•  Connect wires to the appropriate terminals
•  For future servicing, leave some slack in the connecting wires.

•  Make ground wire a little longer than 

others. (More than 1-9/16 in. [40 mm])

2-1. ATTACHING THE INSTALLATION PLATE 

•  Find a stud in the wall to attach installation plate (1) horizontally on the wall with screws (2).
•  To prevent installation plate (1) from vibrating, be sure to install the attachment screws in 

the holes indicated in the illustration. For added support, additional screws may also be 
installed in other holes.

•  When the indoor unit is to be attached to a concrete wall using recessed bolts, secure 

installation plate (1) using 7/16 in. x 13/16 in. · 7/16 in. x 1 in. (11 mm × 20 mm · 11 mm 
× 26 mm) oval hole (17-3/4 in. [450 mm] pitch).

•  If the recessed bolt is too long, change it for a shorter one (field-supplied).

2.  INDOOR UNIT INSTALLATION

Wall

Outdoor side

2-2. DRILLING

1) Determine where the holes will be located on the wall.
2) Drill a ø 3 in. (75 mm) hole. The outdoor side should be 6/32 to 9/32 in. (5 to 7 mm) 

lower than the indoor side.

3) Insert wall hole sleeve (C).

2-3. CONNECTING WIRES FOR INDOOR UNIT

Note:

When the indoor unit is powered from the outdoor unit, depending on local code, a discon-
nect switch needs to be installed to a power supply circuit.

1) Remove the panel assembly. (Refer to 5-1.)
2) Place the upper part of the indoor unit on the installation plate.
3) Remove corner box and electrical cover.
4) Remove display panel, conduit cover and conduit plate.
5) Attach conduit pipe (for rear piping) / elbow joint (for right, left, or downward piping) to 

conduit plate with lock nut. The thread of the installed conduit pipe / elbow joint appear-
ing inside should be less than 3/8 in. (10 mm). (Fig. 1) Elbow joint should appear less 
than 1-3/16 in. (30 mm) outside. (Fig. 2)

6) Process the end of ground wire (Fig. 3). Connect it to the ground terminal of electrical 

parts box.

7) Process the end of indoor/outdoor unit connecting wire (A) (Fig. 3). Attach it to the 

terminal block. Be careful not to make mis-wiring. Attach the wire to the terminal block 
securely so that its core cannot be seen, and no external force affects the connecting 
section of the terminal block.

8) Firmly tighten the terminal screws. After tightening, verify that the wires are tightly fas-

tened.

9) Reinstall conduit plate, conduit cover and display panel.
10) According to the piping direction, remove the shaded part of the left side of box (Fig. 4) 

or corner box (Fig. 5). Reinstall electrical cover, corner box and front panel. 

Less than 3/8 in.
(10 mm)

Conduit plate

Conduit pipe or 
elbow joint

Lock nut

6/32-9/32 in.
(5-7 mm)

Ø 3 in.
   (75 mm)

Lead 
wire

19/32 in.
(15 mm)

1-3/8 in.
(35 mm)

Indoor terminal 

block

Fixing 
screw

Conduit cover

Lock nut

Conduit plate

Elbow joint
(for right, left, or downward piping)

Elbow joint

(for right, left, or downward piping)

Less than 1-3/16 in.  
(30 mm)

Corner box

Remove panel for piping 
on right side of unit

Remove panel for 
piping on bottom side 
of unit

Fig. 1

Fig. 2

Fig. 3

Fig. 4

Fig. 5

Box

Remove panel for 
piping on left side of 
unit

Remove panel for 
piping on bottom left 
side of unit

Level 

Installation plate (1)

Plumb

Align the plumb 
line with the 
mark 

Center of  
ø 3 in.  
(75 mm) hole

4-3/8 in. 
(110 mm) 
or more 

3-7/8 in. 
(100 mm) 
or more 

Bind the line to the center hole.

2-1/8 in. (54 mm) or more

5-1/8 in. (130 mm) or more for left 
and left back piping (using spacer)

Ceiling

Wall

Attachment screw (2)

* Same for left hole.

Insert 

the 
scale. *

Align the 

scale with 
the line. *

5-1/8 in.(130 mm)

INDOOR UNIT

Terminal block

208/230 V AC 
1phase, 60 Hz

Grounding 
terminal**

Disconnect 
switch*

OUTDOOR UNIT

Grounding terminal**

Ground

Power supply 
208/230 V AC,
1phase 2wires. 
60 Hz

Terminal 

block 1

Remark:

*  A disconnect switch 

should be required. 
Check the local code.

**  Use a ring tongue termi-

nal in order to connect a 
ground wire to terminal.

Terminal block 2

Electrical cover

Electrical box

Display panel

Conduit pipe
(for rear piping)

Conduit plate

or

3-3/8 in.
(85 mm)

2-3/8 in.
(60 mm)

Wall

Grounding  
terminal

Summary of Contents for MSZ-HE09NA

Page 1: ...s dust blockage or loose parts on the power supply plug or the outlet it could cause electric shock or fire If loose parts are found on the power supply plug replace it N Securely attach the electrical cover to the indoor unit and the service panel to the outdoor unit If the electrical cover of the indoor unit and or the service panel of the outdoor unit are not attached securely dust water etc cou...

Page 2: ...nlight Do not ex pose to direct sunlight also during the period following unpacking to before use Where it can be easily drained At a distance 3 ft 1 m or more away from a TV and radio Operation of the air conditioner may interfere with radio or TV reception An amplifier may be re quired for the affected device In a place as far away as possible from fluorescent and incandescent lights so the infr...

Page 3: ...g piping perform COOL operation for 30 minutes and pump down before removing the old air conditioner Remake flare according to the dimension for new refrigerant Note 1 Place indoor outdoor unit connecting wire A and power supply cord K at least 3 ft 1 m away from the TV antenna wire 4 in 100 mm or more 14 in 350 mm or more 8 in 200 mm 3 or more 2 4 in 100 mm or more when front and sides of unit are...

Page 4: ...end of indoor outdoor unit connecting wire A Fig 3 Attach it to the terminal block Be careful not to make mis wiring Attach the wire to the terminal block securely so that its core cannot be seen and no external force affects the connecting section of the terminal block 8 Firmly tighten the terminal screws After tightening verify that the wires are tightly fas tened 9 Reinstall conduit plate condu...

Page 5: ...the section to which the drain hose is to be attached at the rear of the indoor unit Fig 3 Insert a screwdriver into the hole on the cap and insert the cap fully into the drain pan 5 Insert the drain hose fully into the drain pan at the back right of the indoor unit Fig 4 Check if the hose is hooked securely to the projection of its inserting part at the drain pan 6 Insert the drain hose into wall...

Page 6: ...fective cut off the section and repeat procedure Conduit cover Lead wire 3 OUTDOOR UNIT INSTALLATION Power supply cord K Indoor outdoor unit connecting wire A Make earth wire a little longer than oth ers More than 2 3 8 in 60 mm For future servicing leave some slack in the connecting wires Be sure to attach each screw to its cor respondent terminal when securing the cord and or the wire to the ter...

Page 7: ...r turn on the breaker 2 Press the E O SW once Test run will be performed for 30 minutes If the power lamp blinks every 0 5 seconds inspect the indoor outdoor unit connecting wire A After the test run emergency COOL mode 75ºF 24ºC COOL will start 3 To stop operation press the E O SW several times until all LED lamps turn off Refer to operating instructions for details Checking the remote infrared s...

Page 8: ...veral times until all LED lamps turn off Refer to operating instructions for details 5 RELOCATION AND MAINTENANCE 5 1 REMOVING AND INSTALLING THE PANEL ASSEMBLY Removal procedure 1 Remove the two screws that attach the panel assembly 2 Remove the panel assembly Be sure to remove its bottom end first 5 2 REMOVING THE INDOOR UNIT Remove the bottom of the indoor unit from the installation plate When r...

Reviews: