46
-
'19 • KX-T-310D
CNT
A
BL
1
2
Thi-A
CNI BL
CNJ1 WH
6
5
4
3
2
1
CNN YE
Thi-R3
Thi-R2
Thi-R1
t°
t°
t°
2
1
CNC WH
CNH BK
1
2
t°
DM
1
2
CNR WH
M
2
1
RD
RD
RD
RD
YE
BK
BK
YE
FS
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
+12
+12
YE
/
GN
BK
BK
RD
WH
LM4
LM1
LM2
LM3
M
M
1
M
M
BK
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
BK
BK
BK
BK
BK
BK
BK
BK
BK
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
E1
CNL BK
3
1
2
BK
BK
BK
Option
(
volt-free contact
)
HS
BK
BK
Remote operation input
BK
BK
BK
BK
BK
BK
BK
BK
BK
BK
RD
RD
RD
RD
RD
RD
RD
RD
RD
RD
CNJ3 WH
PIS
3
1
2
t°
Remote control
Thc
M
CNA RD
CNJ2 GY
AM4
AM1
AM2
AM3
CNM1 WH
F2
CNB BK
CNK1 WH
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
SM
WH
YE
OR
BL
RD
XR1
XR5
CNT BL
For heat recovery 3-pipe systems
(
20S
)
(
SVH
)
(
SVG
)
(
SVE
)
XB1
Prepare on site
XB2
XB3
XB4
XR2
XR3
XR4
1 2 3 4 5 6
CNT2 RD
1 2 3 4 5
X Y A B
X Y
TB2
WH
BK
BL
RD
L N
Power source line
TB1
Connector for branching control of heat recovery 3-pipe systems
CNU BL
WH
RD
Earth
YE
/
GN
1
2
3
4
5
6
+12
+12
(
2.0A
)
※1
M
M
1
M
M
2
3
4
5
1
2
3
4
5
1
2
3
4
5
1
2
3
4
5
WH
WH
WH
WH
WH
WH
WH
WH
WH
WH
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
F1
CNWO WH
1
3
5
YE
/
GN
RD
(
3.15A
)
WH
Power circuit
Indoor unit PCB
1
2
1
2
(
Operation
)
(
Heating
)
(
Thermo ON
)
(
Inspection
)
Remote operation input
(
volt-free contact
)
220-240V
50Hz
220V
60Hz
Power source 1Phase
Signal line between indoor units
Signal line
(
Shielded cord
)
Power source line between indoor units
CNJ4 WH
WH
WH
WH
WH
WH
WH
WH
WH
WH
WH
BL
BL
BL
BL
BL
BL
BL
BL
BL
BL
FMi
M
1
4
5
6
7
BL
RD
BR
OR
WH
CNM2 WH
BL
RD
BR
OR
WH
Operation check,drain motor test run
Temperature sensor
(
Remote control
)
Model capacity setting
SW6,SW7-2
Terminal block
(
Power source
)(□
mark
)
TB1 TB2
Stepping motor
(
For electronic expansion valve
)
SM SW1 SW2
Indoor unit address:tens place Indoor unit address:ones place
SW3 SW4
Automatic adjustment
/
Fixed previous
SW5-1
SW5-2
SW7-1
Thi-A Thi-R1,2,3
Thc
Outdoor unit address:tens place Outdoor unit address:ones place
Indoor unit address:hundreds place
Terminal block
(
Signal line
)(
□
mark
)
Temperature sensor
(
Return air
)
Temperature sensor
(
Heat exchanger
)
version of Superlink protocol
Drain motor
Fan motor
DM
Fuse
F1,2
Connector
CNA
-
Z
FMi
Description
Item
Draft prevention function motor
AM1
-
4
Louver motor
Float switch
LM1
-
4
FS
Indication lamp
(
Red-Inspection
)
LED
・
2
Indication lamp
(
Green-Normal operation
)
LED
・
3
JSL1
Spare Superlink connector change
PIS
Motion sensor
Color marks
Meaning of marks
Mark
Color
Blue
BK BL
Brown Orange
BR OR
Red
RD
Black
Mark
Color
Yellow
WH YE
Gray Yellow
/
Green
GY YE
/
GN
White
Humidity sensor
HS
SW2
SW1
SW4
SW3
SW6
SW7
CNK2
Superlink
(
spare
)
JSL1
BK
LED
・
3
LED
・
2
SW5
Prepare on site
1. indicates wiring on site. 2.Use twin core shielded cord
(
0.75
-
1.25mm
)
at signal line between
2
indoor unit and outdoor unit, and signal line between indoor units.
3.Use twin core cord
(
0.3mm
)
at remote control line.
2
See spec sheet of remote control in case that the total length is more than 100m.
4.Do not put signal line and remote control line alongside power source line.
Notes
5.Draft prevention function
(※
1)
is provided on the panel
TC-PSAE-5A
W
-E only
.
PJF000Z504
(2) Ceiling cassette-4 way compact type (FDTC)
All models