53
-
'19 • KX-T-310D
L
6
4
3
2
1
F1
CNM1
WH
M
F2
CNM2
FM
i
2
RD
RD
1
2
CNI
FS
CNZ
For HA
WH
1
2
CNTA
RD
RD
YE
YE
1
2
3
4
5
6
1
2
XR1
XR2
XR3
XR4
1
2
3
4
5
6
X Y
1
3
X Y
WH
WH
8 9 10 11 12
8 9 10 11 12
CNW2
WH
CNW1
WH
WH
CNN
YE
CNH
CNT
L N
WH
RD
T1
T2
Power circuit
Th
C
Th
i
-R1
Th
i
-R2
Th
i
-R3
Th
i
-A
WH WH WH WH
Remote control
WH
WH WH WH
WH WH WH
3 4 5 6 7
1 2
5 6 7
2 3 4
1
CND
YE
WH
RD
1
4
5
6
7
YE
RD
WH
M
1
3
5
WH
RD
CNFM
WH
FM
i
1
6
4
3
2
1
CNM
WH
CNFM2
WH
WH
RD
Prepare on site
T4
T3
SW2
SW6
SW5
SW7
SW1
SW3
SW4
CNK2
JSL1
2
CNK1
WH
1
1
2
3
4
5
CNT2
RD
1
2
3
4
5
6
CNA
RD
SM
WH
YE
OR
RD
M
A
RD
between indoor units
Earth
Power source line
YE
YE
Color
RD
Red
WH
White
YE
Yellow
FS
Float switch
Indication lamp
Connector
SW6 SW7-
1
SW5-1
Thc
Thi-R
1,2,3
Thi-A
SW2
L
Reactor
Fuse
FMi1,2
CNA-Z
F1-3
Fan motor
JSL1
SW5-2
SW4
SW3
SW1
SM
Description
Item
OR
RD
CNU
WH
RD
3-pipe systems
between indoor units
Power source line
Drain motor
DM
CNR
WH
DM
M
1
2
RD
WH
Option
PIS
Motion sensor
1
1
PIS
CNG
2 3
2 3 4
1 2 3 4
WH
RD
WH RD
Option
CNV2
Prepare on site
Closed-end connector
Power source 1 Phase
Meaning of marks
Color marks
Temperature sensor(Remote control) Temperature sensor(Return air) Temperature sensor(Heat exchanger)
Notes
1.
---
--
indicates wiring on site.
2. Use twin core shielded cord(0.75 - 1.25mm
2
) at signal line between indoor unit
and outdoor unit, and signal line between indoor units.
3. Use twin core cord(0.3mm
2
) at remote control line.
See spec sheet of remote control in case that the total length is more than 100m. 4. Do not put signal line and remote control line alongside power source line.
5. Circuit option in (※1) is not include
d as standard from factory.
This circuit is an option when using drain up kit.
6. Section 1(※2)shows electric circuit of motion sensor(option)
.
FS
FMi1,2
SW2
Connector
CNA-Z
Drain motor
DM
TB1
SW6
Operation check, Drain motor test run
SW7-1
Fuse
F1,3,4
Thi-R1,2,3
Thi-A
Thc
LED・3
LED・2
TB2
Float switch
Indication lamp(Green-Normal operation)
Indication lamp(Red-Inspection)
Indoor unit address:ones place
Model capacity setting
Terminal block(Power source)(□mark)
Terminal block(Signal line)(□mark)
Temperature sensor(Remote control)
Temperature sensor(Return air)
Temperature sensor(Heat exchanger)
previous version of Superlink protocol
Fan motor
Power PCB
WH
8 9 10 11 12
8 9 10 11 12
CNW2
WH
CNW1
WH
L N
WH
RD
YE/GN
3
5
CNW0
WH
1
TB1
Power circuit
WH WH WH WH
WH
WH WH WH
WH WH WH WH
3 4 5 6 7
1 2
5 6 7
2 3 4
1
M
1
4
5
6
7
RD
F3
(2A)
CNM1
WH
FM
i
1
F1(6.3A)
YE/GN
Color
Mark
BK
Color marks
Meaning of marks
Black
BL
Blue
OR
Orange
RD
Red
Color
Mark
WH
White
YE
Yellow
YE/GN
Yellow/Green
JSL1
Spare Superlink connector change
BK
WH
BL
SM
Stepping motor
(For electronic expansion valve)
SW1
Indoor unit address:tens place
SW4
Outdoor unit address:ones place
SW3
Outdoor unit address:tens place
SW5-1
Automatic adjustment/Fixed
SW5-2
Indoor unit address:hundreds place
RD
WH
control of heat recovery
Connector for branching
3-pipe systems
CNU
BL
Power source
between indoor units
Power source line
Earth
line
RD
RD
1
2
CNI
BL
FS
CNZ
CNC
For HA
WH
RD
RD
t°
Control PCB
RD
YE
t°
YE
BK
t°
BK
1
2
3
4
5
6
BK
t°
BK
1
2
XR1
XR2
XR3
XR4
XR5(Remote operation
1
2
3
4
5
6
+12
SW2
SW6
SW5
SW7
LED・2
LED・3
X Y
1
3
X Y
t°
TB2
WH
BK
CNB
WH
CNN
YE
CNH
BK
CNT
BL
M
1
4
5
6
7
RD
F4
(2A)
CNM2
BK
(Operation) (Heating) (Thermo ON) (Inspection)
Th
C
Thi
-R1
Thi
-R2
Thi -R3
Thi
-A
Remote control
FM
i
2
input:volt-free contact)
1
2
3
4
5
6
CNA
RD
SM
WH
YE
OR
BL
RD
M
SW1
SW3
SW4
CNK2
Superlink(spare)
JSL1
BK
A B
1
2
(Shielded cord)
Signal line
between indoor units
Signal line
CNK1
WH
BL
RD
DM
M
RD
WH
For heat recovery 3-pipe systems
(20S) (SVH) (SVG) (SVE)
XB1
XB2
XB3
XB4
1
2
3
4
5
CNT2
RD
+12
BK
WH
BL
CNWR
WH
L
L
Reactor
CNR
WH
+12 1 2
YE
YE
Prepare on site
PIS
Motion sensor
Description
Item
1
2
CNTA
BL
(Remote operation input: volt-free contact)
Prepare on site
1
1
PIS
CNG
BL
2 3
2 3 4
1 2 3 4
※1
WH
BK
RD
WH
RD BK
Option
CNV2
BK
■mark
Closed-end connector
Notes
1.
-----
indicates wiring on site.
2. Use twin core shielded cord(0.75 - 1.25mm
2
) at signal line between indoor unit
and outdoor unit, and signal line between indoor units. 3. Use twin core cord(0.3mm
2
) at remote control line.
See spec sheet of remote control in case that the total len
gth is more than 100m.
4. Do not put signal line and remote control line alongside pow
er source line.
5. Section 1(※1)shows electric circuit of motion sensor(option)
.
Power source 1 Phase
PJG000Z543
Models FDU224KXZE1, 280KXZE1