7
OCH668B
PUMY-SP
・
VKM.TH(-BS),PUMY-SP
・
YKM.TH(-BS)
cannot connect 52/ 32 series.
PUMY-SP
・
VKMR1.TH(-BS),PUMY-SP
・
YKMR1.TH(-BS)
cannot connect 31/32/51/52 series.
PAC-MK5*BC
5-branches
(MAX. 5 units)
Branch box
Number of branches
Branching pipe
components
CMY-Y62-G-E
Branch header
(2-branches)
CMY-Y64-G-E
Branch header
(4-branches)
CMY-Y68-G-E
Branch header
(8-branches)
Citymulti indoor units*
2
CONNECTION KIT
PAC-LV11M-J
M series indoor unit
MA
remote
controller
M series
remote
controller
M series
S series
P series
indoor units*
2
MA
remote
controller
*
1
When connecting 7 indoor units via branch box, connectable citymulti indoor units are 3; connecting 8 indoor units
via branch box, connectable citymulti indoor units are 2.
*
2
Refer to “2-1. UNIT CONSTRUCTION” or “2-2. UNIT CONSTRUCTION (BRANCH BOX SYSTEM)”, for more detail.
PAC-MK3*BC
3-branches
(MAX. 3 units)
2-3. UNIT CONSTRUCTION (MIXED SYSTEM)
Outdoor unit
4.5HP
5HP
6HP
PUMY-SP112VKM
(
R1).TH(-BS)
PUMY-SP112YKM(R1).TH(-BS)
PUMY-SP125VKM(R1).TH(-BS)
PUMY-SP125YKM(R1).TH(-BS)
PUMY-SP140VKM(R1).TH(-BS)
PUMY-SP140YKM(R1).TH(-BS)
Applicable
indoor unit
Capacity
City multi indoor unit
Type 15 to Type 140
Via branch box
kW unit: Type 15 to Type 100
Number
of units
Via branch box
City multi indoor
Via branch box
City multi indoor
Via branch box
City multi indoor
1 branch box
-
5
5
5
5
5
5
2 branch boxes
7 or 8*
1
3 or 2*
1
8
3
8
3
Total system capacity range
6.3 to 16.2 kW
7.1 to 18.2 kW
8.0 to 20.2 kW