 Wireless Remote-Controller

2. Parts Names

Transmission indicator

Timer indicator

 When using the wireless remote controller, point it towards the receiver on the indoor unit.
 If the remote controller is operated within approximately two minutes after power is 

supplied to the indoor unit, the indoor unit may beep twice as the unit is performing the 
initial automatic check.

 The indoor unit beeps to confirm that the signal transmitted from the remote controller has 

been received. Signals can be received up to approximately 7 meters in a direct line from 
the indoor unit in an area 45° to the left and right of the unit. However, illumination such 
as fluorescent lights and strong light can affect the ability of the indoor unit to receive 
signals.

 If the operation lamp near the receiver on the indoor unit is flashing, the unit needs to be 

inspected. Consult your dealer for service.

 Handle the remote controller carefully! Do not drop the remote controller or subject it to 

strong shocks. In addition, do not get the remote controller wet or leave it in a location 
with high humidity.

 To avoid misplacing the remote controller, install the holder included with the remote 

controller on a wall and be sure to always place the remote controller in the holder after 
use.

*  For explanation purposes, all of the items 

that appear in the display are shown.

*  All items are displayed when the Reset 

button is pressed.

Remote controller display

ON/OFF button

Temperature set buttons

Fan Speed button (Changes fan speed)

Airflow button (Changes airflow up/down direction)

Mode button (Changes operation mode)

Check button

Test Run button

Transmission area

Operation areas

Timer Off button 

Timer On button 

Hour button

Minute button

Set Time button (Sets the time)

Louver button (Changes left/right direction)

Reset button

Battery installation/replacement

1. Remove the top cover, insert two AAA 

batteries, and then install the top cover.

2. Press the Reset button.

1

2

3

Top cover

Two AAA batteries
Insert the negative 
(–) end of each 
battery first. Install the 
batteries in the correct 
directions (+, –)!

Press the Reset button 
with an object that has 
a narrow end.

Summary of Contents for City Multi PKFY-P VKM-E

Page 1: ...r gebruikt ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l unit per un uso corretto e sicuro della stessa MANUAL DE INSTRUCCIONES Lea este manual...

Page 2: ...out or leaks stop the operation of the air conditioner thoroughly ventilate the room and contact your dealer Warning The unit must not be installed by the user Ask the dealer or an authorized company...

Page 3: ...have been locked Clean the filter indicator Comes on when it is time to clean the filter Timer indicators The indicator comes on if the corresponding timer is set For purposes of this explanation all...

Page 4: ...ubject it to strong shocks In addition do not get the remote controller wet or leave it in a location with high humidity To avoid misplacing the remote controller install the holder included with the...

Page 5: ...s advances the day shown at 3 Sun Mon Fri Sat 3 Press the appropriate Set Time button a as necessary to set the time As you hold the button down the time at 4 will increment first in minute intervals...

Page 6: ...de Fan mode Heat mode Automatic cool heat operation mode Automatic operation According to a set temperature cooling operation starts if the room temperature is too hot and heating operation starts if...

Page 7: ...temperature setting Manual To Change the Airflow s Left Right Direction The louver button 7 cannot be used Model PKFY P VKM E Stop the unit operation hold the lever of the louver and adjust to the des...

Page 8: ...mer Menu button b so that the Set Up appears on the screen at 2 Note that each press of the button toggles the display between Set Up and Monitor 3 Press the Timer On Off Set Day button 9 to set the d...

Page 9: ...e only The air conditioner starts when the set time has elapsed Stop time only The air conditioner stops when the set time has elapsed Start stop times The air conditioner starts and stops at the resp...

Page 10: ...button 4 8 Press the Operation mode Back button 2 to return to the standard control screen 9 Press the Timer On Off button 9 to start the timer countdown When the timer is running the timer value is v...

Page 11: ...mode to stop the unit will cancel the timers If the current time has not been set the timer operation cannot be used 7 Other Functions C C TIME SUN FUNCTION PAR 21MAA ON OFF FILTER CHECK OPERATION CL...

Page 12: ...remote controllers are connected to one group one controller must be set to sub 2 Use of clock setting CLOCK Setting the use or non use of clock function 3 Timer function setting WEEKLY TIMER Setting...

Page 13: ...ction setting is not used Initial setting value Operation lock setting is except On Off button Operation lock setting is All buttons The automatic mode is displayed when the operation mode is selected...

Page 14: ...it setting press the button H The selected setting will flash and the temperature can be set Settable range Cool Dry mode Lower limit 19 C 30 C Upper limit 30 C 19 C Heat mode Lower limit 17 C 28 C Up...

Page 15: ...se French Japanese CHANGE LANGUAGE Function selection Operation function limit setting Use of automatic mode setting Temperature range limit setting Limit temperature cool day mode Limit temperature h...

Page 16: ...ating the unit without air filters can cause malfunction 10 Care and Cleaning Caution Before you start cleaning stop operation and turn OFF the power supply Indoor units are equipped with filters to r...

Page 17: ...ter forward to remove the filter A Knob B Grille C Intake grille D Filter B A D C Cleaning the indoor unit Wipe the outside of the unit with a clean dry soft cloth Clean off any oil stains or finger m...

Page 18: ...r unit During cool mode water may form and drip from the cool pipes and joints During heat mode water may form and drip from the heat exchanger During defrosting mode water on the heat exchanger evapo...

Page 19: ...es Y R2 Multi S is as below Caution The use of your air conditioner outside the range of working temperature and humidity can result in serious failure Mode Indoor unit Outdoor unit PUHY PURY PUMY Coo...

Page 20: ...be sure to put the contact address telephone number on this manual before handing it to the customer HEAD OFFICE TOKYO BLDG 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN Printed in Thailand BG79U3...