10 TROUBLESHOOTING
<Check code displayed by self-diagnosis and actions to be taken for service (summary)>
Present and past check codes are logged, and they can be displayed on the control board of outdoor unit. Actions to be taken
for service, which depends on whether or not the trouble is reoccurring in the field, are summarized in the table below. Check
the contents below before investigating details.
10-1. TROUBLESHOOTING
Unit conditions at service
Check code
Actions to be taken for service (summary)
The trouble is reoccurring.
Displayed
Judge the problem and take a corrective action according
to “10-3. SELF-DIAGNOSIS ACTION TABLE”.
Not displayed
Conduct troubleshooting and ascertain the cause of the
trouble according to “10-4. TROUBLESHOOTING BY
INFERIOR PHENOMENA”.
The trouble is not reoccurring.
Logged
1.
Consider the temporary defects such as the work of
protection devices in the refrigerant circuit including
compressor, poor connection of wiring, noise, etc.
Re-check the symptom, and check the installation
environment, refrigerant amount, weather when the
trouble occurred, matters related to wiring, etc.
2.
Reset check code logs and restart the unit after finishing
service.
3.
There is no abnormality in electrical component, controller
board, remote controller, etc.
Not logged
1.
Re-check the abnormal symptom.
2.
Conduct troubleshooting and ascertain the cause of the
trouble according to “10-4. TROUBLESHOOTING BY
INFERIOR PHENOMENA”.
3.
Continue to operate unit for the time being if the cause is
not ascertained.
4.
There is no abnormality concerning of parts such as
electrical component, controller board, remote controller,
etc.