49
-
'19 • KX-T-310D
1
3
1 2 3 4 5
1 2 3 4 5
3
5
1
M
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
LM1
M
6 7 8 9 10
LM2
11 12 13 14 15 16 17 18 19 20
Power circuit
6 7 8 9 10 11 12
6 7 8 9 10 11 12
X Y
L N
CNU
SM
1
M
2
3
4
5
6
M
1
4
5
6
7
F3
FMi
1
2
3
4
5
6
1
2
1
2
FS
Thi-R1
Thi-R2
Thi-R3
Thi-A
DM
M
1
2
1
2
A
1
2
CNJ3
1
2
3
4
5
6
XR1
XR2
XR3
XR4
CNZ
CND
1
2
3
4
5
Prepare on site
3-pipe systems
CNT2
RD
CNT
WH
YE
OR
RD
CNA
RD
CNTA
CNH
CNI
CNR
WH
RD
RD
RD
WH
CNN
YE
RD
RD
YE
YE
WH
CNK1
WH
WH
RD
X Y
Thc
between indoor units
Remote control
SW1
SW2
SW3
SW4
CNW2
WH
CNJ
WH
WH WH WH WH WH WH WH WH WH WH WH WH
For HA
WH
CNM1
WH
RD
OR
WH
WH
RD
WH
RD
3-pipe systems
Power source line
Earth
Power source line between indoor units
CNW1
WH
CNJ2
WH
CNK2
JSL1
1 2 3 4 5
1 2 3 4 5
CNW0
WH
SW6
SW5
SW7
PIS
1
1
PIS
CNG
2 3
2 3 4
1 2 3 4
WH
RD
WH RD
Option
CNV2
Prepare on site
Drain motor
Fan motor
DM
Float switch
LM1,2
FS
Fuse
Connector
SW6
Indication lamp
SM
SW1 SW2 SW3 SW4
JSL1
SW5-1
SW5-2
SW7-1
FMi
Thi-A Thi-R1,2,3
Thc
OR
Color
Color marks
Meaning of marks
RD WH
Color
Red White Yellow
YE
Description
Item
Motion sensor
Closed-end connector
Notes
1.
-----
indicates wiring on site.
2. Use twin core shielded cord(0.75 - 1.25mm
2
) at signal line between
indoor unit and outdoor unit, and signal line between indoor units.
3. Use twin core cord(0.3mm
2
) at remote control line.
See spec sheet of remote control in case that the total length is more than
100m.
4. Do not put signal line and remote control line alongside power source line.
5. Section 1(※1)shows electric circuit of motion sensor(option
).
Power source 1 Phase
CNA-Z
F1-3
Temperature sensor(Remote control) Temperature sensor(Return air) Temperature sensor(Heat exchanger)
L N
TB1
CNU
BL
WH
RD
Drain motor
Fan motor
DM
Float switch
FS
Connector
SW6
TB1 TB2
Indication lamp
SM
SW1 SW2 SW3 SW4
JSL1
SW5-1
LM1- 4
CNA-Z
SW5-2
SW7-1
FM
i
1,2
Thi-A Thi-R1,2,3
Thc
3-pipe systems
XB1
XB2
XB3
XB4
1
2
3
4
5
CNT2
RD
3-pipe systems
Power source
line
Earth
Power source line between indoor units
Blue Brown
Color
OR
BL BR
BK
White Yellow
Red
WH YE
RD
Control PCB
Power PCB
XR1
XR2
XR3
XR4
Prepare on site
1
2
3
4
5
6
1
3
1 2 3 4 5
1 2 3 4 5
CNW2
WH
CNW1
WH
CNB
WH
CNN
YE
CNT
BL
3
5
CNW0
WH
1
M
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
LM1
M
6 7 8 9 10
1
6 7 8 9 10
LM2
M
11 12 13 14 15
1 5 4 3 2
11 12 13 14 15
LM3
M
16 17 18 19 20
1
16 17 18 19 20
LM4
CNJ2
WH
CNJ
WH
Power circuit
6 7 8 9 10 11 12
6 7 8 9 10 11 12
WH
RD
WH WH WH WH WH WH WH WH WH WH WH WH
BL BL BL BL BL
BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK BK
OR OR OR OR OR BK BK BK BK BK RD RD RD RD RD
SW1
SW2
SW3
SW4
X Y A B
X Y
TB2
WH
BK
BL
RD
Thc
1
2
CNK1
WH
5 4 3 2
2 3 4 5
SM
WH
1
YE
OR
BL
RD
M
2
3
4
5
6
CNA
RD
1
2
3
4
5
6
1
2
1
2
CNH
BK
CNI
BL
FS
Thi
-A
Thi-R1
Thi-R2
Thi-R3
RD
RD
YE
YE
BK
BK
BK
BK
RD
RD
DM
RD
WH
CNR
WH
M
1
2
CNTA
BL
1
2
Remote control
M
1
4
5
6
7
F4
CNM2
BK
M
1
4
5
6
7
F3
CNM1
WH
CNF2
WH
CNF1
WH
RD
BL
BR
OR
WH
RD
BL
BR
OR
WH
RD
BL
BR
OR
WH
RD
BL
BR
OR
WH
FMi1
FMi2
F1,3,4
Description
Item
Fuse
PIS
Motion sensor
Prepare on site
1
1
PIS
CNG
BL
2 3
2 3 4
1 2 3 4
WH
BK
RD
Option
CNV2
BK
SW6
SW5
SW7
CNK2
JSL1
BK
CNZ
For HA
WH
CND
BK
between indoor units
Notes
1.
-----
indicates wiring on site.
2. Use twin core shielded cord(0.75 - 1.25mm
2
) at signal line between
indoor unit and outdoor unit, and signal line between indoor units.
3. Use twin core cord(0.3mm
2
) at remote control line.
See spec sheet of remote control in case that the total length is more than
100m.
4. Do not put signal line and remote control line alongside power source line.
5. Section 1(※1)shows electric circuit of motion sensor(option
).
Temperature sensor(Remote control) Temperature sensor(Return air) Temperature sensor(Heat exchanger)
Power source 1 Phase
Meaning of marks
(4) Ceiling cassette-1 way type (FDTS)
Models FDTS45KXE6F, 71KXE6F
PJC001Z434