Page 41
MODELS: WD-60C10 / WD-65C10 / WD-73C10 / WD-60638 / WD-60638CA / WD-65638 / WD-65638CA /
WD-73638 / WD-60738 / WD-65738 / WD-73738 / WD-82738 / WD-65838 / WD-73838 / WD-82838
Data Transfer
Service Data is duplicated and stored in separate EEPROMs in two locations.
PWB-MAIN
- Working Service Data for TV operation
OPTICAL ENGINE
- Backup Service Data
The Optical Engine also includes data for the Index Delay setting for color wheel timing determined at the factory.
The PWB-MAIN also includes User and/or ISF settings. The User/ISF data is not backed up on the Engine. However if
used, it can be backed up onto a USB flash drive.
Data Transfer Procedures should be followed…
After PWB-MAIN Replacement:
1.
Restore
Engine Data From Backup (Includes Geometry Data in V43C & V43)
2. Restore Geometry Data From Backup. (V43+ V43++)
3. Restore ISF Settings From Flash Drive. (V43+ V43++) (
Only if backup USB flash drive is available)
.
After OPTICAL ENGINE Replacement:
1.
Restore Index Delay.
2.
Save Engine and Geometry Setting to Backup
Data Transfer Procedure:
V43C & V43
Data Transfer is accomplished by code command rather than on-screen menus.
1. Press <MENU> - Customer Menu will appear
2.
Press <2-4-5-7> - No indication will be displayed.
3. Press the four digit Code for the desired date transfer function. The STATUS LED will turn red while the data
is being transferred.
4. Press <EXIT> to quit.
DATA TRANSFER FUNCTIONS
<MENU> <2-4-5-7> <CODE>
TRANSFER FUNCTION
CODE
WHEN TO USE
Restore Engine Data From Backup
5555
After PWB-Main Replacement
Restore Index Delay
0000
After Optical Engine Replacement
Save Engine and Geometry Settings to Backup
9999
After Optical Engine Replacement