background image

En-1

● OPERATING INSTRUCTIONS ●

C

ONTENTS

S

AFETY PRECAUTIONS

n

 SAFETY PRECAUTIONS 

1

n

 NAME OF EACH PART 

3

n

 PREPARATION BEFORE OPERATION 

4

n

 SELECTING OPERATION MODES 

5

n

  FAN SPEED AND AIRFLOW DIRECTION ADJUSTMENT 

6

n

 ECONO COOL OPERATION  

6

n

 TIMER OPERATION (ON/OFF TIMER) 

6

n

 DEMAND RESPONSE AND INDOOR UNIT OPERATION 

7

n

 EMERGENCY OPERATION 

7

n

 AUTO RESTART FUNCTION  

7

n

 CLEANING 

8

n

 WHEN YOU THINK THAT TROUBLE HAS OCCURRED 

9

n

 WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME 

10

n

 INSTALLATION PLACE AND ELECTRICAL WORK 

10

n

 SPECIFICATIONS 

10

 WARNING

Do not connect the power cord to an intermediate point, use an 
extension cord, or connect multiple devices to a single AC outlet.

•  This may cause overheating, fire, or electric shock.

Make sure the power plug is free of dirt and insert it securely 
into the outlet.

•  A dirty plug may cause fire or electric shock.

Do not bundle, pull, damage, or modify the power cord, and do 
not apply heat or place heavy objects on it.

•  This may cause fire or electric shock.

Do not turn the breaker OFF/ON or disconnect/connect the power 
plug during operation.

•  This may create sparks, which can cause fire.

•  After the indoor unit is switched OFF with the remote controller, 

make sure to turn the breaker OFF or disconnect the power plug. 

•  Since rotating parts and parts which could cause an electric shock are used 

in this product, be sure to read these “Safety Precautions” before use.

•  Since the cautionary items shown here are important for safety, be sure to 

observe them.

•  After reading this manual, keep it together with the installation manual in a 

handy place for easy reference.

•  Be sure to receive a guarantee card from your dealer and check that the 

purchased date and shop name, etc. are entered correctly.

Marks and their meanings

 WARNING :

Incorrect  handling  could  cause  serious  hazard,  such  as 

death, serious injury, etc. with a high probability.

 CAUTION :

Incorrect handling could cause serious hazard depending 

on the conditions.

Meanings of symbols used in this manual

 :  Be sure not to do.

 :  Be sure to follow the instruction.

 :  Never insert your finger or stick, etc.

 : 

Never step onto the indoor/outdoor unit and do not put anything on them.

 :  Danger of electric shock. Be careful.

 :  Be sure to disconnect the power supply plug from the power outlet.

 :  Be sure to shut off the power.

 :  Risk of fire.

Meanings of symbols displayed on indoor unit and/or outdoor unit

WARNING

(Risk of fire)

This unit uses a flammable refrigerant.

If refrigerant leaks and comes in contact with fire or heating part, it will create harmful gas and there is risk of fire.

Read the OPERATING INSTRUCTIONS carefully before operation.

Service personnel are required to carefully read the OPERATING INSTRUCTIONS and INSTALLATION MANUAL before operation.

Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION MANUAL, and the like.

Do not expose your body directly to cool air for a prolonged 
length of time.

•  This could be detrimental to your health.

The unit should not be installed, relocated, disassembled, 
altered, or repaired by the user.

•  An  improperly  handled  air  conditioner  may  cause  fire,  electric 

shock, injury, or water leakage, etc. Consult your dealer.

•  If the power supply cord is damaged, it must be replaced by the 

manufacturer or its service agent in order to avoid a hazard.

When installing, relocating, or servicing the unit, make sure that 

no substance other than the specified refrigerant (R32) enters 

the refrigerant circuit.

•  Any presence of foreign substance such as air can cause abnormal 

pressure rise and may result in explosion or injury.

• 

The use of any refrigerant other than that specified for the system will 

cause mechanical failure, system malfunction, or unit breakdown. In 

the worst case, this could lead to a serious impediment to securing 

product safety.

JG79Y822H02_en.indd   1

2021/03/25   8:58:14

Summary of Contents for MSZ-GS25VFD

Page 1: ...ONS For user To use this unit correctly and safely be sure to read these operating instructions before use MSZ GS25VFD MSZ GS35VFD MSZ GS50VFD MSZ GS60VFD MSZ GS71VFD MSZ GS80VFD INDOOR UNIT JG79Y822H02_Cover Helvetica_Neue_LT_Std indd 1 2021 03 25 8 59 38 ...

Page 2: ...se serious hazard such as death serious injury etc with a high probability CAUTION Incorrect handling could cause serious hazard depending on the conditions Meanings of symbols used in this manual Be sure not to do Be sure to follow the instruction Never insert your finger or stick etc Never step onto the indoor outdoor unit and do not put anything on them Danger of electric shock Be careful Be su...

Page 3: ... farms or for commercial use by lay persons CAUTION Do not touch the air inlet or the aluminum fins of the indoor outdoor unit This may cause injury Do not use insecticides or flammable sprays on the unit This may cause a fire or deformation of the unit Do not expose pets or houseplants to direct airflow This may cause injury to the pets or plants Do not place other electric appliances or furnitur...

Page 4: ... two or more indoor units are installed in proximity to one another an indoor unit that is not intended to be operated may respond to the remote controller Fan guard Operation indicator lamp Remote control receiving section Emergency operation switch Horizontal vane Vertical vane Air outlet Fan Fan guard Air filter Air inlet Heat exchanger Front panel Display section Emergency operation switch Pag...

Page 5: ...oller could malfunction Do not use rechargeable batteries Replace all batteries with new ones of the same type Batteries can be used for approximately 1 year However batteries with ex pired shelf lives last shorter Press RESET gently using a thin instrument If the RESET button is not pressed the remote controller may not operate correctly 2 Insert the negative pole of AAA alkaline batteries first ...

Page 6: ...ry low outside temperatures less than 10 C Water condensed in the unit may drip and wet or damage furni ture etc COOL mode DRY mode HEAT mode FAN mode Dehumidify your room The room may be cooled slightly Temperature cannot be set during DRY mode Enjoy warm air at your desired temperature Circulate the air in your room Note After COOL DRY mode operation it is recommended to operate in the FAN mode ...

Page 7: ...ration Note If the vertical vanes are adjusted while the unit is not operating be sure to return the horizontal vanes to the original closed position Left right Airflow direction ECONO COOL OPERATION Swing airflow change of air flow makes you feel cooler than stationary airflow The set temperature and the airflow direction are automatically changed by the microprocessor It is possible to perform c...

Page 8: ...tal electrical energy that would be consumed if operating at the rated capacity in a half hour period Note DRM is automatically activated or released according to the signals from DRED DRM cannot be invalidated or changed manually You might feel this unit does not sufficiently perform cooling or heating operation during DRM Operation settings can be changed as usual with the remote controller duri...

Page 9: ... Clean the filters regularly for best performance and to reduce power consumption Dirty filters cause condensation in the air conditioner which will contribute to the growth of fungi such as mold It is therefore recommended to clean air filters every 2 weeks Air filter Clean every 2 weeks Remove dirt by a vacuum cleaner or rinse with water After washing with water dry it well in shade Pull to remo...

Page 10: ...harged from the outdoor unit In the heating operation vapor generated by the defrosting operation looks like white smoke Remote controller The display on the remote controller does not appear or it is dim The indoor unit does not respond to the remote control signal Are the batteries exhausted Page 4 Is the polarity of the batteries correct Page 4 Are any buttons on the remote controller of other ...

Page 11: ...wall etc Inverter type fluorescent lamp Keep a space to prevent the picture distortion or the noise 1 m or more Radio 100 mm or more GS25 35 50 60 71 80 200 500 mm or more For the optimum efficiency and to extend the life time of using the outdoor unit should be installed in well ventilated dry place TV Cordless phone or Portable phone 3 m or more 1 m or more The installation location of the outdo...

Page 12: ...JG79Y822H02 HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN JG79Y822H02_Cover Helvetica_Neue_LT_Std indd 2 2021 03 25 8 59 38 ...

Reviews: