3
- 3
3.3 I/O Signals to the Programmable Controller CPU
3.3.1 I/O signal list
3
SPECIFICATIONS
3.3
I/O Signals to the Programmable Controller CPU
3.3.1
I/O signal list
The following table shows the I/O signals from the QD63P6 to the programmable controller
CPU.
Note that that I/O numbers (X/Y) and I/O addresses mentioned in this and the subsequent
chapters are assumed when the QD63P6 is mounted to the null I/O slot on the main base
unit.
Table 3.4 I/O signal list
Input signal (Signal direction QD63P6 Programmable
controller CPU)
Output signal (Signal direction Programmable controller
CPU
QD63P6)
Device
No.
Signal name
Device
No.
Signal name
X00
Module READY
Y00
Reserved
X01
CH1
Counter value large
Y01
CH1
Coincidence signal reset command
X02
Counter value coincidence
Y02
Preset command
X03
Counter value small
Y03
Subtraction count command
X04
Reserved
Y04
Count enable command
X05
Reserved
Y05
Periodic pulse counter start command
X06
CH2
Counter value large
Y06
CH2
Coincidence signal reset command
X07
Counter value coincidence
Y07
Preset command
X08
Counter value small
Y08
Subtraction count command
X09
Reserved
Y09
Count enable command
X0A
Reserved
Y0A
Periodic pulse counter start command
X0B
CH3
Counter value large
Y0B
CH3
Coincidence signal reset command
X0C
Counter value coincidence
Y0C
Preset command
X0D
Counter value small
Y0D
Subtraction count command
X0E
Reserved
Y0E
Count enable command
X0F
Reserved
Y0F
Periodic pulse counter start command
X10
CH4
Counter value large
Y10
CH4
Coincidence signal reset command
X11
Counter value coincidence
Y11
Preset command
X12
Counter value small
Y12
Subtraction count command
X13
Reserved
Y13
Count enable command
X14
Reserved
Y14
Periodic pulse counter start command
X15
CH5
Counter value large
Y15
CH5
Coincidence signal reset command
X16
Counter value coincidence
Y16
Preset command
X17
Counter value small
Y17
Subtraction count command
X18
Reserved
Y18
Count enable command
X19
Reserved
Y19
Periodic pulse counter start command
X1A
CH6
Counter value large
Y1A
CH6
Coincidence signal reset command
X1B
Counter value coincidence
Y1B
Preset command
X1C
Counter value small
Y1C
Subtraction count command
X1D
Reserved
Y1D
Count enable command
X1E
Reserved
Y1E
Periodic pulse counter start command
X1F
Error occurrence
Y1F
Reserved