11
OCH668G
Model
PUMY-SP112YKM(-BS)
PUMY-SP112YKM-ET(-BS)
PUMY-SP112YKM-ER(-BS)
PUMY-SP125YKM(-BS)
PUMY-SP125YKM-ET(-BS)
PUMY-SP125YKM-ER(-BS)
PUMY-SP140YKM(-BS)
PUMY-SP140YKM-ET(-BS)
PUMY-SP140YKM-ER(-BS)
Power source
3-phase
380-400-415 V, 50 Hz; 3-phase 380 V, 60 Hz
Cooling capacity
(Nominal)
kW
*1
12.5
14.0
15.5
kcal/h
*1
10,750
12,040
13,330
Btu/h
*1
42,650
47,768
52,886
Power input
kW
3.10
3.84
4.70
Current input
A
4.96
4.71
4.54
6.14
5.83
5.62
7.52
7.14
6.88
COP
kW/kW
4.03
3.65
3.30
Temp. range of cooling
Indoor temp.
W.B.
15 to 24°C
Outdoor temp. D.B.
-5 to 52°C
*3
,
*4
Heating capacity
(Nominal)
kW
*2
14.0
16.0
16.5
kcal/h
*2
12,040
13,760
14,190
Btu/h
*2
47,768
54,592
56,298
Power input
kW
3.17
3.90
4.02
Current input
A
5.07
4.82
4.64
6.24
5.93
5.71
6.43
6.11
5.89
COP
kW/kW
4.42
4.10
4.10
Temp. range of heating
Indoor temp.
D.B.
15 to 27°C
Outdoor temp. W.B.
-20 to 15°C
Indoor unit
connectable
Total capacity
50 to 130% of outdoor unit capacity
Model/
Quantity
CITY MULTI
P10-P140/12
P10-P140/12
P10-P140/12
Branch box
*5
P15-P100/8
P15-P100/8
P15-P100/8
Mixed
system
Branch box
1 unit
*5
CITY MULTI
P10-P140/5
P10-P140/5
P10-P140/5
Branch box
P15-P100/5
P15-P100/5
P15-P100/5
Branch box
2 units
*5
CITY MULTI
P10-P140/3
P10-P140/3
P10-P140/3
Branch box
P15-P100/8
P15-P100/8
P15-P100/8
Sound pressure level
(measured in anechoic room)
dB <A>
52/54
53/56
54/56
Power pressure level
(measured in anechoic room)
dB <A>
72/74
73/76
74/76
Refrigerant piping
diameter
Liquid pipe
mm (inch)
9.52 (3/8)
Gas pipe
mm (inch)
15.88 (5/8)
Fan
*2
Type × Quantity
Propeller Fan × 1
Airflow rate
m³/min
77
83
83
L/s
1283
1383
1383
cfm
2719
2931
2931
Control, Driving mechanism
DC control
Motor output
kW
0.20 × 1
External static press.
0 Pa/30 Pa
*6
Compressor
Type × Quantity
Twin rotary hermetic compressor × 1
Manufacturer
Mitsubishi Electric Corporation
Starting method
Inverter
Capacity
control
%
Cooling 26 to 100
Heating 20 to 100
Cooling 24 to 100
Heating 18 to 100
Cooling 21 to 100
Heating 17 to 100
Motor output
kW
3.1
3.5
3.7
Case heater
kW
0
Lubricant
FV50S (1.4 litter)
External finish
Galvanized Steel Sheet Munsell No. 3Y 7.8/1.1
External dimension H × W × D
mm
981 × 1,050 × 330(+40)
inch
38-5/8 × 41-3/8 × 13 (+1-37/64)
Protection
devices
High pressure protection
High pressure Switch
Inverter circuit (COMP./FAN)
Overcurrent detection, Overheat detection(Heat sink thermistor)
Compressor
Compressor thermistor, Overcurrent detection
Fan motor
Overheating, Voltage protection
Refrigerant
Type × original charge
R410A 3.5 kg
Control
Linear expansion valve
Net weight
kg (lb)
94 (207)
*7
Heat exchanger
Cross Fin and Copper tube
HIC circuit (HIC: Heat Inter-Changer)
HIC circuit
Defrosting method
Reversed refrigerant circuit
Drawing
External
RK01B171
Wiring
BH79J996
Standard
attachment
Document
Installation Manual
Accessory
Grounded lead wire
Optional parts
Joint: CMY-Y62-G-E
Header: CMY-Y64/68-G-E
Remarks
Unit converter
kcal/h = kW × 860
Btu/h = kW × 3,412
cfm = m³/min × 35.31
lb = kg/0.4536
Above specification data is
subject to rounding variation.
*1
Nominal cooling conditions
27°C D.B./19°C W.B. [81°F D.B/66°F W.B.]
35°C D.B. [95°F D.B.]
7.5 m [24-9/16 ft]
0 m [0 ft]
*2
Nominal heating conditions
20°C D.B. [68°F D.B.]
7°C DB/6°C W.B. [45°F D.B./43°F W.B.]
7.5 m [24-9/16 ft]
0 m [0 ft]
Indoor :
Outdoor :
Pipe length :
Level difference :
*3
10 to 52°C(D.B):
When connecting PFFY-P20/25/32VCM, PKFY-P15/20/25VBM, PKFY-P10/15/20/25/32VLM, PFFY-
P20/25/32VKM, PFFY-P20/25/32VLE(R)M(M), and M series, S series, and P series type indoor unit.
*4
−15 to 52
°C(D.B):
When using an optional air protect guide [PAC-SH95AG-E]. However, this condition does not apply to the indoor unit
listed in *3.
*5
At least two indoors must be connected when using branch box.
*6
It is possible to set the External static pressure to 30 Pa by Dip Switch.
*7
95 (209), for PUMY-SP112/125/140YKM(R1
/R2).TH-BS.
Notes : 1. Nominal conditions *1, *2 are subject to ISO 15042.
2. Due to continuing improvement, above specifications may be subject to change without notice.