1 - 2 .   S P E C I F I C A T I O N S

1 - 1 .   T H E   F O L L O W

I N G   S H O U L D   A L W A Y S   B E   O B S E R V E D   F O R   S A F E T Y

•  Be sure to read “THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY” before installing the air conditioner.

•  Be sure to observe the  arnings and cautions specified here as they include important items related to safety.

•  After reading this manual, be sure to keep it together w ith the OPERATING INSTRUCTIONS for future reference.

R e q u i re d   T o o l s   fo r  I n s t a l l a t i o n

Phillips scre driver

Level

Scale
Utility knife or scissors
Torque w rench
Wrench (or spanner)

5/32 in. (4 mm) hexagonal 
w rench
Flare tool for R410A
Gauge manifold for R410A
Vacuum pump for R410A
Charge hose for R410A
Pipe cutter w ith reamer

 ENGLISH

C O N T E N T S

1.  BEFORE INSTALLATION ............................................................ 1
2.  OUTDOOR UNIT INSTALLATION ............................................... 3
3.  FLARING WORK AND PIPE CONNECTION ............................... 5
4.  PURGING PROCEDURES, LEAK TEST, AND TEST RUN ......... 6
5.  PUMPING  DOWN ........................................................................ 7

Model

Pow er supply

Pipe length and height difference *1, *2, *3, *4, *5, *6, *8, *9

Rated Voltage

Frequency

Max. pipe length per indoor unit / 

for multi-system

Max. height 

difference

Max. no. of bends per indoor unit / 

for multi system

Refrigerant 

adjustment A *7

MXZ-2C20NAHZ3

208 / 230 V

60 Hz

82 ft. (25 m) / 164 ft. (50 m)

49 ft. (15 m)

25 / 50

1.08 oz each 5 ft. 

(20 g/m)

MXZ-3C24NAHZ3
MXZ-3C30NAHZ3

82 ft. (25 m) / 230 ft. (70 m)

25 / 70

MXZ-5C42NA3

82 ft. (25 m) / 262 ft. (80 m)

25 / 80

*1 Never use pipes  ith thic ness less than specified. The pressure resistance 

ill be insufficient.

*2 Use a copper pipe or a copper-alloy seamless pipe.
*3 Be careful not to crush or bend the pipe during pipe bending.
*4 Refrigerant pipe bending radius must be 4 in. (100 mm) or more.

*5 Insulation material : Heat resisting foam plastic 0.045 specific gravity

*6 Be sure to use the insulation of specified thic ness. Excessive thic ness may 

cause incorrect installation of the indoor unit and insufficient thic ness may 

cause dew  drippage.

*7 If pipe length exceeds 98 ft. (30 m), additional refrigerant (R410A) charge is 

required. (No additional charge is required for pipe length less than 98 ft. (30 m).)

  D o   n o t   i n s t a l l   t h e   u n i t   b y   y o u rs e l f  ( u s e r) .

  Incomplete installation could cause fire or electric shoc , injury due to the unit 

falling, or leakage of w ater. Consult the dealer from w hom you purchased the 

unit or a qualified installer.

  F o l l o w   t h e   i n s t ru c t i o n s   d e t a i l e d   i n   t h e   i n s t a l l a t i o n   m a n u a l .

  Incomplete installation could cause fire or electric shoc , injury due to the unit 

falling, or leakage of w ater. 

  W

h e n   i n s t a l l i n g   t h e   u n i t ,   u s e   a p p ro p ri a t e   p ro t e c t i v e   e q u i p m e n t   a n d   t o o l s  

fo r  s a fe t y .

 

Failure to do so could cause injury.

  I n s t a l l   t h e   u n i t   s e c u re l y   i n   a   p l a c e   t h a t   c a n   b e a r  t h e   w e i g h t   o f  t h e   u n i t .

 

If the installation location cannot bear the w eight of the unit, the unit could fall 
causing injury.

■ 

P e rfo rm   e l e c t ri c a l   w o rk   a c c o rd i n g   t o   t h e   i n s t a l l a t i o n   m a n u a l   a n d   b e   s u re  
t o   u s e   a n   e x c l u s i v e   c i rc u i t .   D o   n o t   c o n n e c t   o t h e r  e l e c t ri c a l   a p p l i a n c e s   t o  
t h e   c i rc u i t .

  If the capacity of the po er circuit is insufficient or there is incomplete electrical 

or , it could result in a fire or an electric shoc .

  G ro u n d   t h e   u n i t   c o rre c t l y .

 

Do not connect the ground w ire to a gas pipe, w ater pipe, lightning rod or 

telephone ground. Defective grounding could cause electric shoc .

■ 

D o   n o t   d a m a g e   t h e   w i re s .

  Damaged  ires could cause fire.

■ 

B e   s u re   t o   s h u t   o ff  t h e   m a i n   p o w e r  w h e n   s e t t i n g   u p   t h e   i n d o o r  P . C .   b o a rd  
o r  w i ri n g .

 

Failure to do so could cause electric shock.

  Use the specified  ires to securely connect the indoor and outdoor units. 

Attach the  ires firmly to avoid applying stress to the terminal bloc .

  Improper connection could cause fire.

■ 

Do not install the unit in a place  here flammable gas may lea .

 

If gas leaks and accumulates around the unit, it could cause an explosion.

  D o   n o t   u s e   i n t e rm e d i a t e   c o n n e c t i o n   o f  t h e   p o w e r  c o rd   o r  t h e   e x t e n s i o n  

c o rd . D o   n o t   c o n n e c t   m a n y   d e v i c e s   t o   o n e   A C   o u t l e t .

  It could cause a fire or an electric shoc .

■ 

Use the parts provided or specified parts for the installation  or .

  The use of defective parts could cause an injury or lea age of  ater due to a 

fire, an electric shoc , the unit falling, etc.

■ 

W

h e n   p l u g g i n g   t h e   p o w e r  s u p p l y   p l u g   i n t o   t h e   o u t l e t ,   m a k e   s u re   t h a t   t h e re  

i s   n o   d u s t ,   b l o c k a g e ,   o r  l o o s e   p a rt s   b o t h   i n   t h e   o u t l e t   a n d   o n   t h e   p l u g .  
V e ri fy   t h a t   t h e   p o w e r  s u p p l y   p l u g   i s   c o m p l e t e l y   i n   t h e   o u t l e t .  

 

If there is dust, blockage, or loose parts on the pow er supply plug or the outlet, 

it could cause electric shoc  or fire. If loose parts are found on the po er supply 

plug, replace it.

■ 

S e c u re l y   a t t a c h   t h e   e l e c t ri c a l   c o v e r  t o   t h e   i n d o o r  u n i t   a n d   t h e   s e rv i c e  
p a n e l   t o   t h e   o u t d o o r  u n i t .

  If the electrical cover of the indoor unit and/or the service panel of the outdoor 

unit are not attached securely, dust, w ater, etc. could collect in the unit and 

could cause a fire or an electric shoc .

■ 

W h e n   i n s t a l l i n g ,   re l o c a t i n g ,   o r  s e rv i c i n g   t h e   u n i t ,   m a k e   s u re   t h a t   n o   s u b s t a n c e  

other than the specified refrigerant (R410A) enters the refrigerant circuit.

 

Any presence of foreign substance such as air can cause abnormal pressure 
rise and may result in explosion or injury. The use of any refrigerant other than 

that specified for the system  ill cause mechanical failure, system malfunction, 

or unit breakdow n. In the w orst case, this could lead to a serious impediment 
to securing product safety.

■ 

D o   n o t   d i s c h a rg e   t h e   re fri g e ra n t   i n t o   t h e   a t m o s p h e re .   C h e c k   t h a t   t h e  
re fri g e ra n t   g a s   d o e s   n o t   l e a k   a ft e r  i n s t a l l a t i o n   h a s   b e e n   c o m p l e t e d .   I f 
re fri g e ra n t   l e a k s   d u ri n g   i n s t a l l a t i o n ,   v e n t i l a t e   t h e   ro o m .

  If refrigerant comes in contact  ith a fire, harmful gas could be generated. 

  If refrigerant gas lea s indoors, and comes into contact  ith the flame of a fan 

heater, space heater, stove, etc., harmful gases  ill be generated.

■ 

U s e   a p p ro p ri a t e   t o o l s   a n d   p i p i n g   m a t e ri a l s   fo r  i n s t a l l a t i o n .  

 

The pressure of R410A is 1.6 times higher than R22. Not using the appropri-
ate tools and materials, or improper installation could cause the pipes to burst 
causing an injury. 

■ 

W

h e n   p u m p i n g   d o w n   t h e   re fri g e ra n t ,   s t o p   t h e   c o m p re s s o r  b e fo re   d i s c o n -

n e c t i n g   t h e   re fri g e ra n t   p i p e s .

 

If the refrigerant pipes are disconnected w hile the compressor is running and 

the stop valve is open, air could be dra n in and the pressure in the refrigera

-

tion cycle could become abnormally high, causing the pipes to burst. 

■ 

W

h e n   i n s t a l l i n g   t h e   u n i t ,   s e c u re l y   c o n n e c t   t h e   re fri g e ra n t   p i p e s   b e fo re  

s t a rt i n g   t h e   c o m p re s s o r.

 

If the compressor is started before the refrigerant pipes are connected and the 

stop valve is open, air could be dra n in and the pressure in the refrigeration 

cycle could become abnormally high, causing the pipes to burst.

■ 

Fasten a flare nut  ith a torque  rench as specified in this manual.

  If fastened too tight, a flare nut could brea  and cause refrigerant lea age.

■ 

I n s t a l l   t h e   u n i t     a c c o rd i n g   t o   n a t i o n a l   w i ri n g   re g u l a t i o n s .

  B e   s u re   t o   i n s t a l l   a   G ro u n d   F a u l t   I n t e rru p t   ( G F I )   c i rc u i t   b re a k e r.

 

Failure to install a Ground Fault Interrupt (GFI) circuit breaker may result in 

electric shoc  or fire.

  W

h e n   o p e n i n g   o r  c l o s i n g   t h e   v a l v e   b e l o w   fre e zi n g   t e m p e ra t u re s ,   re fri g -

e ra n t   m a y   s p u rt   o u t   fro m   t h e   g a p   b e t w e e n   t h e   v a l v e   s t e m   a n d   t h e   v a l v e  
b o d y ,   re s u l t i n g   i n   i n j u ri e s .

  P e rfo rm   t h e   d ra i n a g e / p i p i n g   w o rk   s e c u re l y   a c c o rd i n g   t o   t h e   i n s t a l l a t i o n  

m a n u a l .

 

If there is defect in the drainage/piping w ork, w ater could drip from the unit, 
and damage household items.

  Do not touch the air inlet or the aluminum fins of the outdoor unit.

 

This could cause injury. 

  D o   n o t   i n s t a l l   t h e   o u t d o o r  u n i t   w h e re   s m a l l   a n i m a l s   m a y   l i v e .

 

If small animals enter the unit and damage its electrical parts, it could cause a 

malfunction, smo e emission, or fire.  eep the area around the unit clean. 

 CAUTION

(Could lead to serious injury w hen operated incorrectly.)

 WARNING

(Could lead to death or serious injury, etc.)

1 .   B E F O R E   I N S T A L L A T I O N

 

Additional refrigerant (ft.) = A × 

(pipe length (ft.) - 98)

5

 

Additional refrigerant (m) = A × (pipe length (m) - 30)

*8 The  piping  specification  table  does  not  provide  a  minimum  line  set  length. 

Ho ever, indoor units  ith connected piping length less than 10 ft. (3m) could 

produce intermittent noise during normal system operation in very quiet envi

-

ronments. Please be aw are of this important information w hen installing and 
locating the indoor unit w ithin the conditioned space.

*9  hen connecting t o PAA-A18 units, be sure to provide the total piping length 

of 33 ft (10 m) or more and change the gas pipe diameter to ø5/8 inch (15.88 
mm).

VG79N001H01_01En.indd   1

2021/07/13   12:24:05

Summary of Contents for MXZ-2C20NAHZ3

Page 1: ...eil intérieur consultez la notice d installation de cet appareil Toute altération structurelle requise pour l installation doit être conforme aux exi gences du code du bâtiment local M a n u a l d e i n s t a l a c i ó n Para el INSTALADOR En este manual só lo se describe la instalació n de la unidad exterior Para instalar la unidad interior consulte el manual de instalació n de dicha unidad Cualq...

Page 2: ... d o n t h e p l u g V e ri fy t h a t t h e p o w e r s u p p l y p l u g i s c o m p l e t e l y i n t h e o u t l e t If there is dust blockage or loose parts on the pow er supply plug or the outlet it could cause electric shoc or fire If loose parts are found on the po er supply plug replace it S e c u re l y a t t a c h t h e e l e c t ri c a l c o v e r t o t h e i n d o o r u n i t a n d t ...

Page 3: ...quired 2 F ro n t b l o w i n g s i d e o p e n As long as space indicated in the figure is provided it is allo ed to install the unit w here obstacles are behind and on the sides of the unit No obstacle above the unit F R E E S P A C E R E Q U I R E D A R O U N D O U T D O O R U N I T Service space When installing the unit in an area that is enclosed w ith w alls such as a verandah be sure to hav...

Page 4: ...re than 3 15 16 in 100 mm Open as a rule More than 19 11 16 in 500 mm if the front and both sides are open More than 3 15 16 in 100 mm More than 7 7 8 in 200 mm if there are obstacles to both sides Open as a rule More than 19 11 16 in 500 mm if the back both sides and top are open More than 13 25 32 in 350 mm O u t d o o r u n i t i n s t a l l a t i o n Air inlet Air outlet 2 U shape notched hole...

Page 5: ... l e c t ri c a l c o d e G R O U N D W I R E Use solid or stranded conductor Min AWG8 Use copper conductors only F o l l o w l o c a l e l e c t ri c a l c o d e W A R N I N G U s e t h e i n d o o r o u t d o o r u n i t c o n n e c t i n g w i re t h a t m e e t s t h e S t a n d ards to connect the indoor and outdoor units and fix the ire to t h e t e rm i n a l b l o c k s e c u re l y s o t ...

Page 6: ...ine for indoor unit side union joint section and tighten using t o renches Excessive tightening damages the flare section 1 Apply a thin coat of refrigeration oil G to the flared ends of the pipes and the pipe connections of the outdoor unit Do not apply refrigeration oil on screw threads Excessive tightening torque ill result in damage on the scre 2 or connection first align the center then tight...

Page 7: ...se coming from refrigerant gas cylinder 3 Replenish specified amount of the refrigerant hile operating the air conditioner for cooling N o t e In case of adding refrigerant comply ith the quantity specified for the refrigerating cycle C A U T I O N When charging the refrigerant system w ith additional refrigerant be sure to use liquid refrigerant Adding gas refrigerant may change the composition o...

Page 8: ...tioner W i ri n g p i p i n g c o rre c t i o n fu n c t i o n This unit has a w iring piping correction function w hich corrects w iring and piping combination When there is pos sibility of incorrect iring and piping combination and confirming the combination is difficult use this function to detect and correct the combination by follow ing the procedures below Make sure that the follow ing is do...

Page 9: ...r à fond la fiche d alimentation d a n s l a p ri s e s e c t e u r La présence de poussière de saleté ou d éléments desserrés sur la fiche d alimentation ou la prise secteur peut entraîner un choc électrique ou un incendie Remplacez les éventuels éléments desserrés F i x e z c o rre c t e m e n t l e c o u v e rc l e d u b o î t i e r é l e c t ri q u e d e l u n i t é i n t e rn e e t l e p a n ...

Page 10: ... le climatiseur alors que la température extérieure est basse veillez à observer les instructions ci dessous N installez jamais l unité externe dans un endroit où le côté présentant l entrée la sortie d air risque d être directement exposé au vent Pour protéger l unité externe du vent installez la de façon à ce que l entrée d air soit face au mur Pour éviter toute exposition au vent il est recomma...

Page 11: ... tuyauterie ou isoler la tuyauterie en lui appliquant 7 à 8 couches de ruban isolant en vinyle Pour utiliser la tuyauterie existante effectuer un cycle COOL REFROI DISSEMENT de 30 minutes et lancer l aspiration avant de procéder à la dépose de l ancien climatiseur Reformer l écrou évasé en respec tant les dimensions des nouveaux tuyaux de réfrigérant 23 5 8 600 14 9 16 370 Fixer ici avec des boulo...

Page 12: ... à a u c u n e c o n t ra i n t e e x t é ri e u re U n raccordement incomplet ou une fixation incorrecte risqueraient de p ro v o q u e r u n i n c e n d i e Raccorder les fils aux bornes associées aux numéros correspondants Lors du raccordement du cordon et ou du fil au bloc de sortie veiller à fixer chaque vis à la borne correspondante APPAREIL INTÉRIEUR Prévoir une longueur de câble de raccord...

Page 13: ...de passage de l appareil intérieur utiliser un joint de diamètre différent en option 2 Reportez vous au manuel d installation de la série P pour des détails sur les MVZ A et SVZ KP 3 Pour raccorder l appareil PAA A18 changez le diamètre du tuyau de gaz en ø5 8 pouce 15 88 mm Respecter les couples de serrage indiqués dans le tableau ci dessus pour raccorder la tuyauterie de l appareil intérieur et ...

Page 14: ...dant une minute ou deux Assurez vous que l aiguille de la vanne du collecteur à jauge reste dans la même position Véri fiez que le manomètre indique une pression de 14 7 psi Jauge 0 101 MPa 6 Retirez rapidement la vanne du collecteur à jauge de l ouverture de service du robinet d arrêt 7 Lorsque les tuyaux de réfrigérant sont raccordés et purgés ouvrez complè tement la tige de robinet de tous les ...

Page 15: ...nts de câblage et tuyauterie de manière conventionnelle en faisant fonctionner les appareils intérieurs l un après l autre Pour utiliser cette fonction l appareil doit être alimenté Veiller à ne pas toucher des éléments autres que le commutateur notamment le panneau de commande Cela peut entraîner un choc électrique ou des brûlures par des éléments chauds ou sous tension situés autour du commuta t...

Page 16: ...rt a d o e n l a t o m a Si hay polvo obstrucciones o piezas sueltas en el enchufe de alimentaci n o la toma podr a provocar incendios o descargas eléctricas Si el enchufe de alimentaci n presenta piezas sueltas sustit yalo Fije firmemente la cubierta de la instalaci n eléctrica a la unidad interior y e l p a n e l d e s e rv i c i o a l a u n i d a d e x t e ri o r Si no se fijan con firmeza la c...

Page 17: ... el acondicionador de aire cuando la temperatura exterior sea baja observe las instrucciones siguientes No instale nunca la unidad exterior en un lugar en el que el lado de entra da salida de aire quede expuesto directamente al viento Para evitar la exposició n al viento instale la unidad exterior con el lado de entrada de aire hacia la pared Para evitar la exposició n al viento se recomienda inst...

Page 18: ...tada qu micamente de 25 32 pulg 20 mm o m s de grosor entre la pared y los tubos o envuelva los tubos con u 8 vueltas de cinta aislante de vinilo Para utilizar tuber as ya existentes active el modo COOL REFRIGERA CI N durante 30 minutos y realice el bombeo de vaciado antes de retirar el acondicionador de aire antiguo Adapte el abocardado a las dimensiones para el nuevo refrigerante 2 1 I N S T A L...

Page 19: ... n a conexi n y fijaci n defectuosas podr an provocar un incendio C o n e c t e l o s c a b l e s a l n ú m e ro c o rre s p o n d i e n t e d e t e rm i n a l e s A s e g ú re s e d e c o n e c t a r c a d a t o rn i l l o c o n s u t e rm i n a l c o rre s p o n diente cuando fije los cables al panel de terminales Con vistas a un futuro mantenimiento prolongue los cables de conexi n 2 2 C A B L ...

Page 20: ...distintos diá metros opcionales 2 Consulte el manual de instalaci n de la serie P para conocer los detalles de MVZ A y SVZ KP 3 Para conectar la unidad PAA A18 cambie el di metro del tubo de gas a 5 8 pulg 15 88 mm Utilice la tabla de pares de torsi n anterior como gu a para la secci n de uni n lateral de la unidad interior y apriete empleando dos llaves Procure no apretar demasiado ya que podrí a...

Page 21: ... la vá lvula podrí a deformarse o soltarse si se aplica demasiada presió n Esto podrí a provocar fugas de gas Puerto de servicio Manguera de carga para R410A Cuerpo Cerrado Abierta Vá lvula de control A Al conectar la vá lvula de control al puerto de servicio aseg rese de que la pieza interior de la v lvula est cerrada y a continuaci n apriete la pieza A No apriete la piezaAni gire la pieza interi...

Page 22: ...cionar las unidades interiores una a una Mientras la operaci n se lleva a cabo la unidad recibe corriente Aseg rese de no tocar nada m s que el interruptor tampoco la placa de circuito impreso Podr a sufrir una descarga eléctrica o quemaduras de las partes que reciben corriente o que está n calientes en torno al interruptor Si toca las partes que reciben corriente puede dañ ar la placa de circuito...

Page 23: ...A4_white_tombo indd 1 2018 08 09 14 11 29 ...

Page 24: ...VG79N001H01 HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN VG79N001H01_cover4 indd 2 2021 02 10 14 22 22 ...

Reviews: