11-2. MUZ-WR24NA
NOTE:
Turn OFF the power supply before disassembly.
OPERATING PROCEDURE
PHOTOS/FIGURES
1. Removing the cabinet
(1) Remove all the screws of the service panel.
(2) Remove all the screws of the top panel.
(3) Remove the screw of the valve cover.
(4) Remove the service panel.
(5) Remove all the screws fixing the conduit cover.
(6) Remove the conduit cover.
(7) Remove the screw of fixing the conduit plate.
(8) Remove the conduit plate.
(9) Remove the top panel.
(10) Remove the valve cover.
(11) Disconnect the power supply and indoor/outdoor connect-
ing wire.
(12) Remove all the screws of the cabinet.
(13) Remove the cabinet.
(14) Remove all the screws of the back panel.
(15) Remove the back panel.
Photo 3
Photo 4
Photo 1
Photo 2
54
Screws of the cabinet
Screws of the top panel
Screws of the top panel
Screw of the back panel
Screws of the cabinet
Screws of
the cabinet
Screws of the service panel
Screw of
the valve
cover
Screws of
the cabinet
Screws of
the back panel
Screws
of the
cabinet
Screws of the conduit cover
Screw of the conduit plate
OBH819A
Summary of Contents for MSZ-WR NA Series
Page 9: ...9 5 WIRING DIAGRAM MUZ WR09NA MUZ WR12NA MUZ WR18NA OBH819A ...
Page 10: ...10 MUZ WR24NA OBH819A ...
Page 57: ...57 OBH819A ...