46
PEAD-RP35EA2 PEAD-RP50EA PEAD-RP60EA PEAD-RP71EA
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
ON
OFF
1 2 3 4 5
5
4
3
2
1
OFF
ON
50EA
60EA
71EA
35EA2
Capacity cord
switch
Model selection
switch
SW2
SW1
MODELS
TO OUTDOOR UNIT
TO MA-REMOTE
CONTROLLER
DC8.7-13V
I.B.
X6
X4
X5
X1
ZNR
FUSE
P.B.
CN31
1
3
DS
INSIDE SECTION OF CONTROL BOX
B
L
U
B
L
U
B
L
U B
L
U
TB5
(RED)
6
4
3
5
2
1
C
MF
X6
X5
X4
X1
(RED)
CNDK
(BLU)
CNP
(WHT)
FAN
1
Y
L
W
O
R
N
(ORN)
3
1
CND
2
1
(RED)
LED1
LED2
LED3
CN2L
OFF
ON
SWE
SW2
SW1
(RED)
(WHT)
P
N
K
P
N
K
B
L
K
B
L
K
W
H
T
B
L
K
B
L
K
W
H
T
W
H
T
W
H
T
1
2
3
1
CN2S
CNSK
(WHT)
(RED)
YLW
ORN
BRN
B
R
N
O
R
N
(BLU)
WHT
BLK
CN2D
(WHT)
(BLU)
(RED)
(WHT) (BLK)
(WHT)
(WHT)
(WHT)
(YLW)
(WHT)
(WHT)
DP
6
4
3
5
2
1
2
1
TB4
S3
S1
S2
2
1
3
3
1
6
4
3
5
2
1
MF
C
1 2
CN24
3
2
1
1 2 3
1 2
1 2
1 2
TH5
TH2
TH1
1
2
CN3C
3
1
1
3
7 5
CN22
CN20
CN21
CN29
CN31
CN90
CN41
CN51
CN32
2
1
1 2 3 4 5 6 7 8 9
4
3
2
1
4 5
3
2
1
<PEAD-RP71•100•125•140EA, 100EA2>
External static
pressure 130Pa
<PEAD-RP71•100•125•140EA, 100EA2>
External static pressure 70Pa
<PEAD-RP35•50•60EA, 35EA2>
External static
pressure 70Pa
Optional parts
Optional parts
<PEAD-RP35•50•60EA, 35EA2>
External static
pressure 30Pa
(OPTIONAL PARTS)
DRAIN PUMP
RELAY(DRAIN PUMP)
X1
CONNECTOR(WIRELESS)
DP
DS
TRANSMISSION(INDOOR•OUTDOOR)
LED3
SWITCH(MODEL SELECTION)
SW1
POWER SUPPLY(REMOTE CONTROLLER)
LED2
LED1 POWER SUPPLY(I.B.)
CN90
CN51 CONNECTOR(CENTRALLY CONTROL)
CN24 CONNECTOR(HEATER)
VARISTOR
FUSE(T6.3AL250V)
ZNR
FUSE
INDOOR POWER BOARD
P.B.
COND./EVA. TEMP. THERMISTOR
(0
/15k
Ω
, 25
/5.4k
Ω
DETECT)
PIPE TEMP. THERMISTOR/LIQUID
(0
/15k
Ω
, 25
/5.4k
Ω
DETECT)
INTAKE AIR TEMP. THERMISTOR
(0
/15k
Ω
, 25
/5.4k
Ω
DETECT)
TERMINAL BLOCK(REMOTE CONTROLLER)
FAN MOTOR
CAPACITOR(FAN MOTOR)
DRAIN SENSOR
DRAIN PUMP
TH5
TH2
TH1
TB5
(INDOOR/OUTDOOR CONNECTING LINE)
TERMINAL BLOCK
TB4
MF
C
NAME
NAME
NAME
[LEGEND]
RELAY(FAN MOTOR)
RELAY(FAN MOTOR)
SWITCH(CAPACITY CORD)
CONNECTOR(HA TERMINAL-A)
CONNECTOR(REMOTE SWITCH)
INDOOR CONTROLLER BOARD
RELAY(FAN MOTOR)
SWITCH(EMERGENCY OPERATION)
CONNECTOR(LOSSNAY)
X6
X5
X4
SWE
SW2
CN41
CN32
CN2L
I.B.
SYMBOL
SYMBOL
SYMBOL
NOTES:
1. Since the outdoor side electric wiring may change, be sure to check the outdoor
unit electric wiring diagram for servicing.
2. Indoor and outdoor connecting wires have poIarities, make sure to match
terminal numbers (S1, S2, S3) for correct wirings.
3. Symbols used in wiring diagram above are,
: Connector, : Terminal (block).
4. The wiring between MA-Remote controller and TB5 is included in the package.