102
OCH668B
The black square (■) indicates a switch position.
Continue
to
the
next
page
8-3. INTERNAL SWITCH FUNCTION TABLE
Switch
Step
Function
Operation
in
Each
Switch
Setting
Remarks
Purpose
Additional Information
ON
OFF
When
to
Set
SWU1
ones digit
SWU2
tens digit
Rotary switch
Before turning
the
power
ON
<Initial settings>
SW1
Digital
Display Switch
1–8
Can be set either during operation or not.
<Initial settings>
T
o
display
outdoor
unit's
information
to
the LED on outdoor multi controller circuit board. Refer to "8-8. OUTDOOR UNIT
INFORMA
TION DISPLA
Y".
SW2
Function
Switch
1
Selects
operating
system
startup
With centralized controller
Without centralized controller
Before turning
the
power
ON
<Initial settings>
Turn ON when the centralized controller is connected to the outdoor unit.
• SW2-1 must be turned ON if a central controller is connected to the system.
An
example of this would be a
TC-24, EB50A,
AG150,
AE50 or
AE200. If SW2-1 is not turned
on, while using a central controller
, in rare
circumstances problems may be encountered such as indoor units not responding to group commands.
Therefore, turning SW2-1 ON is
recommended if a central controller is used. • Group setting of 2 or more
A-IC units
which is connected to branch box via centralized controller is not allowed.
2
Connection
Information
Clear
Switch
Clear
Do not clear
When relocating units or connecting additional units.
—
3
Abnormal
data
clear
switch
input
Clear abnormal data
Normal
OFF to ON any time after the power is turned on.
To delete an error history
.
4
Pump
down
Run adjustment mode
Normal
During
compressor
running
To facilitate outdoor unit the pumping down operation. Frequency = Fixed to 65 Hz
Indoor-Electronic expansion valve = Fully open
Outdoor fan step = Fixed to 10
Please refer to a section referring to the pumping down on outdoor units Installation Manuals. It might not be possible to collect all the refrigerant if the amount is excessive.
5
—
—
—
—
—
—
6
—
—
—
—
—
—
SW3
T
rial
operation
1
ON/OFF from outdoor unit
ON
OFF
Any time after the power is turned ON.
<Initial settings>
—
—
2
Mode setting
Heating
Cooling
—
—
SW4/ SW8
Model
Switch
1–6
Before
the
power
is turned ON.
<Initial settings>
Set
for
each
capacity
.
—
—
SWU2
(tens digit)
0
1 2
3 4
5
67
89
SWU1
(ones digit
)
0
1 2
3 4
5
67
89
1
ON OFF
2
3
4
5
6
7
8
SWU2
(tens digit)
0
1 2
3 4
5
67
89
SWU1
(ones digit
)
0
1 2
3 4
5
67
89
1
ON OFF
2
3
4
5
6
7
8
1
ON OFF
2
3
4
5
6
1
ON OFF
2
PUMY-SP112VKMR1.TH
PUMY-SP125VKMR1.TH
PUMY-SP140VKMR1.TH
PUMY-SP112YKMR1.TH
PUMY-SP125YKMR1.TH
PUMY-SP140YKMR1.TH
PUMY-SP112VKMR1.TH-BS PUMY-SP125VKMR1.TH-BS PUMY-SP140VKMR1.TH-BS
PUMY-SP112YKMR1.TH-BS PUMY-SP125YKMR1.TH-BS PUMY-SP140YKMR1.TH-BS
MODELS
PUMY-SP112YKM
PUMY-SP125YKM
PUMY-SP140YKM
SW4
ON OFF
1
2
3
4
5
6
ON OFF
1
2
3
4
5
6
ON OFF
1
2
3
4
5
6
SW2
ON OFF
5
6
ON OFF
5
6
ON OFF
5
6
SW8
ON OFF
1
2
ON OFF
1
2
ON OFF
1
2
SW9
ON OFF
3
4
ON OFF
3
4
ON OFF
3
4
MODELS
PUMY-SP112VKM
PUMY-SP125VKM
PUMY-SP140VKM
SW4
ON OFF
1
2
3
4
5
6
ON OFF
1
2
3
4
5
6
ON OFF
1
2
3
4
5
6
SW2
ON OFF
5
6
ON OFF
5
6
ON OFF
5
6
SW8
ON OFF
1
2
ON OFF
1
2
ON OFF
1
2
SW9
ON OFF
3
4
ON OFF
3
4
ON OFF
3
4