10. Cleaning the Indoor Unit Heat Exchanger
When dust adheres to the heat exchanger after the unit has been used for a long time, reducing the efficiency of heat exchange, and resulting in deterioration of cooling
performance.
Please ask your dealer how to arrange the clean.
11. When the Unit is to be Out of Use for a Long Time
<When the Unit is to be Out of Use for a Long Time>
(1) Run the unit in Fan mode for a period of 4 - 5 hours to dry the indoor unit.
(2) Turn the indoor unit power OFF.
<Preparations for Reuse>
X
Check the following (1) - (4), then turn the power supply on.
(1) Clean and fit the filter.
(2) Check that the inlets and outlets on the indoor and outdoor units are not
blocked.
(3) Check that the earth wire is connected. The earth wire may be connected
with the indoor unit as well in some cases.
Caution:
Do not connect the earth wire to gas pipes, water pipes, lightning rods, or
telephone earth wires. If earthing work is not conducted carefully it may
result in electric shock, smoke, flame, or mis-operation due to electrical
noise. Please ask your dealer before beginning earthing work.
(4) Check the drain hose to make sure there are not problems such as a bend,
raised end, or blockage.
(5) Turn the power supply on before 12 hours or more.
12. Specifications
<PFAV-P·VM-E series>
<Cooling>
<Heating>
Notes: *1 Cooling/Heating capacity indicates the rated value at operation under the following condition.
Cooling: Indoor: 27 °C DB/19 °C WB
Outdoor: 35 °C DB
Heating: Indoor: 20 °C DB
Outdoor: 7 °C DB/6 °C WB
*2 The operating noise is the data that was obtained in an anechoic room.
<PFAV-P·VM-E-F series>
<Cooling>
<Heating>
Notes: *1 Cooling/Heating capacity indicates the rated value at operation under the following condition.
Cooling: Indoor/Outdoor: 33 °C DB/28 °C WB
Heating: Indoor/Outdoor: 7 °C DB/3 °C WB
*2 The operating noise is the data that was obtained in an anechoic room.
*3 If the indoor unit intake air is pretreated so that its dry bulb temperature is 0 °C or above, the unit can be operated when the outdoor unit intake wet bulb
temperature is between –20 °C and 15.5 °C.
Model
Item
PFAV-P250VM-E
PFAV-P500VM-E
PFAV-P750VM-E
Power source
3N~/380V/400V/415V 50Hz/60Hz
Cooling capacity*1
kW
25.0
50.0
71.0
Heating capacity*1
kW
28.0
56.0
80.0
Dimension
Height
mm
1,748
1,899
1,860
Width
mm
1,200
1,420
1,750
Depth
mm
485
635
1,064
Net weight
kg
156
265
459
Fan Airflow rate (Low-Middle-High)
m³/min
90
180
260
Noise level*2
dB(A)
55
59/62
65
Indoor
Outdoor
Dry bulb temperature
–
-5 °C ~ 43 °C
Wet bulb temperature
10 °C ~ 25 °C
–
Indoor
Outdoor
Dry bulb temperature
15 °C ~ 28 °C
–
Wet bulb temperature
–
-20 °C ~ 15.5 °C
Model
Item
PFAV-P300VM-E-F
PFAV-P600VM-E-F
PFAV-P900VM-E-F
Power source
3N~/380V/400V/415V 50Hz/60Hz
Cooling capacity*1
kW
28.0
56.0
80.0
Heating capacity*1
kW
26.5
50.0
71.0
Dimension
Height
mm
1,748
1,899
1,860
Width
mm
1,200
1,420
1,750
Depth
mm
485
635
1,064
Net weight
kg
151
248
437
Fan Airflow rate (Low-Middle-High)
m³/min
45
90
120
Noise level*2
dB(A)
48.5
50
57
Indoor / Outdoor
Dry bulb temperature
20 °C ~ 43 °C
Wet bulb temperature
15 °C ~ 35 °C
Indoor / Outdoor
Dry bulb temperature
0 °C ~ 20 °C
Wet bulb temperature
–4 °C ~ 15.5 °C *3