 before pressing the Filter 

 button 

4

.

 

If you have set two or more different operations for exactly the same 
time, only the operation with the highest Operation No. will be carried 
out.

9.  Repeat Steps 3 to 8 as necessary to fill as many of the available 

cells as you wish.

10. Press the Operation mode (Back) button 

2

 to return to the 

standard control screen and complete the setting procedure.

11. To activate the timer, press the Timer On/Off button 

9

, so that the 

“Timer Off” indication disappears from the screen. 

Be sure that 

the “Timer Off” indication is no longer displayed.

*  If there are no timer settings, the “Timer Off” indication will flash 

on the screen.

<How to View the Weekly Timer Settings>

1.  Be sure that the weekly timer indicator is visible on the screen (at 

1

).

2.  Press the Timer Menu button 

b

 so that “Monitor” is indicated on 

the screen (at 

8

).

3.  Press the Timer On/Off (Set Day) button 

9

 as necessary to select 

the day you wish to view.

4. Press the   or 

 operation button (

7

 or 

8

) as necessary to 

change the timer operation shown on the display (at 

9

).

*  Each press will advance to the next timer operation, in order of 

time setting.

5.  To close the monitor and return to the standard control screen, 

press the Operation mode (Back) button 

2

.

<To Turn Off the Weekly Timer>

Press the Timer On/Off button 

9

 so that “Timer Off” appears at 

0

.

<To Turn On the Weekly Timer>

Press the Timer On/Off button 

9

 so that the “Timer Off” indication (at 

0

goes dark.

6.1.2. Simple Timer

 You can set the simple timer in any of three ways.

•  Start time only:
  The air conditioner starts when the set time has elapsed.
•  Stop time only:
  The air conditioner stops when the set time has elapsed.
•  Start & stop times:
  The air conditioner starts and stops at the respective elapsed times.

 The simple timer (start and stop) can be set only once within a 72-

hour period. 

  The time setting is made in hour increments.

Note:
*1.  Weekly Timer/Simple Timer/Auto Off Timer cannot be used at the same 

time. 

*2.  The simple timer will not operate when any of the following conditions is 

in effect. 

 

The timer is off; the system is in malfunction state; a test run is in 
progress; the remote controller is undergoing self-check or remote 
controller check; the user is in the process of selecting a function; the 
user is in the process of setting the timer; the system is under central 
control. (Under these conditions, On/Off operation is prohibited.)

<How to Set the Simple Timer>

1. Be sure that you are at a standard control screen, and that the simple 

timer indicator is visible in the display (at 

1

).

  When something other than the Simple Timer is displayed, set it to 

SIMPLE TIMER using the function selection of remote controller (see 
8.[4]–3 (3)) timer function setting. 

2. Press the Timer Menu button 

b

, so that the “Set Up” appears on the 

screen (at 

2

). (Note that each press of the button toggles the display 

between “Set Up” and “Monitor”.)

3. Press the ON/OFF button 

1

 to display the current ON or OFF simple 

timer setting. Press the button once to display the time remaining to 
ON, and then again to display the time remaining to OFF. (The ON/
OFF indication appears at 

3

).

• “ON” timer:
  The air conditioner will start operation when the specified number of 

hours has elapsed.

• “OFF” timer:
  The air conditioner will stop operation when the specified number of 

hours has elapsed.

4. With “ON” or “OFF” showing at 

3

: Press the appropriate Set Time 

button 

a

 as necessary to set the hours to ON (if “ON” is displayed) or 

the hours to OFF (if “OFF” is displayed) at 

4

.

•  Available Range: 1 to 72 hours

5. To set both the ON and OFF times, repeat Steps 3 and 4. 

*  Note that ON and OFF times cannot be set to the same value.

6. To clear the current ON or OFF setting: Display the ON or OFF setting 

(see step 3) and then press the Check (Clear) button 

0

 so that the 

time setting clears to “—” at 

4

. (If you want to use only an ON setting 

or only an OFF setting, be sure that the setting you do not wish to use 
is shown as “—”.)

ON

Hr

AFTER

SIMPLE

PAR-21MAA

ON/OFF 

FILTER

CHECK

OPERATION

CLEAR

TEST

TEMP.

MENU

BACK

DAY

MONITOR/SET

CLOCK

ON/OFF

2

a 9

0

4

1

b

ON

Hr

AFTER

SIMPLE

4

1

3

2

Timer Setting

Action (On or Off)

* “— —” is displayed if there is no 

setting.

°C

°C

TIME SUN

WEEKLY

0

6. Timer

°C

TIMER

SUN

ON

OFF

WEEKLY

1

9

8

°C

°C

TIME SUN

WEEKLY

0

Timer Settings

Summary of Contents for City Multi PKFY-P VKM-E

Page 1: ...r gebruikt ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unit per un uso corretto e sicuro della stessa MANUAL DE INSTRUCCIONES Lea este manual...

Page 2: ...out or leaks stop the operation of the air conditioner thoroughly ventilate the room and contact your dealer Warning The unit must not be installed by the user Ask the dealer or an authorized company...

Page 3: ...have been locked Clean the filter indicator Comes on when it is time to clean the filter Timer indicators The indicator comes on if the corresponding timer is set For purposes of this explanation all...

Page 4: ...ubject it to strong shocks In addition do not get the remote controller wet or leave it in a location with high humidity To avoid misplacing the remote controller install the holder included with the...

Page 5: ...s advances the day shown at 3 Sun Mon Fri Sat 3 Press the appropriate Set Time button a as necessary to set the time As you hold the button down the time at 4 will increment first in minute intervals...

Page 6: ...de Fan mode Heat mode Automatic cool heat operation mode Automatic operation According to a set temperature cooling operation starts if the room temperature is too hot and heating operation starts if...

Page 7: ...temperature setting Manual To Change the Airflow s Left Right Direction The louver button 7 cannot be used Model PKFY P VKM E Stop the unit operation hold the lever of the louver and adjust to the des...

Page 8: ...mer Menu button b so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the Timer On Off Set Day button 9 to set the d...

Page 9: ...e only The air conditioner starts when the set time has elapsed Stop time only The air conditioner stops when the set time has elapsed Start stop times The air conditioner starts and stops at the resp...

Page 10: ...button 4 8 Press the Operation mode Back button 2 to return to the standard control screen 9 Press the Timer On Off button 9 to start the timer countdown When the timer is running the timer value is v...

Page 11: ...mode to stop the unit will cancel the timers If the current time has not been set the timer operation cannot be used 7 Other Functions C C TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CL...

Page 12: ...remote controllers are connected to one group one controller must be set to sub 2 Use of clock setting CLOCK Setting the use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting...

Page 13: ...ction setting is not used Initial setting value Operation lock setting is except On Off button Operation lock setting is All buttons The automatic mode is displayed when the operation mode is selected...

Page 14: ...it setting press the button H The selected setting will flash and the temperature can be set Settable range Cool Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heat mode Lower limit 17 C 28 C Up...

Page 15: ...se French Japanese CHANGE LANGUAGE Function selection Operation function limit setting Use of automatic mode setting Temperature range limit setting Limit temperature cool day mode Limit temperature h...

Page 16: ...ating the unit without air filters can cause malfunction 10 Care and Cleaning Caution Before you start cleaning stop operation and turn OFF the power supply Indoor units are equipped with filters to r...

Page 17: ...ter forward to remove the filter A Knob B Grille C Intake grille D Filter B A D C Cleaning the indoor unit Wipe the outside of the unit with a clean dry soft cloth Clean off any oil stains or finger m...

Page 18: ...r unit During cool mode water may form and drip from the cool pipes and joints During heat mode water may form and drip from the heat exchanger During defrosting mode water on the heat exchanger evapo...

Page 19: ...es Y R2 Multi S is as below Caution The use of your air conditioner outside the range of working temperature and humidity can result in serious failure Mode Indoor unit Outdoor unit PUHY PURY PUMY Coo...

Page 20: ...be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand BG79U3...