55
J Check of power supply
Is there voltage 230 V AC
between the indoor terminal
block S1 and S2?
No
Yes
Replace the indoor
electronic control P.C.
board.
Rectify indoor/outdoor
connecting wire.
Yes
If lights up, OK.
If blinks, refer to 12-3.
Does the upper lamp of
OPERATION INDICATOR lamp on
the indoor unit light up?
Does LED on the inverter P.C.
board light up or blink?
(Refer to 12-6.1.)
No
Replace the inverter
P.C. board.
Is there bus-bar voltage 260 - 370 V
DC between DB61 (+) and DB61 (–)
(
MUZ-AP25/35/42/50/60VG, MUZ-
AP25/35/42/50VGH
)/325 - 370 V
DC between IC700 (P) and (N)
(
MUZ-AP71VG
) on the inverter P.C.
board? (Refer to 12-6.1.)
No
Check the electric parts in main circuit.
Yes
Yes
No
Disconnect the connector between the
compressor and the power module
(IC700). Turn ON power supply and
press EMERGENCY OPERATION
switch.
Inverter P.C. board
(Solder side)
DB61
260 - 370 V DC
IC700
N
P
MUZ-AP25/35/42/50/60VG
MUZ-AP25/35/42/50VGH
325 -370 V DC
MUZ-AP71VG
OBH789A
Summary of Contents for MUZ-AP25VG
Page 12: ...12 Unit mm MUZ AP50VG MUZ AP60VG MUZ AP50VGH MUZ AP50VG H MUZ AP60VG OBH789A ...
Page 15: ...15 MUZ AP42VG E1 ET1 E2 ET2 ER2 MUZ AP42VGH E1 E2 OBH789A ...
Page 16: ...16 MUZ AP50VG E1 ET1 MUZ AP50VGH E1 OBH789A ...
Page 17: ...17 MUZ AP60VG E1 ET1 MUZ AP71VG E1 ET1 OBH789A ...
Page 76: ......