17
Having trouble?
Here is the solution. (Unit is operating normally.)
Noise is louder than specifications.
Nothing appears in the wireless remote controller display, the display is
faint, or signals are not received by the indoor unit unless the remote con-
troller is close.
The operation lamp near the receiver for the wireless remote controller on
the indoor unit is flashing.
Warm air blows from the indoor unit intermittently when heating mode is off
or during fan mode.
■
The indoor operation sound level is affected by the acoustics of the par-
ticular room as shown in the following table and will be higher than the
noise specification, which was measured in an echo-free room.
■
The batteries are low.
Replace the batteries and press the Reset button.
■
If nothing appears even after the batteries are replaced, make sure that
the batteries are installed in the correct directions (+, –).
■
The self diagnosis function has operated to protect the air conditioner.
■
Do not attempt to repair this equipment by yourself.
Turn off the power switch immediately and consult your dealer. Be sure
to provide the dealer with the model name.
■
When another indoor unit is operating in heating mode, the control valve
opens and closes occasionally to maintain stability in the air conditioning
system. This operation will stop after a while.
* If this will cause an undesirable rise in the room temperature in small
rooms, etc., stop the operation of the indoor unit temporarily.
High sound-
absorbing rooms
Broadcasting
studio, music
room, etc.
3 to 7 dB
Normal rooms
Reception room,
hotel lobby, etc.
6 to 10 dB
Low sound-
absorbing rooms
Office, hotel
room
9 to 13 dB
Location
examples
Noise levels
10. Trouble Shooting
Model
Power source
Capacity
Cooling <BTU/h>
Heating <BTU/h>
Dimension (Grille)
H
<inch>
W
<inch>
D
<inch>
Net weight (Grille)
<Ibs>
Fan Airflow range
DRY
<CFM>
(Low-Middle2-Middle1-High) WET
<CFM>
Noise level
<dB(A)>
(Low-Middle2-Middle1-High)
PLFY-P12NAMU-E PLFY-P15NAMU-E PLFY-P18NAMU-E PLFY-P24NAMU-E PLFY-P30NAMU-E PLFY-P36NAMU-E
Single 208/230 V 60 Hz
12,000
15,000
18,000
24,000
30,000
36,000
13,500
17,000
20,000
27,000
34,000
40,000
10-3/16(1-3/16)
11-3/4(1-3/16)
33-1/16(37-3/8)
33-1/16(37-3/8)
49(11)
49(11)
53(11)
53(11)
66(11)
66(11)
390-420-460-490
420-460-490-570
490-530-570-640
530-570-640-710
710-810-920-990
780-880-990-1060
350-380-410-440
380-410-470-530
380-500-530-600
500-530-600-670
670-770-870-930
730-830-930-1000
24-27-28-30
27-28-30-32
27-28-31-33
28-30-33-34
34-36-40-41
37-40-43-44
11. Specifications
■
PLFY Series
Model
Power source
Capacity
Cooling <BTU/h>
Heating <BTU/h>
Dimension (Grille)
H
<inch>
W
<inch>
D
<inch>
Net weight (Grille)
<Ibs>
Fan Airflow range
DRY
<CFM>
(Low-Middle-High)
WET
<CFM>
Noise level
<dB(A)>
(Low-Middle-High)
PLFY-P08NCMU-E PLFY-P12NCMU-E PLFY-P15NCMU-E
Single 208/230 V 60 Hz
8,000
12,000
15,000
9,000
13,500
17,000
8-3/16(13/16)
22-7/16(25-9/16)
22-7/16(25-9/16)
34(7)
37(7)
280-320-350
320-350-390
280-320-350
320-350-390
29-32-38
30-34-39
31-35-40
Model
Power source
Capacity
Cooling <BTU/h>
Heating <BTU/h>
Dimension
H
<inch>
W
<inch>
D
<inch>
Net weight
<Ibs>
Fan Airflow range
DRY
<CFM>
(Low-Middle2-Middle1-High) WET
<CFM>
Noise level
<dB(A)>
(Low-Middle2-Middle1-High)
PCFY-P15NGMU-E PCFY-P24NGMU-E PCFY-P30NGMU-E PCFY-P36NGMU-E
Single 208/230 V 60 Hz
15,000
24,000
30,000
36,000
17,000
27,000
34,000
40,000
8-1/4
11-1/16
39-7/16
51-9/16
63-3/4
26-3/4
60
75
82
95
280-350-390-420
420-490-570-640
640-710-810-880 920-990-1120-1230
250-310-350-380
380-470-530-600
600-670-770-830 870-930-1050-1160
29-33-36-38
32-34-37-39
36-38-41-43
37-39-42-44
■
PCFY Series