13
Model name
Indoor unit
PEAD-RP60GA
PEAD-RP71GA
Outdoor unit
SUZ-KA60VA
SUZ-KA71VA
Cooling
Capacity
Btu/h
19,400
24,200
kW
5.7(1.1 - 6.3)
7.1(0.9 - 8.1)
Total input
kW
2.03
2.53
EER
2.81
2.81
Energy label class
C
C
SHF
0.82
0.81
Heating
Capacity
Btu/h
23,900
27,300
kW
7.0(0.9 - 8.0)
8.0(0.9 - 10.2)
Total input
kW
2.05
2.49
COP
3.41
3.21
Energy label class
B
C
Booster heater
kW
—
—
Power supply
Phase
:
1
Cycle
Hz
50
Voltage
V
230
Breaker size
A
20
Indoor unit
Air flow
CMM
16.5 - 21
20 - 25
(Low - High)
CFM
582 - 741
706 - 883
External static pressure
Pa
10/50/70
Sound level
dB(A)
33 - 37/35 - 40/36 - 42 35 - 38/37 - 41/37 - 43
(Low - High)
(10/50/70Pa)
(10/50/70Pa)
External finish
Galvanized sheets
Dimension
W : mm
1171
D : mm
740
H : mm
275
W : inch
46 - 1/8
D : inch
29 - 1/8
H : inch
10 - 13/16
Weight
kg
42
lbs
93
Unit drain pipe
R1(External thread)
Outdoor unit
Air flow at cooling
CMM
27.5 - 49
27.5 - 49
(Low - High)
CFM
970 - 1,730
970 - 1,730
Air flow at heating
CMM
36.8 - 49
36.8 - 49
(Low - High)
CFM
1,300 - 1,730
1,300 - 1,730
Sound level at cooling
dB(A)
51 - 53
51 - 53
(Low - High)
Sound level at heating
dB(A)
53 - 55
53 - 55
(Low - High)
External finish
Ivory Munsell 3.0Y 7.8/1.1
Dimension
W : mm
840
840
D : mm
330
330
H : mm
850
850
W : inch
33 - 1/16
33 - 1/16
D : inch
13
13
H : inch
33 - 7/16
33 - 7/16
Weight
kg
53
58
lbs
117
128
Refrigerant pipe size
Gas side O.D.
mm
15.88
15.88
inch
5/8
5/8
Liquid side O.D.
mm
6.35
9.52
inch
1/4
3/8
Refrigerant pipe length
Height difference
m
Max. 30
Max. 30
Length
m
Max. 30
Max. 30
NOTE:
1.
Rating conditions (ISO T1)
Cooling Indoor : D.B. 27
(80°F) W.B. 19
(66°F)
Outdoor : D.B. 35
(95°F) W.B. 24
(75°F)
Heating Indoor : D.B. 20
(68°F)
Outdoor : D.B. 7
(45°F)
W.B. 6
(43°F)
Refrigerant piping length (one way) : 5m (16ft.)
2.
Guaranteed operating range
Indoor
Outdoor
Cooling
Upper limit
32°C D.B. , 23°C W.B.
43°C D.B.
KA60, KA71
Lower limit
21°C D.B. , 15°C W.B.
-15°C D.B.
Heating
Upper limit
27°C D.B.
24°C D.B. , 18°C W.B.
Lower limit
20°C D.B.
-10°C D.B. ,-11°C W.B.
4.
Above data are based on the indicated voltage.
Indoor unit
Single phase, 230V 50Hz
Single phase, 230V 50Hz
Outdoor unit
3.
Guaranteed voltage
198~264V, 50Hz