FUEL SYSTEM <4D5-Step
III
> - On-vehicle Service
13-64
Standard value:
Jumper lead
Nipple A
Normal condition
Connected
Open
Negative pressure
leaks
Closed
Negative pressure
maintained
Disconnected
Open
Negative pressure
maintained
COIL RESISTANCE CHECK
1. Measure the resistance between the solenoid valve
terminals.
Standard value: 29 - 35
Ω
(at 20
_
C)
THROTTLE ACTUATOR CHECK
1. Remove the vacuum hose (yellow stripe) from the throttle
actuator and connect a hand vacuum pump to the throttle
actuator nipple.
2. Check that the actuator rod moves smoothly when
applying vacuum gradually.
Also, check that the vacuum is maintained when applying
53 kPa of vacuum.
VARIABLE GEOMETRY SOLENOID VALVE
CHECK
Refer to GROUP 15 - On-vehicle Service.
EGR CONTROL SOLENOID VALVE CHECK
Refer to GROUP 17 - Emission Control System <4D5-step
III
>.
Throttle actuator