1-4. INSTALLATION DIAGRAM
ACCESSORIES
Check the following parts before installation.
<Indoor unit>
(1) Installation plate
1
(2)
Attachment screws for the installation
plate
4 × 25 mm
5
(3) Wireless remote controller
1
(4) Felt tape (For left or left-rear piping)
1
(5) Remote controller holder
1
(6) Screws for the remote controller holder
3.5 × 16 mm (Black)
2
(7) Battery (AAA) for (3)
2
(8)
$LUFOHDQLQJ¿OWHU
2
FIELD-SUPPLIED PARTS
(A) Indoor/outdoor unit connecting wire*1
1
(B) Extension pipe
1
(C) Wall hole sleeve
1
(D) Wall hole cover
1
(E) Pipe attachment strap
2 to 5
(F) Screw for (E) 4 × 20 mm
2 to 5
(G) Piping tape
1
(H) Putty
1
(I)
Drain hose
(or soft PVC hose, 19/32 in. [15 mm]
inner diameter or hard PVC pipe VP16)
1
(J)
Refrigerant oil
1
(K) Power supply cord*1
1
Units should be installed by licensed contractor according to local code requirements.
Indoor unit
Wall hole
sleeve (C)
Cut off the
extra length.
Pipe attachment
strap (E)
Use the wall hole sleeve (C) to prevent
indoor/outdoor connecting wire (A) from
contacting metal parts in the wall and to
protect the wiring from rodents.
Wall hole cover (D)
Seal the wall hole
gap with putty (H).
Attach the pipe
to wall with pipe at-
tachment strap (E).
Attachment screw (F)
4 in. (100 mm)
or more
14 in. (350 mm)
or more
8 in. (200 mm) *3
or more
4 in. (100 mm)
or more
Unit: inch
Unit: mm
31-1/2
19-11/16
Air inlet
Air outlet
13-9/16 11-1/4
2-3/8
×
13/16 slot
12~12-3/4
1-9/16
800
500
Air inlet
Air outlet
2-10 × 21 slot
344.5
285
150
40
304~325
5-15/16
<06/09/12>
<15/18>
(K)
(I)
(B)
(A)
Unit: inch
Unit: mm
4 in. (100 mm)
or more
14 in. (350 mm)
or more
20 in
. (50
0 mm
) *3
or m
ore
Drain piping for outdoor unit
Install the unit horizontally.
Do not use drain socket in cold regions. Drain may freeze and make the fan stop.
The outdoor unit produces condensate during the heating operation. Select the installation place to ensure to prevent the outdoor unit and/or the grounds from being wet by drain
water or damaged by frozen drain water.
4-7/8 in.
(122.5 mm)
or more
3-3/8 in.
(85
mm) or more
5-11/16 in. (143
mm)
or more for left
/left
rear piping (using
spacer)
2-3/16 in.
(5
6 mm)
or more
5-1/4 in.
(132.5 mm)
or more
33-1/16
13-3/4~14-5/8
19-11/16
Air inlet
Air inlet
Air inlet
Air inlet
Air inlet
6-7/8
15-3/8
13
Air outlet
2-3/8 × 13/16 slot
1-9/16
40
840
175
500
Air inlet
390
330
349~371
Air outlet
2-10 × 21 slot
clear *2
*2
4 in. (100 mm) or more when front
and sides of unit are clear
*3
When any 2 sides of left, right and
rear of unit are clear
clear *2
*2
20 in. (500 mm) or more when front
and sides of unit are clear
*3
When any 2 sides of left, right
and rear of unit are clear
5.9 ft. to 7.5 ft. (1.8 m to 2.3 m)
IURPWKHÀRRULVUHFRPPHQGHG
Note:
*1
Place indoor/outdoor unit connecting wire (A)
and power supply cord (K) at least 3 ft. (1 m)
away from the TV antenna wire.
After the leak test, apply insulating material
tightly so that there is no gap.
When the piping is to be attached to a wall
comprised of tin plate or metal netting, use
chemically treated wooden piece 25/32 in.
(20 mm) or thicker between the wall and the
piping, or wrap insulation vinyl tape 7 to 8
turns around the piping.
To use existing piping, perform COOL opera-
tion for 30 minutes and pump down before
removing the old air conditioner. Remake
ÀDUH DFFRUGLQJ WR WKH GLPHQVLRQ IRU QHZ
refrigerant.
Note:
• The dimensions indicated in the arrows (
) above
show the required space to guarantee performance of
the air conditioner. Install the outdoor unit where the
maximum possible space can be provided, consider-
ing later relocation, services, or repairs.
7KHFRROLQJKHDWLQJSHUIRUPDQFHDQGWKHHI¿FLHQF\RI
power usage may fall about 10% at the place where
short cycle is likely occur due to poor ventilation.
Installing the air outlet guide (optional) can improve
performances.
• If air from the outlet blows against the wall, it may
cause stains on the wall.
Do not take in the outlet air
discharged by other units directly.
15-3/4 in. or more
(400 mm or more)
39-3/8 in. or more
(1000 mm or more)
4 in. (100 mm)
or more