29
11
DIP SWITCH FUNCTIONS
DIP SWITCH
Functions
1
IMP
(IMPEDANCE)
75
Ω
/ HIGH
2
TRAP
ON / OFF
3
MEMORY
FIELD / FRAME
4
RESERVED
5
RESERVED
6
RESERVED
Set to "75
Ω
" in normal use.
Set to "HIGH" when making branch connection of a monitor or
other units to the VIDEO IN connector.
Set to "OFF" in normal use.
Set to "ON" when inputting a color signal.
ON
:
The trap circuit is active.
OFF :
The trap circuit is inactive.
FRAME
:
Set to "FRAME" position in normal use.
FIELD
:
Set to "FIELD" position to print an image with rapid
motion.
2
The image displayed on the monitor is usually a single frame
consisting of two fields.
Set to "OFF".
(These switches are not used.)
ON
OFF
DIP SW
DIP SW FUNCTION TABLE
NO.
1
2
3
4
5
6
FUNCTION
IMP
TRAP
MEMORY
RESERVED
SW-ON
75
Ω
ON
FIELD
SW-OFF
HIGH
OFF
FRAME