SPECIFICATION
10
4
1
1
1
Item
Model
Capacity
Power
consumption
EER [SEER]
HSPF IV (V)
COP
External finish
Power supply
Max. fuse size (time delay)
Min. circuit ampacity
Fan motor
Compressor
Refrigerant control
Sound level
Defrost method
Dimensions
Weight
Remote controller
Control voltage (by built-in transformer)
Refrigerant piping
Valve size
Connection method
Refrigerant charge (R410A)
Refrigeration oil (Model)
Model
Winding resistance (at 68˚F)
"
W
D
H
Liquid
Gas
Indoor
Outdoor
Btu/h
Btu/h
Btu/h
W
W
W
V, phase, Hz
A
A
F.L.A
R.L.A
L.R.A
dB(A)
in.
in.
in.
lb.
in.
in.
lb.
oz.
20,000/ (7,800 ~ 20,000)
22,000/ (8,500 ~ 22,000)
14,500
2,150/ (630 ~ 2,150)
1,780/ (520 ~ 1,780)
1,500 (1,500)
9.3 [15]
9.0 (7.0)
12.4
Munsell 5Y 8/1
208/230, 1, 60
20
15
0.96
U-V 0.45 V-W 0.45 W-U 0.45
U-V 0.98 V-W 0.98 W-U 0.98
10.1
15
LEV
49/51
Reverse cycle
33-1/16
13
27-15/16
130
Wireless type
12-24V DC
Not supplied (optional parts)
1/4
A,B:3/8
Flared
Flared
5lb. 15oz.
❈
1
❈
3
❈
1
❈
1
❈
2
❈
1
❈
1
❈
2
Cooling
Heating 47
Heating 17
Cooling
Heating 47
Heating 17
Cooling
Heating
Heating
MXZ-2A20NA MXZ-2A20NA -
SNB130FPDH1
SNB130FQBH1
20.3 (NEO22)
23.7 (NEO22)
MXZ-2A20NA
MXZ-2A20NA -
MXZ-2A20NA
MXZ-2A20NA -
1
MXZ-2A20NA
MXZ-2A20NA -
Cooling
Heating
Mode
❈
1: "A" Cooling Steady State at rated compressor Speed
❈
3: "B-2" Cooling Steady State at rated compressor Speed
"B-1" Cooling Steady State at minimum compressor Speed
Low ambient Cooling Steady State at minimum compressor Speed
Intermediate Cooling Steady State At Intermediate compressor Speed
w
❈
1: Standard Rating-Heating at rated compressor Speed
❈
2: Low temperature Heating at rated compressor Speed
Max. temperature Heating at minimum compressor Speed
High temperature Heating at minimum compressor Speed
Frost Accumulation at rated compressor Speed
Frost Accumulation at Intermediate compressor Speed
w
Test
Indoor air condition Outdoor air condition
Dry bulb Wet bulb Dry bulb
Wet bulb
80
80
80
80
80
70
70
70
70
70
70
67
67
67
67
67
60
60
60
60
60
60
95
82
82
67
87
47
17
62
47
35
35
(75)
(65)
(65)
(53.5)
(69)
43
15
56.5
43
33
33
w
At Intermediate compressor Speed
=("Cooling rated compressor speed" - "minimum compressor speed") / 3 + "minimum compressor speed".
Unit: ˚F
NOTE : Test conditions are based on ARI 210/240.
❈
1 : Rating conditions (cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 95˚FDB, (75˚FWB)
(heating) — Indoor : 70˚FDB, 60˚FWB, Outdoor : 47˚FDB, 43˚FWB
❈
2 :
(heating) — Indoor : 70˚FDB, 60˚FWB, Outdoor : 17˚FDB, 15˚FWB
❈
3 :
(cooling) — Indoor : 80˚FDB, 67˚FWB, Outdoor : 82˚FDB, 65˚FWB
OB444B--1.qxp 07.4.17 4:27 PM Page 10
Summary of Contents for MXZ-2A20NA-1
Page 15: ...15 WIRING DIAGRAM 6 MXZ 2A20NA OB444B 1 qxp 07 4 17 4 27 PM Page 15 ...
Page 16: ...16 MXZ 2A20NA 1 OB444B 1 qxp 07 4 17 4 28 PM Page 16 ...
Page 17: ...17 MXZ 3A30NA OB444B 1 qxp 07 4 17 4 28 PM Page 17 ...
Page 18: ...18 MXZ 3A30NA 1 OB444B 1 qxp 07 4 17 4 28 PM Page 18 ...