17
PUHZ-HRP100YHA2 PUHZ-HRP125YHA2
LEV-A
(WHT)
6
1
3
LEV-B
(RED)
6
1
CNVMNT
(WHT)
CN4
(WHT)
CNMNT
(WHT)
3
1
5
1
CN5 (WHT)
3 1
LED2
SW1
SW11
SW12
LED3
LED4
TB7
LED1
LED5
5
1
2
5
1
CND
(WHT)
CN2M (WHT)
M-NET
When M-NET adapter is connected
7
1
2
1
2
1
1 2
3 4
CNS
(WHT)
1
3
21S4
(GRN)
MF1
TRANS
MF2
CNF1
(WHT)
CNF2
(WHT)
1
3
CNDC
(PNK)
CN2
(WHT)
CNAC
(WHT)
1
3
SV2
(BLU)
X55
X51
X52
1
3
SS
(WHT)
+
--
--
+
+
+
+
+
ACL1
ACL2
ACL3
ACL4
CN7
(WHT)
CN2
(WHT)
TB-P2
CB1
CB2
CK
TB-C1
L3-OU
L2-OU
L1-OU
L3-A2
L2-A2
L1-A2
L1-A1
L1-IN
N-IN
CK-OU
TB-N1
TB-W
BLK
WHT
RED
BLK
WHT
RED
BLK
BLU
WHT
RED
RED
RED
RED
RED
BLK
BLU
GRN/YLW
WHT
RED
TB-V
TB-U
TB-L3
TB-L2
TB-L1
W
V
U
MC
CN4
(WHT)
CNAC1
(WHT)
CN7 (WHT)
WHT
WHT
CN5
(RED)
CNCT
(RED)
CNAC2
(RED)
CNL
(BLU)
CNDC
(PNK)
RS
P . B .
C . B .
N . F .
CONV.B.
LO1
GD1
GD3
LO2
LO3
NO
LI1
LI2
LI3
NI
TB1
TB2
POWER SUPPLY
3N~
400V 50Hz
INDOOR
UNIT
1
F2
F1
F3
F4
TH7/6
(
RED)
63H
(
YLW
)
TH3
(
WHT)
TH4
(
WHT)
TH7
TH3 TH4
4
1
2
1
TH33
(
YLW)
TH33
3
t°
1
2 1
3
1
3
1
t°
TH6
t°
t°
t°
63H
2
2
1
7
2
3
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
OFF
ON
100Y
MODEL
SW6
2. SW5 -1 to 5 : Function Switch
SW5-6
2
OFF
ON
OFF
ON
125Y
OFF
ON
1 2 3 4 5 6
1 2 3 4 5 6
3
7
RED
WHT
BLK
BLK
BLK
WHT
BRN
7
1
7
1
7
1
RED
X52A
RED
3
3
1
3
1
2
1
LEV-A
LEV-B
M
M
LED1
LED2
CNM
(
WHT
)
1
14
1
3
1
5
3
5
CNDM (WHT
)
CN51 (WHT
)
SW7
SW6
SW1
SW9
CN31
1
2
SW5
SW8
SW4
SWP
SV
21S4
A B S
MS
3
~
+
+
--
1
3
3
1
3
1
U
U
U
U
U
L1
L2
L3
N
S1
S2
S3
YLW
ORN
BRN
3
1
MS
3
~
MS
3
~
2
2
2
2
M-NET ADAPTER
BLK
BLK
BLK
BLU
U
TH32
(
BLK)
TH32
2
t°
1
63L
(
RED
)
3
1
63L
5
LEV-C
(
BLU
)
6
1
LEV-C
M
5
63HS
63HS
(
WHT)
TB1
MC
MF1, MF2
21S4
63H
TH4
TH6
TH7
LEV-A, LEV-B, LEV-C
ACL1~ACL4
Terminal Block<Power Supply>
TB7
Terminal Block<M-NET connection >
CN5
Connector<Transmission>
CND
Connector<Power Supply>
CN2M
Connector<M-NET communication>
SW1
Switch<Status of communication>
SW11
Switch<Address setting: 1s digit>
SW12
Switch<Address setting: 10s digit >
LED1
LED<Power Supply: DC5V>
LED2
LED<Connection to Outdoor Unit>
LED3
LED<Transmission: Sending>
LED4
LED<Transmission: Receiving>
LED5
LED<Power Supply: DC12V>
TB2
Terminal Block<Indoor/Outdoor >
Motor for Compressor
Fan Motor
Solenoid Valve (Four-Way Valve)
High Pressure Switch
63L
Low Pressure Switch
SV
Solenoid Valve (Bypass Valve)
Thermistor<Discharge>
Thermistor<Outdoor 2-Phase Pipe>
Thermistor<Outdoor>
Electronic Expansion Valve
Reactor
RS
Rush Current Protect Resistor
CB1, CB2
Main Smoothing Capacitor
CK
Capacitor
Power Circuit Board
Connection Terminal<U/V/W-Phase>
P.B.
TB-U/V/W
Noise Filter Circuit Board
Connection Terminal<L1/L2/L3/N-Power Supply>
N.F.
LI1/LI2/LI3/NI
Connection Terminal<L1/L2/L3/N-Power Supply>
LO1/LO2/LO3/NO
Controller Circuit Board
Connector<Emergency Operation>
Switch<Function Setup>
SW8
CN31
C.B.
Connection Terminal
N-IN
Connection Terminal
CK-OU
Connection Terminal<Ground>
GD1, GD3
Connection Terminal<L1-Power Supply>
L1-A1/IN
SYMBOL
[LEGEND]
M-NET ADAPTER
NAME
SYMBOL
NAME
SYMBOL
NAME
Connection Terminal
TB-P2
Switch
SW9
Switch<Pump Down>
SWP
Connection Terminal<L1-Power Supply>
L1-A2/OU
Connection Terminal<L2-Power Supply>
L2-A2/OU
Connection Terminal<L3-Power Supply>
L3-A2/OU
Converter Circuit Board
CONV.B.
Switch<Forced Defrost, Defect History Record
Reset, Refrigerant Address>
Switch<Function Switch>
Switch<Function Setup>
SW1
SW5
SW7
Switch<Test Operation>
SW4
LED1, LED2 LED<Operation Inspection Indicators>
CNM
Connector<A-Control Service Inspection Kit>
CNDM
Connector
< Connection for Option(Contact Input)>
SS
Connector< Connection for Option>
X51,X52,X55 Relay
Fuse<T6.3AL250V>
F1~F4
Connection Terminal
TB-C1
Connection Terminal
TB-N1
52C Relay
X52A
Switch<Model Select>
SW6
Connection Terminal<L1/L2/L3-Power Supply>
TB-L1/L2/L3
63HS
High Pressure Sensor
TH3
Thermistor<Liquid>
TH32
Thermistor<Suction>
TH33
Thermistor<Ref. check>
+
1. MODEL SELECT
The black square (
■
) indicates a switch position.
OCH425D