26
2. Check of Wi-Fi interface (MSZ-FT·VGK)
Follow the procedure below if the air conditioner cannot be monitored or controlled with a device such as a smartphone.
Connect the Wi-Fi interface and the router by referring to
SETUP QUICK REFERENCE GUIDE and SETUP MANUAL. If
the connection failed, check the following and connect the Wi-Fi
interface and the router again:
- Make sure that communication distance is not too far between
the Wi-Fi interface and the router. Move the router closer to the
Wi-Fi interface.
- Make sure that the router uses WPA2-AES encryption.
- Make sure that the number of the connected devices to the
router does not exceed the limit.
If NET LED is not blinking, the Wi-Fi interface and the router are
not communicating properly. Move the router and check wheth-
er the communication has been improved.
The following characters cannot be used with SSID, so please
change if you are using. [ " , ' , < , > , & ]
Communication between the Wi-Fi interface and the router (or
MELCloud) has been failed.
The following characters cannot be used with SSID, so please
change if you are using. [ " , ' , < , > , & ]
Refer to the SETUP MANUAL at the following URL.
http://www.melcloud.com/Support
Check the instruction manuals for the router and the device such as a
smartphone, and enable the Internet access.
Start
Is UNIT LED on the Wi-Fi interface
blinking?
Can the device such as a smartphone be connected
to the Internet through the router?
Has pairing of the Wi-Fi interface and the router
been successfully completed?
Is NET LED on the Wi-Fi interface blinking?
Is ERR LED on the Wi-Fi interface blinking?
If the problem persists, please hold down the RESET switch
of Wi-Fi interface for 2 seconds. And please go through this
procedure again from the beginning after a while.
Yes
Yes
Yes
Yes
No
No
No
No
No
Yes
There is a problem in communication between the air conditioner and
the Wi-Fi interface. Check whether the air conditioner can be oper-
ated with a remote controller.
If the air conditioner does not operate, Check indoor/outdoor connect-
ing wire and the power supply. (Check the indoor power P.C. board
and the indoor electronic control P.C. board)
If the indoor/outdoor wire is connected and the power supplied,
hold down the RESET switch of Wi-Fi interface for 2 seconds. The
communication with the air conditioner is normal if UNIT LED starts
blinking. (It may take a few minutes to blinking.)
If the problem persists, check the cable and the connector of Wi-Fi
interface.
If all else failed, replace the Wi-Fi interface.
If not improve it even if replace the Wi-Fi interface, replace the indoor
electronic control P.C. board.