37
7. Main remote controller operation
<Continued from the previous page.>
<Main remote controller Menu Tree>
Unrestricted access
Installer only
Shaded items relate
to DHW functions.
These are only avail-
able if the system in-
cludes a DHW tank.
Long press
Main screen
Initial
Main
menu
Service
Password
protected
Manual operation
Function settings
Thermistor adjustment
Economy settings for pump
Electric heater (Heating)
Electric heater (DHW)
Mixing valve control
Flow sensor
Standard (Heat pump & electric heater)/Heater (Electric heater only)/
Boiler/Hybrid (Heat pump & heater/Boiler)
Freeze stat function
Simultaneous operation
Cold weather function
Boiler settings *1
Energy monitor
settings
External input settings
Running information
Thermistor reading
Summary of settings
Error history
Password protection
Manual reset
SD card *2
Heating
operation
H/P thermo diff.adjust
Flow temp.range
Room temp.control
Auxiliary settings
Heat source setting
Pump speed
Operation settings
ON/OFF
Delay
ON/OFF
Delay
Running
Interval
Flow t.
Outdoor ambient temp.
ON/OFF
Outdoor ambient temp.
ON/OFF
Hybrid
settings
Outdoor ambient temp.
Energy
price
CO
2
emission
Heat source
Schedule
Electricity
Electricity
Heat pump capacity
ON/OFF
Electric heater
capacity
Demand control (IN4)
Main remote controller
SD
Yes/No
Select download data
OFF (Heat source)/Boiler
Heater/Boiler
Outdoor thermostat (IN5)
FTC
Main RC
SD
Yes/No
Select upload data
Water pump input
Electric energy meter
Booster heater 1
Pump 1
Booster heater 2
Pump 2
Immersion heater
Pump 3
Boiler
Boiler
Boiler efficiency
Target temp.
Start & Finish
Temp. increase step
Temp. decrease step
Max. temp.
Max. temp. period
Increase interval
Decrease interval
Booster heater 2
capacity
Booster heater 1
capacity
Flow temp.
(Increase)
Flow temp.
(Decrease)
Priority
Ambient/
Cost /CO
2
Outdoor ambient temp.
Intelligent
settings
Min.temp.
ON/OFF
Mode
Interval
Max.temp.
Lower limit
Upper limit
Minimum
Maximum
Delay
ON/OFF (Booster heater/Immersion heater)
*1 For more details, refer to the installation manual of PAC-TH011HT-E.
*2 The SD card setting for multiple outdoor units control should be done after turning the power supply of all FTC units (Master/ Slave) ON.
If “COMPLETE!” does not appear, it means the operation is not properly completed. Reset the whole system before re-try.
Floor dry up function
For more details,
refer to Page 45.
(
(
<See section>
F1
F2
F3
Menu
Delivered energy adjustment
Heat meter
Main RC