17
7. Other Functions
7.5.2. Setting the energy-saving operation schedule
1) Bring up the "Energy saving" screen.
Move the cursor to the "Schedule," and press the
SELECT
button.
F1
F2
F3
F4
Energy saving
Setting display:
Cursor
Auto return Yes
Cool: min,
Heat: min,
Schedule No
Mon Tue Wed Thu Fri Sat Sun
2) The screen to see the schedule will appear.
Press the
F1
or
F2
button to see the settings for each day of the
week.
Press the
SELECT
button to go to the setting screen.
F1
F2
F3
F4
Energy saving
-
-
-
-
Setting display:
day
Mon
Tue Wed Thu Fri Sat Sun
No.
3) The screen to enable (Yes)/disable (No) the energy-saving
operation schedule will appear.
Select "No" or "Yes" with the
F3
or
F4
button.
Press the
SELECT
button to go to the setting change/day of the
week selection screen.
F1
F2
F3
F4
Energy saving
Select:
Cursor
Energy saving No /
Yes
4) The setting change/day of the week selection screen will appear.
Up to four operation patterns can be set for each day.
Move the cursor to the desired day of the week with the
F1
or
F2
button, and press the
F3
button to select it. (Multiple days
can be selected.)
Press the
SELECT
button to go to the pattern setting screen.
F1
F2
F3
F4
Energy saving
-
-
-
-
Input:
day
Select
Mon Tue Wed Thu Fri Sat Sun
No.
5) The pattern setting screen will appear.
Press the
F1
button to move the cursor to the desired pattern
number.
Move the cursor to the desired item with the
F2
button out of the
start time, stop time, and energy-saving rate (arranged in this order
from the left).
Change the settings with the
F3
or
F4
button.
• Start/Stop time: settable in 5-minute increments
* Press and hold the button to rapidly advance the numbers.
• Energy-saving rate: The setting range is 0% and 50 to 90% in 10%
increments.
Press the
SELECT
button to save the settings.
A confirmation screen will appear.
F1
F2
F3
F4
Energy saving
Energy saving
-
-
-
-
Select:
Cursor
Content
Day selection:
Mon
Mon
Changes saved
No.
The lower the value, the greater the energy-saving effect.
will appear on the Main display in the Full mode when the unit is operated
in the energy saving mode.
Cool
Room
Auto
Set temp.
Mode
Temp.
Fan
Fri
Navigating through the screens
• To go back to the setting change/day of the week
selection screen ...................................
SELECT
button
• To go back to the Main menu
...............
MENU
button
• To return to the previous screen
...........
RETURN
button
7.6. Night setback
<Function description>
This control starts heating operation when the control object group is
stopped and the room temperature drops below the preset lower limit
temperature. Also, this control starts cooling operation when the control
object group is stopped and the room temperature rises above the preset
upper limit temperature.
The Night setback function is not available if the operation and the
temperature setting are performed from the remote controller.
If the room temperature is measured by the air-conditioner's suction
temperature sensor, the accurate temperature may not be obtained when
the air-conditioner is inactive or when the air is not clean. In this case,
switch the sensor to a remote sensor (PAC-SE40TSA/PAC-SE41TS-E)
or a remote control sensor.