4) Louver setting (The factory setting is “01”.)
1. Press the
button
9
.
• The louver
G
blinks.
2. Press the button
4
to select the setting
number
D
.
Louver setting
G
Setting No.
D
No display (Disabled)
01
(Enabled)
02
• To enable (02) the louver function, disable (01)
the horizontal airflow direction function.
* If the setting is incorrect, press the
but-
ton
6
and repeat the procedure from step 1.
5) Auto fan speed and airflow direction setting (The
factory setting is "02".)
1. Press the
button
0
.
• The auto fan speed and airflow direction
H
blink. (2 locations)
2. Press the button
4
to select the setting
number
D
.
Auto fan speed and airfl ow
direction setting
H
Setting No.
D
No display (Disabled)
01
(Enabled)
02
* If the setting is incorrect, press the
but-
ton
6
and repeat the procedure from step 1.
6) Set temperature range setting (The factory setting
is“01”.)
1. Press the
button
1
• The number for the set temperature range
setting
J
“01” blinks.
2. Press the button
4
to change the setting
number
D
.
Set temperature
range setting
J
Setting
number
D
(Standard)
Cooling/Dry: 19 - 30 °C (67 - 87 °F)
Heating: 17 - 28 °C (63 - 83 °F)
Auto: 19 - 28 °C (67 - 83 °F)
01
Cooling/Dry: 14 - 30 °C (57 - 87 °F)
Heating: 17 - 28 °C (63 - 83 °F)
Auto: 17 - 28 °C (63 - 83 °F)
04
Notes:
• If the setting is incorrect, press the
but-
ton
6
and repeat the procedure from step 1.
• Single set point (Auto mode) must be selected
to enable the setting “04”. Refer to 7.3. for the
unit function selection and 5.4. for the way to
change the mode by the remote controller.
• The set temperature range of “04” cannot be
selected if the model does not support it.
6.4. Completing the settings
(Fig. 6-3)
Press the
button
3
for 5 seconds.
• The remote controller exits the function setting
mode.
Fig. 6-3
6
3
1
9
4
0
D
J
G
H
9
6. Function settings
en
VH79A034H01_IB_IM_01en.indd 9
2021/06/01 13:13:02
027