4. The smart way to use

Even minimal steps to care for your air conditioner can help make its use far
more effective in terms of air-conditioning effect, electricity charges, etc.

Set the right room temperature

In cooling operation, a temperature difference of about 5 

°

C [9 

°

F] between

indoors and outdoors is optimum.

If the room temperature is raised by 1 

°

C [2 

°

F] during air-cooling operation,

about 10 % electric power can be saved.

Excessive cooling is bad for health. It also results in the waste of electric power.

Clean the filter thoroughly

If the screen of the air filter becomes clogged, the airflow and air-conditioning
effect can be significantly reduced.
Further, if the condition is left unattended, failure can result. It is particularly
important to clean the filter at the beginning of the cooling and heating sea-
sons. (When profuse dust and dirt have accumulated, clean the filter thoroughly.)

Prevent intrusion of heat during air-cooling

To prevent the intrusion of heat during cooling operation, provide a curtain or a
blind on the window to block out direct sunlight. Also, do not open the entrance
or exit except in cases of dire necessity.

Carry out ventilation sometimes

Since the air periodically gets dirty in a room that is kept closed for a long time,
ventilation is sometimes necessary. When gas appliances are used together
with the air conditioner, special precautions must be taken. If the “LOSSNAY”
ventilation unit developed by our company is used, you can perform ventilation
with less waste. For details on this unit, consult with your dealer.

5. Caring for the machine

Always have filter maintenance performed by a service person.
Before care-taking, turn the power supply OFF.

 Caution:

Before you start cleaning, stop operation and turn OFF the power supply.
Remember that the fan is rotating inside at high speed, posing a serious
risk of injury.

Indoor units are equipped with filters to remove the dust of sucked-in air.
Clean the filters using the methods shown in the following sketches. (The
standard filter should normally be cleaned once a week, and the long-life
filter at the beginning of each season.)

The life of the filter depends on where the unit is installed and how it is
operated.

How to clean

Clear dust away lightly or clean it up with a vacuum cleaner. In the case of
severe staining, wash the filter in lukewarm water mixed with dissolved neutral
detergent or water, and then rinse off the detergent completely. After washing,
dry it and fix it back into place.

 Caution:

Do not dry the filter by exposing it to direct sunlight or warming it using
fire, etc. Doing so can result in the deformation of the filter.

Washing it in hot water (more than 50 

°

C [122 

°

F]) can also result in defor-

mation.

 Caution:

Never pour water or flammable sprays onto the air conditioner. Cleaning using
these methods can result in the failure of the air conditioner, electric shock,
or fire.

KB79K384H01_en.p65

08.1.22, 6:02 PM

7

Summary of Contents for P08

Page 1: ...fe and correct use please read this operation manual thoroughly before operating the air conditioner unit MANUEL D UTILISATION Pour une utilisation correcte sans risques veuillez lire le manuel d utilisation en entier avant de vous servir du climatiseur F KB79K384H01_h1_h4 p65 08 1 30 5 23 PM 3 ...

Page 2: ...un Essai de fonctionnement A Touche Filter Filtre B Touche ON OFF Marche arrêt Touche C Position du capteur de température de la pièce intégré D Touche de réglage de l heure Ne jamais laisser la commande à distance en plein soleil sinon les données de température ambiante risquent d être erronées Ne jamais placer d obstacle devant la partie inférieure droite de la commande à distance sinon la lect...

Page 3: ...3 Fig A PEFY P NMSU E A A Filter Filtre Air Flow Flux d air KB79K384H01_illust p65 08 1 22 6 07 PM 3 ...

Page 4: ...led in a location where air and noise emit ted by the unit will not disturb the neighbours 2 Indoor unit Warning The indoor unit should be securely installed If the unit is loosely mounted it may fall causing injury 3 Remote controller Warning The remote controller should be installed in such a way that children cannot play with it 4 Drain hose Caution Make sure that the drain hose is installed so...

Page 5: ...o the atmosphere also damages the environment 2 Names and functions of various parts Attachment and detachment of filter Fig A P 3 3 How to operate Before starting operation Start running after the PLEASE WAIT display has disappeared The PLEASE WAIT display briefly appears on the room temperature display max 3 min utes when the power is turned on and after a power failure This does not indicate an...

Page 6: ...heat generated by the electric heater etc The fan speed comes to low or high 3 3 Room temperature adjustment To change room temperature Press the 1 Set Temperature Button and set the room temperature of your choice Pressing or once changes the setting by 1 C 1 F If the pressing is continued the setting continues to change by 1 C 2 F Indoor temperature can be set within the following range Cooling ...

Page 7: ...with the air conditioner special precautions must be taken If the LOSSNAY ventilation unit developed by our company is used you can perform ventilation with less waste For details on this unit consult with your dealer 5 Caring for the machine Always have filter maintenance performed by a service person Before care taking turn the power supply OFF Caution Before you start cleaning stop operation an...

Page 8: ... outdoor units The filter is filled with dust and dirt When other indoor units are engaged in cooling opera tion the machine stops after running a drain up mecha nism for 3 minutes when air cooling operation is stopped When other indoor units are engaged in cooling opera tion drained water is brought in If the drain water is collected the drain up mechanism initiates a draining operation When othe...

Page 9: ...reinstalling the air conditioner consult with your dealer Defective installation can result in electric shock fire etc Regarding noise In installing work choose a place that can fully bear the weight of the air con ditioner and where noise and vibration can be reduced Choose a place where cool or warm air and noise from the outdoor air outlet of the air conditioner does not inconvenience the neigh...

Page 10: ... enfants en bas âge ou à des handicapés sans supervision Toujours prendre toutes les précautions nécessaires pour éviter que des enfants en bas âge jouent avec cet appareil N utilisez pas d additif de détection des fuites 1 Appareil extérieur Avertissement L appareil extérieur doit être installé sur une surface plane et stable dans un endroit non sujet à l accumulation de neige de feuilles ou de d...

Page 11: ...nt du climatiseur aé rer convenablement la pièce et prendre contact avec le revendeur S il n est pas remédié à la situation des accidents risquent de se produire suite à un manque d oxygène Lorsque le climatiseur ne doit pas être utilisé pendant une certaine période Si le climatiseur ne doit pas être utilisé pendant une certaine période à cause d un changement de climat etc le faire fonctionner pe...

Page 12: ...a touche 8 Ventilation pour modifier la vitesse du ventilateur Selon les modèles le ventilateur de l appareil intérieur démarre lorsque l ap pareil est en mode de ventilation 3 1 ON OFF marche arrêt Pour mettre l appareil en fonctionnement 1 Appuyer sur la touche B ON OFF Le P témoin de fonctionnement s allume et l appareil se met en marche Pour arrêter le fonctionnement 1 Réappuyer sur la touche ...

Page 13: ...tes chaleurs risquent de le déformer Le lavage du filtre dans de l eau chaude dont la température est supé rieure à 50 C 122 F peut également provoquer une certaine déformation de celui ci Précaution Ne jamais verser de l eau ou vaporiser des produits inflammables dans le climatiseur car cela pourrait provoquer des pannes un danger d électrocu tion voire un incendie 4 Comment utiliser le climatise...

Page 14: ...pas Aucun affichage n appa raît même quand on ap puie sur la touche ON OFF L affichage à cristaux li quides indique que l ap pareil est en cours de fonctionnement L affichage à cristaux li quides indique que l ap pareil est en cours de fonctionnement Le code et la mention de vérification check cli gnotent sur l affichage à cristaux liquides Tous les témoins sont éteints sauf le témoin de mise sous...

Page 15: ...quis pour le déménage ment de l installation Précaution Lors du déménagement et de la réinstallation du climatiseur veuillez pren dre contact avec votre revendeur car une installation défectueuse peut être la cause d électrocution d incendie etc Faire également attention au bruit Lors des travaux d installation choisir un endroit capable de supporter entière ment le poids du climatiseur et où le b...

Page 16: ...00 8310 JAPAN Please be sure to put the contact address telephone number on this manual before handing it to the customer This product is designed and intended for use in the residential commer cial and light industrial environment KB79K384H01_h1_h4 p65 08 1 24 9 57 AM 2 ...

Reviews: