EN-24
Indicators
This projector has two indicators, each of which shows the operation condition of the projector.
The following offer solutions to possible problems. If these problem persist, turn the projector off and consult your dealer.
Normal condition
Abnormal condition
POWER
STATUS
CONDITION
NOTE
Stand-by
The projector is in good condition.
The projector is shutting and the fan motor is cooling the lamp for
shutdown. Do not unplug the power cord or turn the power off
before the POWER LED changes to flashing. The fan motor will
turn off when the lamp has been cooled.
STATUS indicator
POWER indicator
Blinking green
Off
Steady green
Steady green
Steady amber
Steady amber
POWER
STATUS
CONDITION
POSSIBLE SOLUTION
The projector system has some problems with its fan, so the pro-
jector cannot start up.
Contact your dealer.
The lamp has reached its end of life and must be changed soon.
The lamp will continue to operate until it fails. Change the lamp. If
the lamp is off, then the ballast will become malfunction.
(during
power on)
Replace the lamp and reset the lamp operation time.
Temperature is too high. The lamp will turn off. The fan motor is
cooling the lamp.
Wait until the lamp cools down, and the projector
enters stand-by mode.
The lamp ignition failed.
Replace the lamp and reset the lamp operation time.
Temperature is too high or temperature's sensor is error during
stand-by mode.
•
Wait for 1 hour until the lamp cools down, and
turn the power back on.
•
If the temperature is still high after 1 hour, con-
tact your dealer.
Steady green
Blinking green
Steady amber
Steady green
Steady green
Blinking red
Steady amber
Off
Blinking green
Blinking red