19
9-2.
MU-A10ND
OUTDOOR UNIT
OPERATING PROCEDURE
PHOTOS
1. Removing the cabinet
(1) Remove the screws fixing the top panel.
(2) Remove the top panel.
(3) Remove the screw fixing the service panel.
(4) Pull down the service panel and remove it.
(5) Remove the screws fixing the cabinet.
(6) Remove the cabinet.
(7) Disconnect the indoor/ outdoor connecting wire.
(8) Remove the screws fixing the back panel.
(9) Remove the back panel.
Photo 1
Photo 3
Screws of
the top panel
Screws of
the cabinet
Screws of the cabinet
Photo 2
Screws of the front panel and motor support
Screws of the
top panel
Service
panel
Screw of the
cabinet
Direction
to remove
Hooks
Screw of the
service panel
2. Removing the electrical parts
(1) Remove the service panel and the cabinet. (Refer to 1.)
(2) Remove the following parts.
•Compressor capacitor (C1)
•Outdoor fan capacitor (C2)
•Terminal block (TB)
Photo 4
Outdoor fan capacitor (C2)
Compressor capacitor (C1)
Terminal block (TB)
Photo : MU-A10ND -
C1
OB403B--1.qxp 07.6.26 11:30 AM Page 19