OUTDOOR UNIT
B-106
TROUBLESHOOTING
S series
OUTDOOR
UNIT
Once
3 times
4 times
Lighting
Goes out
Goes out
Goes out
Lighting
IPM protection
Lock protection
Fin temperature overheat
protection
P.C.boad temperature
overheat protection
Discharge temperature
overheat protection
HPS protection
High pressure protection
(Overheat protection)
Low discharge
temperature protection
Outdoor fan protection
Outdoor power system
Overcurrent protection
Fin temperature/P.C.
board temperature
overheat
Refrigerant system
High pressure
protection
Low discharge
temperature
Outdoor fan
Outdoor power
system
Outdoor LED indication
LED1 LED2
Abnormal point
(Failure mode)
Details of abnormal
Detecting method
Check point
When overcurrent is detected after
30 seconds of compressor start-up.
When overcurrent is detected within 30
seconds after the compressor gets started.
When the fin temperature exceeds 87
during operation.
When the P.C. board temperature exceeds
70
during operation.
When discharge temperature exceeds
116
.
When high-pressure is detected with the
high-pressure switch (HPS) during operation.
When the indoor coil thermistor (TH5)
exceeds 70
in HEAT mode.
When the outdoor heat exchanger thermistor
exceeds 70
in COOL mode.
When the frequency of the compressor is
kept 80Hz or more and discharge
temperature is kept under 39
for more
than 20 minutes.
When outdoor fan has stopped within 30
seconds 3 times in a row after outdoor fan
start -up,unit stops.
When IPM protection stop or lock
protection stop is continuously
performed 3 times within 1 minute after
the compressor get started, or when
converter protection stop or bus-bar
voltage protection stop is continuously
performed 3 times within 3 minutes after
start-up.
• Check the connection of the compressor
connecting wire.
• Check the inverter/ compressor.
• Check the stop valve.
• Check around outdoor unit.
• Check outdoor unit air passage.
• Check the outdoor fan motor.
• Check refrigerant circuit and refrigerant
amount.
• Check the LEV.
• Check the outdoor thermistors.
• Check refrigerant circuit and refrigerant
amount.
• Check the stop valve.
• Check refrigerant circuit and refrigerant
amount.
• Check the LEV.
• Check the outdoor fan motor.
• Reconnect compressor connector.
• Check the inverter/ compressor.
• Check the stop valve.
• Check the PAM module.
The blinking frequency shows the number of times the LED blinks after every 2.5-second OFF.
(Example) When the blinking frequency is “2”.
ON
OFF
2.5-second OFF
2.5-second OFF
0.5-second ON
0.5-second ON