25
OPERATING PROCEDURE
PHOTOS
5. Removing the compressor
(1) Remove the cabinet. (Refer to 1.)
(2) Remove the relay panel.
(3) Remove the soundproof felt.
(4) Remove the terminal cover on the compressor.
(5) Disconnect lead wires from the glass terminal of the
compressor.
(6) Recover gas from the refrigerant circuit.
NOTE:
Recover gas from the pipes until the pressure
gauge shows 0 kg/cm
2
(0 MPa).
(7) Disconnect the welded part of the discharge pipe.
(8) Disconnect the welded part of the suction pipe.
(9) Remove nuts fixing the compressor.
(10) Remove the compressor.
Photo 7 <MU-GE50VB>
Photo 8 <MUH-GE50VB>
Compressor
Suction pipe
Discharge pipe
Glass terminal
4-Way valve
Discharge pipe
Compressor nuts
Glass terminal
Suction pipe